Numerical simulation in magnetic resonance imaging radiofrequency dosimetry

被引:0
|
作者
Subaar, Christiana [1 ]
Gyan, Emmanuel [2 ]
Dompreh, Kwadwo A. [3 ]
Amoako, Joseph K. [4 ]
Edusei, George [5 ]
Owusu, Alfred [3 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Phys, Kumasi, Ghana
[2] Sunyani Tech Univ, Fac Appl Sci, Dept Pharmaceut Sci, Sunyani, Ghana
[3] Univ Cape Coast, Dept Phys, Cape Coast, Ghana
[4] Ghana Atom Energy Commiss GAEC, Radiat Protect Inst, Accra, Ghana
[5] Univ Environm & Sustainable Dev, Somanya, Ghana
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2024年 / 10卷 / 05期
关键词
electromagnetic field; in-vivo; invasive; radiofrequency; temperature; ELECTROMAGNETIC-FIELDS; MR PROCEDURES; HUMAN HEAD; TEMPERATURE; EXPOSURE; BODY; MULTIREGION; ABSORPTION;
D O I
10.1088/2057-1976/ad6a68
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) employs a radiofrequency electromagnetic field to create pictures on a computer. The prospective biological consequences of exposure to radiofrequency electromagnetic fields (RF EMFs) have not yet been demonstrated, and there is not enough evidence on biological hazards to offer a definite response concerning possible RF health dangers. Therefore, it is crucial to research the health concerns in reaction to RF EMFs, considering the entire exposure in terms of patients receiving MRI. Monitoring increases in temperature in-vivo throughout MRI scan is extremely invasive and has resulted in a rise in the utilization of computational methods to estimate distributions of temperatures. The purpose of this study is to estimate the absorbed power of the brain exposed to RF in patients undergoing brain MRI scan. A three-dimensional Penne's bio-heat equation was modified to computationally analyze the temperature distributions and potential thermal effects within the brain during MRI scans in the 0.3 T to 1.5 T range (12.77 MHz to 63.87 MHz). The instantaneous temperature distributions of the in-vivo tissue in the brain temperatures measured at a time, t = 20.62 s is 0.2 degrees C and t = 30.92 s is 0.4 degrees C, while the highest temperatures recorded at 1.03 min and 2.06 min were 0.4 degrees C and 0.6 degrees C accordingly. From the temperature distributions of the in-vivo tissue in the brain temperatures measured, there is heat build-up in patients who are exposed to electromagnetic frequency ranges, and, consequently, temperature increases within patients are difficult to prevent. The study has, however, indicated that lengthier imaging duration appears to be related to increasing body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] EMF assessment: new aspects in numerical dosimetry for the simulation of human body models
    Ueberbacher, Richard
    Cecil, Stefan
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2020, 137 (02): : 83 - 92
  • [32] A numerical simulation method for aircraft infrared imaging
    Zhou, Yue
    Wang, Qiang
    Li, Ting
    Hu, Haiyang
    INFRARED PHYSICS & TECHNOLOGY, 2017, 83 : 68 - 77
  • [33] Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging
    Li, Zhen
    Vogel, Martin
    Maccarini, Paolo F.
    Stakhursky, Vadim
    Soher, Brian J.
    Craciunescu, Oana I.
    Das, Shiva
    Arabe, Omar A.
    Joines, Williams T.
    Stauffer, Paul R.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (01) : 86 - 99
  • [34] Numerical Computation Methods for Evaluating the Electromagnetic Safety of Magnetic Resonance Imaging System
    Niu C.
    Wang Q.
    Li Y.
    Tang W.
    Hu Y.
    Zhu X.
    Wang, Qiuliang (qiuliang@mail.iee.ac.cn), 1600, Science Press (43): : 2442 - 2453
  • [35] Measurement of thermal diffusivity by magnetic resonance imaging
    Gultekin, David H.
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (09) : 1203 - 1207
  • [36] Imaging of atherosclerosis: magnetic resonance imaging
    Corti, Roberto
    Fuster, Valentin
    EUROPEAN HEART JOURNAL, 2011, 32 (14) : 1709 - U149
  • [37] Roles for magnetic resonance imaging in process tomography
    Hall, LD
    IEEE SENSORS JOURNAL, 2005, 5 (02) : 125 - 133
  • [38] Comparison of gross pathology inspection and 9.4 T magnetic resonance imaging in the evaluation of radiofrequency ablation lesions in the left ventricle of the swine heart
    Odehnalova, Eva
    Valikova, Lucia
    Caluori, Guido
    Kulik, Tomas
    Rimalova, Veronika
    Jadczyk, Tomasz
    Drazanova, Eva
    Pavlova, Iveta
    Pesl, Martin
    Kubes, Vaclav
    Starek, Zdenek
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [39] Health Effects and Safety of Magnetic Resonance Imaging
    de Vocht, Frank
    Wilen, Jonna
    Mild, Kjell Hansson
    van Nierop, Lotte E.
    Slottje, Pauline
    Kromhout, Hans
    JOURNAL OF MEDICAL SYSTEMS, 2012, 36 (03) : 1779 - 1780
  • [40] RF-Induced Heating of Various Tattoos at Magnetic Resonance Imaging Systems
    Hayat, Shahzeb
    Cho, Youngdae
    Oh, Sukhoon
    Yoo, Hyoungsuk
    IEEE ACCESS, 2021, 9 : 100951 - 100961