Endoscopic Endonasal Occipitocervical Fixation with a Customized Three-Dimensional Printed Titanium Plate-Screw Construct: A Cadaveric Feasibility Study

被引:0
|
作者
Kaye, Joel [1 ]
Na, John [1 ]
Stephan, Katarina [1 ]
Bal, Ella [1 ]
Nebor, Ivanna [1 ]
Bucherl, Sean [2 ]
Nauman, Eric [2 ]
Nasser, Rani [1 ]
Virojanapa, Justin [1 ]
Andaluz, Norberto [1 ]
Forbes, Jonathan A. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Neurol Surg, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Biomed Engn, Cincinnati, OH USA
关键词
Craniocervical junction; Endonasal; Occipitocervical fusion; Odontoidectomy; VENTRAL CRANIOCERVICAL JUNCTION; CRANIOVERTEBRAL JUNCTION; BIOMECHANICAL EVALUATION; RESECTION; PLACEMENT; STABILITY; EXPOSURE; C1-C2;
D O I
10.1016/j.wneu.2024.07.055
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the feasibility of a novel method for occipitocervical fixation (OCF) through the endonasal corridor. METHODS: Thin-cut computed tomography scans were obtained for 5 cadaveric specimens. Image segmentation was used to reconstruct 3D models of each O-C1 joint complex. Using computer-aided design software, plates were custom-designed to span each O-C1 joint, sit flush onto the bony surface, and accommodate screws. The final models were 3D-printed in titanium. For implantation, specimens were held in pin-fixation and registered to neuronavigation. A rigid 0o endoscope was used for endonasal visualization. An inverted U-shaped nasopharyngeal flap was raised to expose the occipital condyles and C1. The plates were introduced and fixed with bone screws. Computed tomography scans were obtained to assess screw accuracy and proximity to critical neurovascular structures. Screw entry points and trajectories were recorded. RESULTS: Endonasal OCF was performed on 5 cadaveric specimens. The mean starting point for occipital condyle screws was 6.17 mm lateral and 5.38 mm rostral to the medial O-C1 joint. Mean axial and sagittal trajectories were 7.98 degrees degrees and 6.71 degrees, degrees , respectively. The mean starting point for C1 screws was 16.11 mm lateral to the C1 anterior tubercle and 6.39 mm caudal to the medial O-C1 joint. Mean axial and sagittal trajectories were 10.97 degrees degrees and L 9.91 degrees , respectively. CONCLUSIONS: Endonasal OCF is technically and anatomically feasible. The application of this technique may allow for same-stage endonasal decompression and fixation, offering a minimally invasive alternative to current methods of fixation and advancing surgeons' ability to treat pathology of the craniovertebral junction. Next steps will focus on biomechanical testing.
引用
收藏
页码:E959 / E969
页数:11
相关论文
共 14 条
  • [1] Feasibility of Occipital Condyle Screw Placement for Occipitocervical Fixation A Cadaveric Study and Description of a Novel Technique
    Uribe, Juan S.
    Ramos, Edivin
    Vale, Fernando
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (08): : 540 - 546
  • [2] Three-dimensional finite element analysis of occipitocervical fixation using an anterior occiput-to-axis locking plate system: a pilot study
    Cai, Xianhua
    Yu, Yang
    Liu, Zhichao
    Zhang, Meichao
    Huang, Weibing
    SPINE JOURNAL, 2014, 14 (08) : 1399 - 1409
  • [3] Three-Dimensional Printed Model-Assisted Screw Installation in Treating Posterior Atlantoaxial Internal Fixation
    Yang, Minyi
    Zhang, Nannan
    Shi, Haodong
    Li, Hui
    Liu, Shichang
    Song, Zongrang
    Shan, Lequn
    Wu, Qining
    Hao, Dingjun
    SCIENTIFIC REPORTS, 2018, 8
  • [4] Biomechanical evaluation of Chinese customized three-dimensional printed titanium miniplate in the Lefort I osteotomy: A finite element analysis
    Li, Jiayi
    Xie, Qianyang
    Liu, Xiaohan
    Jiao, Zixian
    Yang, Chi
    HELIYON, 2022, 8 (12)
  • [5] A customized percutaneous three-dimensional-printed guide for scaphoid fixation versus a freehand technique: a comparative study
    Marcano-Fernandez, Francesc A.
    Berenguer, Alexandre
    Fillat-Goma, Ferran
    Corderch-Navarro, Sergi
    Camara-Cabrera, Jaume
    Sanchez-Flo, Ricard
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (10) : 1081 - 1087
  • [6] Evaluation of a Three-Dimensional Printed Guide and a Polyoxymethylene Thermoplastic Regulator for Percutaneous Pedicle Screw Fixation in Patients with Thoracolumbar Fracture
    Zhang, Ming
    Li, Jiayi
    Fang, Tao
    Zhao, Jiali
    Pan, Wei
    Wang, Xinhong
    Xu, Jin
    Zhou, Quan
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [7] Endoscopic Endonasal Approach for Clipping Anterior Communicating Artery Aneurysms From Cadaver Studies and Three-Dimensional Printed Models to a Clinical Case
    Qin, Kun
    Guo, Wenlong
    Zheng, Jiantao
    Tian, Ge
    Jiang, Hui
    Tang, Kai
    Shu, Hang
    Zhou, Dong
    Chen, Guangzhong
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (08) : 2854 - 2858
  • [8] Robotic Surgical Approach to the Mesial Temporal Region: A Preliminary Three-Dimensional Cadaveric Study of Technical Feasibility
    Akbas, Ahmet
    Tugcu, Bekir
    Eksi, M. Sakir
    Erkan, Buruc
    Canbolat, Cagri
    Pamir, M. Necmettin
    Gungor, Abuzer
    WORLD NEUROSURGERY, 2020, 144 : E40 - E52
  • [9] Fracture of Standard Titanium Mandibular Reconstruction Plates and Preliminary Study of Three-Dimensional Printed Reconstruction Plates
    Almansoori, Akram Abdo
    Choung, Han-Wool
    Kim, Bongju
    Park, Joo-Young
    Kim, Soung-Min
    Lee, Jong-Ho
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (01) : 153 - 166
  • [10] Three-dimensional-printed patient-specific Kirschner-wire guide for percutaneous fixation of undisplaced scaphoid fractures: a cadaveric study
    Salabi, Vincent
    Rigoulot, Guillaume
    Sautet, Alain
    Cambon-Binder, Adeline
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (07) : 692 - 696