Numerical simulation in magnetic resonance imaging radiofrequency dosimetry

被引:0
|
作者
Subaar, Christiana [1 ]
Gyan, Emmanuel [2 ]
Dompreh, Kwadwo A. [3 ]
Amoako, Joseph K. [4 ]
Edusei, George [5 ]
Owusu, Alfred [3 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Phys, Kumasi, Ghana
[2] Sunyani Tech Univ, Fac Appl Sci, Dept Pharmaceut Sci, Sunyani, Ghana
[3] Univ Cape Coast, Dept Phys, Cape Coast, Ghana
[4] Ghana Atom Energy Commiss GAEC, Radiat Protect Inst, Accra, Ghana
[5] Univ Environm & Sustainable Dev, Somanya, Ghana
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2024年 / 10卷 / 05期
关键词
electromagnetic field; in-vivo; invasive; radiofrequency; temperature; ELECTROMAGNETIC-FIELDS; MR PROCEDURES; HUMAN HEAD; TEMPERATURE; EXPOSURE; BODY; MULTIREGION; ABSORPTION;
D O I
10.1088/2057-1976/ad6a68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) employs a radiofrequency electromagnetic field to create pictures on a computer. The prospective biological consequences of exposure to radiofrequency electromagnetic fields (RF EMFs) have not yet been demonstrated, and there is not enough evidence on biological hazards to offer a definite response concerning possible RF health dangers. Therefore, it is crucial to research the health concerns in reaction to RF EMFs, considering the entire exposure in terms of patients receiving MRI. Monitoring increases in temperature in-vivo throughout MRI scan is extremely invasive and has resulted in a rise in the utilization of computational methods to estimate distributions of temperatures. The purpose of this study is to estimate the absorbed power of the brain exposed to RF in patients undergoing brain MRI scan. A three-dimensional Penne's bio-heat equation was modified to computationally analyze the temperature distributions and potential thermal effects within the brain during MRI scans in the 0.3 T to 1.5 T range (12.77 MHz to 63.87 MHz). The instantaneous temperature distributions of the in-vivo tissue in the brain temperatures measured at a time, t = 20.62 s is 0.2 degrees C and t = 30.92 s is 0.4 degrees C, while the highest temperatures recorded at 1.03 min and 2.06 min were 0.4 degrees C and 0.6 degrees C accordingly. From the temperature distributions of the in-vivo tissue in the brain temperatures measured, there is heat build-up in patients who are exposed to electromagnetic frequency ranges, and, consequently, temperature increases within patients are difficult to prevent. The study has, however, indicated that lengthier imaging duration appears to be related to increasing body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Fetal magnetic resonance imaging: exposure times and functional outcomes at preschool age
    Bouyssi-Kobar, Marine
    du Plessis, Adre J.
    Robertson, Richard L.
    Limperopoulos, Catherine
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1823 - 1830
  • [42] A Physical Framework to Interpret the Effects of High Permittivity Materials on Radiofrequency Coil Performance in Magnetic Resonance Imaging
    Ruello, Giuseppe
    Lattanzi, Riccardo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (11) : 3278 - 3287
  • [43] Metabolic Magnetic Resonance Imaging in Neuroimaging: Magnetic Resonance Spectroscopy, Sodium Magnetic Resonance Imaging and Chemical Exchange Saturation Transfer
    Hampton, Daniel G.
    Goldman-Yassen, Adam E.
    Sun, Phillip Zhe
    Hu, Ranliang
    SEMINARS IN ULTRASOUND CT AND MRI, 2021, 42 (05) : 452 - 462
  • [44] A magnetic resonance imaging, histological, and dose modeling comparison of focused ultrasound, radiofrequency, and Gamma Knife radiosurgery lesions in swine thalamus Laboratory investigation
    Elias, W. Jeff
    Khaled, Mohamad
    Hilliard, Justin D.
    Aubry, Jean-Francois
    Frysinger, Robert C.
    Sheehan, Jason P.
    Wintermark, Max
    Lopes, Maria Beatriz
    JOURNAL OF NEUROSURGERY, 2013, 119 (02) : 307 - 317
  • [45] Magnetic Resonance Imaging of the Spine
    Cousins, Joseph P.
    Haughton, Victor M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (01) : 22 - 30
  • [46] Magnetic resonance imaging of the skin
    Stefanowska, J.
    Zakowiecki, D.
    Cal, K.
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2010, 24 (08) : 875 - 880
  • [47] Magnetic resonance imaging of glutamate
    Cai, Kejia
    Haris, Mohammad
    Singh, Anup
    Kogan, Feliks
    Greenberg, Joel H.
    Hariharan, Hari
    Detre, John A.
    Reddy, Ravinder
    NATURE MEDICINE, 2012, 18 (02) : 302 - 306
  • [48] Biological Effects and Safety in Magnetic Resonance Imaging: A Review
    Hartwig, Valentina
    Giovannetti, Giulio
    Vanello, Nicola
    Lombardi, Massimo
    Landini, Luigi
    Simi, Silvana
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2009, 6 (06) : 1778 - 1798
  • [49] Magnetic resonance cavitation imaging for the monitoring of ultrasound therapies
    Ishak, Ounay
    Breton, Elodie
    Cabras, Paolo
    Dumont, Erik
    Mondou, Paul
    Novell, Anthony
    Larrat, Benoit
    Vappou, Jonathan
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21)
  • [50] Exposure Guidelines for Magnetic Resonance Imaging: The Most Successful Application of Electromagnetics in Biology and Medicine
    Lin, James C.
    IEEE MICROWAVE MAGAZINE, 2011, 12 (04) : 46 - 56