Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy

被引:1
|
作者
Abdollahi, Sara [1 ,2 ,9 ]
Mowlavi, Ali Asghar [3 ,8 ]
Yazdi, Mohammad Hadi Hadizadeh [1 ]
Ceberg, Sofie [4 ]
Aznar, Marianne Camille [5 ]
Tabrizi, Fatemeh Varshoee [6 ]
Salek, Roham [7 ]
Guckenberger, Matthias [2 ]
Tanadini-Lang, Stephanie [2 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad, Iran
[2] Univ Hosp Zurich, Dept Radiat Oncol, CH-8091 Zurich, Switzerland
[3] Hakim Sabzevari Univ, Dept Phys, Sabzevar, Iran
[4] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, England
[6] Reza Radiotherapy & Oncol Ctr, Dept Radiat Oncol, Mashhad, Iran
[7] Mashhad Univ Med Sci, Dept Radiat Oncol, Mashhad, Iran
[8] Univ Montreal, Dept Phys, Montreal, PQ, Canada
[9] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 30卷
关键词
Lung SBRT; Dynamic anthropomorphic phantom; End-to-end test; LUNG-TUMOR MOTION; MITIGATION; DOSIMETRY;
D O I
10.1016/j.phro.2024.100587
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management techniques are important to spare the healthy tissue adequately. However, they are complex and need dedicated quality assurance. The aim of this study was to create a dynamic phantom designed for quality assurance and to replicate a patient's size, anatomy, and tissue density. Materials and methods: A computed tomography (CT) scan of a cancer patient was used to create molds for the lungs, heart, ribs, and vertebral column via additive manufacturing. A pump system and software were developed to simulate respiratory dynamics. The extent of respiratory motion was quantified using a 4DCT scan. End- to-end tests were conducted to evaluate two motion management techniques for lung stereotactic body radiotherapy (SBRT). Results: The chest wall moved between 4 mm and 13 mm anteriorly and 2 mm to 7 mm laterally during the breathing. The diaphragm exhibited superior-inferior movement ranging from 5 mm to 16 mm in the left lung and 10 mm to 36 mm in the right lung. The left lung tumor displaced f 7 mm superior-inferiorly and anterior- posteriorly. The CT numbers were for lung:-716 f 108 HU (phantom) and-713 f 70 HU (patient); bone: 460 f 20 HU (phantom) and 458 f 206 HU (patient); soft tissue: 92 f 9 HU (phantom) and 60 f 25 HU (patient). The end-to-end testing showed an excellent agreement between the measured and the calculated dose for ion chamber and film dosimetry. Conclusions: The phantom is recommended for quality assurance, evaluating the institution's specific planning and motion management strategies either through end-to-end testing or as an external audit phantom.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A Novel Anthropomorphic Phantom Composed of Tissue-Equivalent Materials for Use in Experimental Radiotherapy: Design, Dosimetry and Biological Pilot Study
    Breslin, Thomas
    Paino, Jason
    Wegner, Marie
    Engels, Elette
    Fiedler, Stefan
    Forrester, Helen
    Rennau, Hannes
    Bustillo, John
    Cameron, Matthew
    Hausermann, Daniel
    Hall, Christopher
    Krause, Dieter
    Hildebrandt, Guido
    Lerch, Michael
    Schueltke, Elisabeth
    BIOMIMETICS, 2023, 8 (02)
  • [32] A high-resolution large-area detector for quality assurance in radiotherapy
    Oliveira, Andreia Maia
    Akkerman, Hylke B.
    Braccini, Saverio
    van Breemen, Albert J. J. M.
    Gelinck, Gerwin H.
    Heracleous, Natalie
    Leidner, Johannes
    Murtas, Fabrizio
    Peeters, Bart
    Silari, Marco
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [33] Microstrip plastic scintillating detector system for quality assurance in synchrotron microbeam radiotherapy
    Thevenet, F.
    Keshmiri, S.
    Degouttes, J.
    Livingstone, J.
    Lu, G. -n.
    Adam, J. -f.
    Pittet, P.
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [34] Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom
    Alzahrani, Meshal
    O'Hara, Christopher
    Bird, David
    Baldwin, Jack P. C.
    Naisbit, Mitchell
    Teh, Irvin
    Broadbent, David A.
    Al-Qaisieh, Bashar
    Johnstone, Emily
    Speight, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21):
  • [35] Redesigning Radiotherapy Quality Assurance: Opportunities to Develop an Efficient, Evidence-Based System to Support Clinical Trials-Report of the National Cancer Institute Work Group on Radiotherapy Quality Assurance
    Bekelman, Justin E.
    Deye, James A.
    Vikram, Bhadrasain
    Bentzen, Soren M.
    Bruner, Deborah
    Curran, Walter J., Jr.
    Dignam, James
    Efstathiou, Jason A.
    FitzGerald, T. J.
    Hurkmans, Coen
    Ibbott, Geoffrey S.
    Lee, J. Jack
    Merchant, Thomas E.
    Michalski, Jeff
    Palta, Jatinder R.
    Simon, Richard
    Ten Haken, Randal K.
    Timmerman, Robert
    Tunis, Sean
    Coleman, C. Norman
    Purdy, James
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (03): : 782 - 790
  • [36] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom" (vol 35, pg 5434, 2008)
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2345 - 2345
  • [37] Design of a Reconfigurable Quality Assurance Phantom for Verifying the Spatial Accuracy of Radiosurgery Treatments for Multiple Brain Metastases
    Cobi, Alban C.
    Gray, Luke
    Mittmann, Elizabeth R.
    Link, Steven B.
    Hanumara, Nevan C.
    Lyatskaya, Yulia
    Roche, Ellen
    Slocum, Alexander H.
    Zygmanski, Piotr
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2019, 13 (04):
  • [38] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    T. Aland
    T. Kairn
    J. Kenny
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 251 - 260
  • [39] Exploring the gamma surface: A new method for visualising modulated radiotherapy quality assurance results
    Peet, Samuel C.
    Yu, Liting
    Maxwell, Sarah
    Crowe, Scott B.
    Trapp, Jamie, V
    Kairn, Tanya
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 166 - 172
  • [40] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    Aland, T.
    Kairn, T.
    Kenny, J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 251 - 260