Fourier-domain-compressed optical time-stretch quantitative phase imaging flow cytometry

被引:0
作者
Li, Rubing [1 ]
Weng, Yueyun [1 ,2 ]
Wei, Shubin [1 ]
Lin, Siyuan [1 ]
Huang, Jin [1 ]
Song, Congkuan [3 ]
Shen, Hui [4 ]
Hou, Jinxuan [5 ]
Xu, Yu [6 ]
Mei, Liye [1 ,7 ]
Wang, Du [1 ]
Zou, Yujie [8 ]
Yin, Tailang [8 ]
Zhou, Fuling [4 ]
Geng, Qing [3 ]
Liu, Sheng [1 ,2 ]
Lei, Cheng [1 ,9 ,10 ]
机构
[1] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Peoples R China
[3] Wuhan Univ, Renmin Hosp, Dept Thorac Surg, Wuhan 430060, Peoples R China
[4] Wuhan Univ, Zhongnan Hosp, Dept Hematol, Wuhan 430071, Peoples R China
[5] Wuhan Univ, Zhongnan Hosp, Dept Thyroid & Breast Surg, Wuhan 430071, Peoples R China
[6] Wuhan Univ, Zhongnan Hosp, Dept Radiat & Med Oncol, Wuhan 430071, Peoples R China
[7] Hubei Univ Technol, Sch Comp Sci, Wuhan 430068, Peoples R China
[8] Wuhan Univ, Renmin Hosp, Reprod Med Ctr, Wuhan 430060, Peoples R China
[9] Wuhan Univ, Suzhou Inst, Suzhou 215000, Peoples R China
[10] Wuhan Univ, Shenzhen Inst, Shenzhen 518057, Peoples R China
关键词
HIGH-THROUGHPUT; CELL;
D O I
10.1364/PRJ.523653
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical time-stretch (OTS) imaging flow cytometry offers a promising solution for high-throughput and highprecision cell analysis due to its capabilities of high-speed, high-quality, and continuous imaging. Compressed sensing (CS) makes it practically applicable by significantly reducing the data volume while maintaining its highspeed and high-quality imaging properties. To enrich the information of the images acquired with CS-equipped OTS imaging flow cytometry, in this work we propose and experimentally demonstrate Fourier-domain- compressed OTS quantitative phase imaging flow cytometry. It is capable of acquiring intensity and quantitative phase images of cells simultaneously from the compressed data. To evaluate the performance of our method, static microparticles and a corn root cross section are experimentally measured under various compression ratios. Furthermore, to show how our method can be applied in practice, we utilize it in the drug response analysis of breast cancer cells. Experimental results show that our method can acquire high-quality intensity and quantitative phase images of flowing cells at a flowing speed of 1 m/s and a compression ratio of 30%. Combined with machine-learning-based image analysis, it can distinguish drug-treated and drug-untreated cells with an accuracy of over 95%. We believe our method can facilitate cell analysis in both scientific research and clinical settings where both high-throughput and high-content cell analysis is required. (c) 2024 Chinese Laser Press
引用
收藏
页码:1627 / 1639
页数:13
相关论文
共 37 条
  • [1] Quantitative phase microscopy for non-invasive live cell population monitoring
    Aknoun, Sherazade
    Yonnet, Manuel
    Djabari, Zied
    Graslin, Fanny
    Taylor, Mark
    Pourcher, Thierry
    Wattellier, Benoit
    Pognonec, Philippe
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] The PARP inhibitor AZD2281 (Olaparib) induces autophagy/mitophagy in BRCA1 and BRCA2 mutant breast cancer cells
    Arun, Banu
    Akar, Ugur
    Gutierrez-Barrera, Angelica M.
    Hortobagyi, Gabriel N.
    Ozpolat, Bulent
    [J]. INTERNATIONAL JOURNAL OF ONCOLOGY, 2015, 47 (01) : 262 - 268
  • [3] High-speed flow microscopy using compressed sensing with ultrafast laser pulses
    Bosworth, Bryan T.
    Stroud, Jasper R.
    Tran, Dung N.
    Tran, Trac D.
    Chin, Sang
    Foster, Mark A.
    [J]. OPTICS EXPRESS, 2015, 23 (08): : 10521 - 10532
  • [4] Deep Learning in Label-free Cell Classification
    Chen, Claire Lifan
    Mahjoubfar, Ata
    Tai, Li-Chia
    Blaby, Ian K.
    Huang, Allen
    Niazi, Kayvan Reza
    Jalali, Bahram
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [5] Digital holography for quantitative phase-contrast imaging
    Cuche, E
    Bevilacqua, F
    Depeursinge, C
    [J]. OPTICS LETTERS, 1999, 24 (05) : 291 - 293
  • [6] Circulating tumor cell isolation for cancer diagnosis and prognosis
    Deng, Zicheng
    Wu, Shengming
    Wang, Yilong
    Shi, Donglu
    [J]. EBIOMEDICINE, 2022, 83
  • [7] Fast wide-field photothermal and quantitative phase cell imaging with optical lock-in detection
    Eldridge, Will J.
    Meiri, Amihai
    Sheinfeld, Adi
    Rinehart, Matthew T.
    Wax, Adam
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (08): : 2517 - 2526
  • [8] High-throughput optical coherence tomography at 800 nm
    Goda, Keisuke
    Fard, Ali
    Malik, Omer
    Fu, Gilbert
    Quach, Alan
    Jalali, Bahram
    [J]. OPTICS EXPRESS, 2012, 20 (18): : 19612 - 19617
  • [9] The prognostic and therapeutic implications of circulating tumor cell phenotype detection based on epithelial-mesenchymal transition markers in the first-line chemotherapy of HER2-negative metastatic breast cancer
    Guan, Xiuwen
    Ma, Fei
    Li, Chunxiao
    Wu, Shiyang
    Hu, Shangying
    Huang, Jiefen
    Sun, Xiaoying
    Wang, Jiayu
    Luo, Yang
    Cai, Ruigang
    Fan, Ying
    Li, Qiao
    Chen, Shanshan
    Zhang, Pin
    Li, Qing
    Xu, Binghe
    [J]. CANCER COMMUNICATIONS, 2019, 39
  • [10] Optofluidic time-stretch quantitative phase microscopy
    Guo, Baoshan
    Lei, Cheng
    Wu, Yi
    Kobayashi, Hirofumi
    Ito, Takuro
    Yalikun, Yaxiaer
    Lee, Sangwook
    Isozaki, Akihiro
    Li, Ming
    Jiang, Yiyue
    Yasumoto, Atsushi
    Di Carlo, Dino
    Tanaka, Yo
    Yatomi, Yutaka
    Ozeki, Yasuyuki
    Goda, Keisuke
    [J]. METHODS, 2018, 136 : 116 - 125