Effect of thermoelectric subcooling on COP and energy consumption of a propane heat pump

被引:5
作者
Aranguren, P. [1 ,2 ]
Sanchez, D. [3 ]
Haida, M. [4 ]
Smolka, J. [4 ]
Cabello, R. [3 ]
Rodriguez, A. [1 ,2 ]
Astrain, D. [1 ,2 ]
机构
[1] Univ Publ Navarra, Engn Dept, Arrosadia Campus, Pamplona 31006, Spain
[2] Univ Publ Navarra, Inst Smart Cities, Arrosadia Campus, Pamplona 31006, Spain
[3] Jaume I Univ, Dep Mech Engn & Construct, Campus Riu Sec s-n, E-12071 Castellon de La Plana, Spain
[4] Silesian Tech Univ, Dept Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
关键词
Propane; Heat pump; thermoelectric subcooler; COP enhancement; Energy savings; REFRIGERATION CYCLE;
D O I
10.1016/j.applthermaleng.2024.124242
中图分类号
O414.1 [热力学];
学科分类号
摘要
The building sector has an important impact on the environment, being responsible for 30 % of the total greenhouse gas emissions. Knowing that the energy consumption devoted to HVAC systems accounts for 50 % of the total energy consumption of buildings, it is paramount to develop environmentally friendly technologies able to provide green space heating to the building sector. To that purpose, this manuscript presents a computational study on propane vapor compression heat pumps which include thermoelectric subcooling to boost their operation. The combination of these technologies has been proven in the past to be very beneficial for refrigeration systems and this study concludes for the first time that propane heat pumps can highly benefit from thermoelectric subcooling. The widely conducted research includes the following parameters: ambient temperatures from -20 to 15 degrees C, voltage supplies to the thermoelectric modules from 0.5 to 10 VDC, number of thermoelectric subcooling blocks from 1 to 8 and two water inlet temperatures, 40 and 55 degrees C to study their influence on heating capacity, compressor and thermoelectric power consumptions, subcooling degree, propane mass flow, compressor capacity, COP, energy consumption and SCOP of the combined heat pump. The obtained results are very conclusive, COP enhancements up to 12.29 % are achieved when a thermoelectric subcooler with 16 modules is included in a propane heat pump already provided with an internal heat exchanger for an ambient temperature of -20 degrees C and a water inlet temperature of 55 degrees C. Additionally, improvements in Seasonal COP up to 9.98 % are achieved if the above-mentioned technologies integration between a vapor compression heat pump and a thermoelectric subcooler substitutes a conventional propane heat pump with an internal heat exchanger for space heating a single-story two-family house.
引用
收藏
页数:16
相关论文
共 33 条
[1]  
[Anonymous], 2011, WORLD ENERGY OUTLOOK
[2]   Experimental assessment of a thermoelectric subcooler included in a transcritical CO2 refrigeration plant [J].
Aranguren, P. ;
Sanchez, D. ;
Casi, A. ;
Cabello, R. ;
Astrain, D. .
APPLIED THERMAL ENGINEERING, 2021, 190
[3]   Improvements in the cooling capacity and the COP of a transcritical CO2 refrigeration plant operating with a thermoelectric subcooling system [J].
Astrain, D. ;
Merino, A. ;
Catalan, L. ;
Aranguren, P. ;
Araiz, M. ;
Sanchez, D. ;
Cabello, R. ;
Llopis, R. .
APPLIED THERMAL ENGINEERING, 2019, 155 :110-122
[4]   Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270 [J].
Cabello, Ramon ;
Sanchez, Daniel ;
Llopis, Rodrigo ;
Andreu-Nacher, Alejandro ;
Calleja-Anta, Daniel .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 137 :22-33
[5]   Experimental evaluation of a transcritical CO2 refrigeration facility working with an internal heat exchanger and a thermoelectric subcooler: Performance assessment and comparative [J].
Casi, Alvaro ;
Aranguren, Patricia ;
Araiz, Miguel ;
Sanchez, Daniel ;
Cabello, Ramon ;
Astrain, David .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 141 :66-75
[6]   Experimental validation and development of an advanced computational model of a transcritical carbon dioxide vapour compression cycle with a thermoelectric subcooling system [J].
Casi, Alvaro ;
Aranguren, Patricia ;
Sanchez, Daniel ;
Araiz, Miguel ;
Cabello, Ramon ;
Astrain, David .
APPLIED THERMAL ENGINEERING, 2022, 206
[7]   Experimental investigation on an auto-cascade quasi two-stage compression heat pump system [J].
Cui, Mengdi ;
Cheng, Zuo ;
Wang, Baolong ;
Wei, Falin ;
Shi, Wenxing .
APPLIED THERMAL ENGINEERING, 2023, 219
[8]   Thermodynamic performance evaluation of transcritical carbon dioxide refrigeration cycle integrated with thermoelectric subcooler and expander [J].
Dai, Baomin ;
Liu, Shengchun ;
Zhu, Kai ;
Sun, Zhili ;
Ma, Yitai .
ENERGY, 2017, 122 :787-800
[9]  
energyplus, EnergyPlus Weather Converter
[10]  
Ermakov A, 2023, EDP Sciences, V459, DOI [10.1051/e3sconf/202345907003, DOI 10.1051/E3SCONF/202345907003]