Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center

被引:0
作者
Kim, Wook [1 ]
Jee, Tae Keun [2 ]
Yeon, Je Young [2 ]
Kim, Keon Ha [1 ]
Kim, Jong-Soo [2 ]
Jeon, Pyoung [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Radiol, Sch Med, Seoul 06351, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Dept Neurosurg, Sch Med, Seoul 06351, South Korea
关键词
endovascular coil embolization; intracranial aneurysm; target tetra detachable coil; CEREBRAL ANEURYSMS; CENTER EXPERIENCE; CLASSIFICATION; PREVENTION; OUTCOMES; TRIAL; ISAT;
D O I
10.3390/jcm13164940
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Target tetra detachable coils (TTDCs) aid in achieving effective framing during the coil embolization of small intracranial aneurysms by maintaining a tetrahedral conformation within the aneurysm sac. We aimed to report the initial experience of patients treated for intracranial aneurysms using TTDCs, with a specific focus on efficacy and safety. Methods: We retrospectively reviewed the medical records of 41 patients who underwent the coil embolization of intracranial aneurysms sized <= 10 mm with TTDCs between April and May 2023. Post-procedural angiographic and clinical results were reviewed. Results: Of the 46 aneurysms (45 unruptured and 1 ruptured), 33 (71.7%) were treated with the stent-assisted technique and 13 (28.3%) using the simple coil embolization technique. Post-procedural angiography showed complete occlusion in 41 aneurysms (89.1%), neck remnants in 1 (2.2%), and residual aneurysms in 4 (8.7%). The mean packing density was 34.7% (19.3-46.8%), with TTDC coil length comprising a mean of 88.5% of the total coil length. No major device- or procedure-related complications were observed. During the follow-up, 40 aneurysms (93.0%) demonstrated complete occlusion, while neck remnants were observed in 1 (2.3%), and residual aneurysms in 2 (4.7%). No cases of recanalization were observed. Conclusions: The TTDC is a safe and effective device for the endovascular treatment of intracranial aneurysms. Follow-up studies are required to establish long-term results.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Long-term Clinical and Angiographic Results of Neuroform Stent-Assisted Coil Embolization in Wide-Necked Intracranial Aneurysms
    Santillan, Alejandro
    Greenberg, Edward
    Patsalides, Athos
    Salvaggio, Kimberly
    Riina, Howard A.
    Gobin, Y. Pierre
    NEUROSURGERY, 2012, 70 (05) : 1232 - 1237
  • [32] Endovascular treatment of cerebral aneurysms using the Woven EndoBridge technique in a single center: preliminary results
    Lawson, Aimee
    Goddard, Tony
    Ross, Stuart
    Tyagi, Atul
    Deniz, Kenan
    Patankar, Tufail
    JOURNAL OF NEUROSURGERY, 2017, 126 (01) : 17 - 28
  • [33] Endovascular treatment of intracranial aneurysms using the Woven EndoBridge (WEB) device: retrospective analysis of a single center experience
    Kaya, Hasan E.
    Bakdik, Suleyman
    Keskin, Fatih
    Erdi, Mehmet F.
    Koc, Osman
    CLINICAL IMAGING, 2020, 59 (01) : 25 - 29
  • [34] Endovascular treatment of anterior circulation cerebral aneurysms by using guglielmi detachable coils: A 10-year single-center experience with special emphasis on the use of three-dimensional GDC
    Wolynski J.
    Mordasini P.
    Schroth G.
    Barth A.
    Seiler R.W.
    Remonda L.
    Clinical Neuroradiology, 2007, 17 (2): : 98 - 107
  • [35] Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling
    Kim, Hyun Sik
    Cho, Byung Moon
    Yoo, Chan Jong
    Choi, Dae Han
    Hyun, Dong Keun
    Shim, Yu Shik
    Song, Joon Ho
    Oh, Jae Keun
    Ahn, Jun Hyong
    Kim, Ji Hee
    Chang, In Bok
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2021, 64 (05) : 751 - 762
  • [36] Endovascular treatment of wide-necked intracranial aneurysms using the novel Contour Neurovascular System: a single-center safety and feasibility study
    Akhunbay-Fudge, Christopher Yusuf
    Deniz, Kenan
    Tyagi, Atul Kumar
    Patankar, Tufail
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (10) : 987 - 992
  • [37] The place for remodeling technique and stenting in the endovascular management of intracranial aneurysms: a single-center analysis from 2008 to 2010
    Pierot, Laurent
    Rajpal, Girish
    Kadziolka, Krzysztof
    Barbe, Coralie
    NEURORADIOLOGY, 2012, 54 (09) : 973 - 979
  • [38] Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center
    Briganti, Francesco
    Napoli, Manuela
    Leone, Giuseppe
    Marseglia, Mariano
    Mariniello, Giuseppe
    Caranci, Ferdinando
    Tortora, Fabio
    Maiuri, Francesco
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1683 - 1690
  • [39] Stent-Assisted Coil Embolization of Wide-Necked Intracranial Aneurysms Using a Semi-Deployment Technique: Angiographic and Clinical Outcomes in 31 Consecutive Patients
    Gao, X.
    Liang, G.
    Li, Z.
    Qu, H.
    Wei, X.
    INTERVENTIONAL NEURORADIOLOGY, 2010, 16 (04) : 385 - 393
  • [40] Clinical and angiographic outcomes following endovascular treatment of very small (3mm or smaller) intracranial aneurysm A single-center experience
    Liu, Yongsheng
    Wang, Feng
    Fu, Xiaochen
    Liu, Yongjian
    Zhang, Guodong
    Xu, Ke
    MEDICINE, 2017, 96 (37)