Experimental investigation on the horizontal impact response of precast RC bridge piers with grouted sleeve connections considering defects

被引:2
作者
He, An [1 ,2 ]
Zheng, Dun-Cong [1 ,2 ]
Cai, Jian [1 ,2 ]
Chen, Qing-Jun [1 ,2 ]
Tang, Xu-Lin [3 ]
Ye, Jia-Bin [1 ,3 ]
机构
[1] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510641, Peoples R China
[2] South China Univ Technol, State Key Lab Subtrop Bldg & Urban Sci, Guangzhou 510641, Peoples R China
[3] Guangzhou Jishi Construction Grp Co Ltd, Guangzhou 510115, Peoples R China
基金
中国国家自然科学基金;
关键词
Grouted sleeve connection; Impact test; Precast bridge pier; Grouting defect; Dynamic performance; SPLICE; PERFORMANCE; BEHAVIOR; COLUMNS;
D O I
10.1016/j.engstruct.2024.118617
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the behaviour of precast bridge piers with grouted sleeve connections under horizontal lowvelocity impact loads, twelve precast reinforced concrete (RC) bridge pier specimens and two cast-in-place reference specimens were tested to study the effect of grouting defect degree, impact velocity and fabricated method (precast vs. cast-in-place) on the impact response of RC piers. The failure modes, rebar strains, impact forces, displacement, and energy dissipation capacity of both cast-in-place and precast specimens were compared and analyzed. The results indicate that due to inertial effects induced by impact loading, the peak impact forces were three to seven times greater than the peak static loads. Transverse cracks were more likely to initiate in the grout layer for precast specimens, with diagonal cracks extending from the loading position to the pier bottom after impact. As horizontal impact velocity increased, the impact force, maximum displacement, and energy absorption ratio also significantly increased. The impact force-time curves of the pier specimens with grouting fullness ranging from 30 % to 100 % showed minimal differences compared to the cast-in-place specimen. A decrease in grouting fullness led to an increase in the maximum displacement of the pier specimens and reduced the transmission of impact waves between the reinforcement bars.
引用
收藏
页数:13
相关论文
共 29 条
  • [1] Performance of hollow-core FRP-concrete-steel bridge columns subjected to vehicle collision
    Abdelkarim, Omar I.
    ElGawady, Mohamed A.
    [J]. ENGINEERING STRUCTURES, 2016, 123 : 517 - 531
  • [2] [Anonymous], 2015, JGJ355-2015
  • [3] [Anonymous], 2017, AASHTO LRFD BRIDG DE
  • [4] [Anonymous], 2015, General Specifications for Design of Highway Bridges and Culverts
  • [5] Dynamic behaviour of axially-loaded RC columns under horizontal impact loading
    Cai, Jian
    Ye, Jia-Bin
    Chen, Qing-Jun
    Liu, Xinpei
    Wang, Yong-Qi
    [J]. ENGINEERING STRUCTURES, 2018, 168 : 684 - 697
  • [6] Experimental investigation of mechanical properties of steel half-grouted sleeve splice with rebar bonding defects
    Chen, Jianwei
    Wang, Zhanwen
    Liu, Ziye
    Ju, Shilong
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [7] Haber ZB, 2014, ACI STRUCT J, V111, P639
  • [8] Damage Assessment of Simply Supported Double-Pier Bent Bridge under Heavy Truck Collision
    Heng, Kai
    Li, Ruiwen
    Wu, Hao
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2022, 27 (05)
  • [9] Feasibility study of grouted splice connector under tensile load
    Hua, Ling Jen
    Rahman, Ahmad Baharuddin Abd
    Ibrahim, Izni Syahrizal
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 50 : 530 - 539
  • [10] Numerical study on the influence of defects in grouting on the mechanical properties of a full grouted sleeve connector
    Kahama, Espoir Kulondwa
    Fuzhe, Xie
    Anglaaere, Desmond-Luke M.
    [J]. JOURNAL OF ADHESION, 2022, 98 (16) : 2550 - 2581