Automated hyperpolarized 129 Xe gas generator for nuclear magnetic resonance spectroscopy and imaging applications

被引:1
|
作者
Hattori, Mineyuki [1 ]
Hiraga, Takashi [1 ]
Homma, Kazuhiro [1 ]
Ohtake, Norio [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Res Inst Mat & Chem Measurement, Natl Metrol Inst Japan NMIJ, Tsukuba, Ibaraki 3058565, Japan
[2] Toyoko Kagaku Co Ltd, Resaerch & Dev Div, Kawasaki, Kanagawa 2118502, Japan
来源
JOURNAL OF MAGNETIC RESONANCE OPEN | 2024年 / 20卷
关键词
Hyperpolarized; Xenon; Nuclear magnetic resonance; Magnetic resonance imaging; SPIN-EXCHANGE; XE-129; GAS; NMR; XENON; MRI; POLARIZATION; BEHAVIOR; TIME; FLOW;
D O I
10.1016/j.jmro.2024.100154
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a method and an apparatus for producing hyperpolarized (HP) Xe gas of high concentration without Xe condensation. The HP Xe generator works under atmospheric pressure and employs a quasi-continuous method to provide a continuous supply of HP Xe gas by adopting technologies for supplying a highly pure gas, a gas control system and precise pressure control. The apparatus has a glass cell containing solid Rb metal and solid Xe in vacuum at a low temperature and is heated so that the Xe becomes a gas and Rb exists in a gas- liquid mixture. Then a magnetic field is applied with laser beam irradiation to produce polarized Xe gas of high concentration. The device was evaluated using a 2T magnetic resonance imaging (MRI) scanner. Long-term experimental operation demonstrated the continuous collection of 30 ml syringes of HP Xe gas with a sufficient polarization rate for fast one scan acquisition. A practical device for the automated manufacture of HP 129 Xe gas was thus successfully developed.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Functionalized 129Xe contrast agents for magnetic resonance imaging
    Taratula, Olena
    Dmochowski, Ivan J.
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2010, 14 (01) : 97 - 104
  • [42] Quantification of Ventilation and Gas Uptake in Free-Breathing Mice With Hyperpolarized 129Xe MRI
    Loza, Luis A.
    Kadlecek, Stephen J.
    Pourfathi, Mehrdad
    Hamedani, Hooman
    Duncan, Ian F.
    Ruppert, Kai
    Rizi, Rahim R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2081 - 2091
  • [43] In vivo MR spectroscopy of hyperpolarized Xe-129 in rat brain
    Wakai, A
    Nakamura, K
    Kershaw, J
    Kanno, I
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 139 - 143
  • [44] 129Xe nuclear resonance scattering on solid Xe and 129Xe clathrate hydrate
    Klobes, B.
    Desmedt, A.
    Sergueev, I.
    Schmalzl, K.
    Hermann, R. P.
    EPL, 2013, 103 (03)
  • [45] Combining hyperpolarized 129Xe MR imaging and spectroscopy to noninvasively estimate pulmonary vascular resistance
    Costelle, Anna
    Lu, Junlan
    Leewiwatwong, Suphachart
    Westerhof, Berend
    Mummy, David
    Rajagopal, Sudarshan
    Driehuys, Bastiaan
    JOURNAL OF APPLIED PHYSIOLOGY, 2025, 138 (03) : 623 - 633
  • [46] Detection of radiation induced lung injury in rats using dynamic hyperpolarized 129Xe magnetic resonance spectroscopy
    Fox, Matthew S.
    Ouriadov, Alexei
    Thind, Kundan
    Hegarty, Elaine
    Wong, Eugene
    Hope, Andrew
    Santyr, Giles E.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [47] Continuously Infusing Hyperpolarized 129Xe into Flowing Aqueous Solutions Using Hydrophobic Gas Exchange Membranes
    Cleveland, Zackary I.
    Moeller, Harald E.
    Hedlund, Laurence W.
    Driehuys, Bastiaan
    JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (37) : 12489 - 12499
  • [48] Correlation of Lung Clearance Index with Hyperpolarized 129Xe Magnetic Resonance Imaging in Pediatric Subjects with Cystic Fibrosis
    Kanhere, Nikhil
    Couch, Marcus J.
    Kowalik, Krzysztof
    Zanette, Brandon
    Rayment, Jonathan H.
    Manson, David
    Subbarao, Padma
    Ratjen, Felix
    Santyr, Giles
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 196 (08) : 1073 - 1075
  • [49] Gradient echo imaging of flowing hyperpolarized nuclei:: theory and phantom studies on 129Xe dissolved in ethanol
    Johansson, E
    Svensson, J
    Månsson, S
    Petersson, JS
    Olsson, LE
    Golman, K
    Ståhlberg, F
    JOURNAL OF MAGNETIC RESONANCE, 2002, 159 (01) : 68 - 75
  • [50] Hyperpolarized noble gas magnetic resonance imaging of the animal lung: Approaches and applications
    Santyr, Giles E.
    Lam, Wilfred W.
    Parra-Robles, Juan M.
    Taves, Timothy M.
    Ouriadov, Alexei V.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)