Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy

被引:1
|
作者
Abdollahi, Sara [1 ,2 ,9 ]
Mowlavi, Ali Asghar [3 ,8 ]
Yazdi, Mohammad Hadi Hadizadeh [1 ]
Ceberg, Sofie [4 ]
Aznar, Marianne Camille [5 ]
Tabrizi, Fatemeh Varshoee [6 ]
Salek, Roham [7 ]
Guckenberger, Matthias [2 ]
Tanadini-Lang, Stephanie [2 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad, Iran
[2] Univ Hosp Zurich, Dept Radiat Oncol, CH-8091 Zurich, Switzerland
[3] Hakim Sabzevari Univ, Dept Phys, Sabzevar, Iran
[4] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, England
[6] Reza Radiotherapy & Oncol Ctr, Dept Radiat Oncol, Mashhad, Iran
[7] Mashhad Univ Med Sci, Dept Radiat Oncol, Mashhad, Iran
[8] Univ Montreal, Dept Phys, Montreal, PQ, Canada
[9] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 30卷
关键词
Lung SBRT; Dynamic anthropomorphic phantom; End-to-end test; LUNG-TUMOR MOTION; MITIGATION; DOSIMETRY;
D O I
10.1016/j.phro.2024.100587
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management techniques are important to spare the healthy tissue adequately. However, they are complex and need dedicated quality assurance. The aim of this study was to create a dynamic phantom designed for quality assurance and to replicate a patient's size, anatomy, and tissue density. Materials and methods: A computed tomography (CT) scan of a cancer patient was used to create molds for the lungs, heart, ribs, and vertebral column via additive manufacturing. A pump system and software were developed to simulate respiratory dynamics. The extent of respiratory motion was quantified using a 4DCT scan. End- to-end tests were conducted to evaluate two motion management techniques for lung stereotactic body radiotherapy (SBRT). Results: The chest wall moved between 4 mm and 13 mm anteriorly and 2 mm to 7 mm laterally during the breathing. The diaphragm exhibited superior-inferior movement ranging from 5 mm to 16 mm in the left lung and 10 mm to 36 mm in the right lung. The left lung tumor displaced f 7 mm superior-inferiorly and anterior- posteriorly. The CT numbers were for lung:-716 f 108 HU (phantom) and-713 f 70 HU (patient); bone: 460 f 20 HU (phantom) and 458 f 206 HU (patient); soft tissue: 92 f 9 HU (phantom) and 60 f 25 HU (patient). The end-to-end testing showed an excellent agreement between the measured and the calculated dose for ion chamber and film dosimetry. Conclusions: The phantom is recommended for quality assurance, evaluating the institution's specific planning and motion management strategies either through end-to-end testing or as an external audit phantom.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Plastic scintillator sheets for quality assurance in electron Flash radiotherapy
    Morrocchi, Matteo
    Anzalone, Rebecca
    Cavalieri, Andrea
    Ciarrocchi, Esther
    Del Sarto, Damiano
    Di Martino, Fabio
    Ravera, Eleonora
    Bisogni, Maria Giuseppina
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3335 - S3337
  • [22] Quality Assurance in Radiotherapy (RT)-Specific Trials: Indian Scenario
    Mahata, A.
    Chakraborty, S.
    Mandal, S.
    Achari, R. B.
    Bhattacharyya, T.
    Mallick, I.
    Arunsingh, M.
    Chatterjee, S.
    CLINICAL ONCOLOGY, 2025, 38
  • [23] Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP)
    Jermoumi, M.
    Korideck, H.
    Bhagwat, M.
    Zygmanski, P.
    Makrigiogos, G. M.
    Berbeco, R. I.
    Cormack, R. C.
    Ngwa, W.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05): : 529 - 535
  • [24] A novel anthropomorphic breathing phantom with a pneumatic MR-safe actuator for tissue deformation studies during MRI and radiotherapy
    Wheatley, Morgan
    De Deene, Yves
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 43 - 55
  • [25] Cost-efficient anthropomorphic head phantom for quantitative image quality assessment in cone beam CT
    Wang, Yichao
    Dankelman, Jenny
    Ruijters, Danny
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06)
  • [26] Evaluation of a novel patient-specific quality assurance phantom for robotic single-isocentre, multiple-target stereotactic radiosurgery, and stereotactic radiotherapy
    Xu, Qianyi
    Vinogradskiy, Yevgeniy
    Grimm, Jimm
    Nie, Wei
    Dupre, Pamela
    Chawla, Ashish K.
    Bajaj, Gopal
    Yang, Haihua
    Lacouture, Tamara
    Fan, Jiajin
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1155): : 660 - 667
  • [27] Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans
    Soliman, Yasser S.
    El Gohary, M. I.
    Gawad, M. H. Abdel
    Amin, E. A.
    Desouky, O. S.
    APPLIED RADIATION AND ISOTOPES, 2017, 120 : 126 - 132
  • [28] Resistive electrode array (REA) for radiotherapy beam monitoring and quality assurance
    Zygmanski, Piotr
    Lima, Jason
    Liles, Arianna
    Zhang, Victoria
    Gineitaite, Indre
    Sajo, Erno
    Brivio, Davide
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (13):
  • [29] End-to-end test of an online adaptive treatment procedure in MR-guided radiotherapy using a phantom with anthropomorphic structures
    Elter, A.
    Dorsch, S.
    Mann, P.
    Runz, A.
    Johnen, W.
    Spindeldreier, C. K.
    Klueter, S.
    Karger, C. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [30] End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom
    Elter, A.
    Rippke, C.
    Johnen, W.
    Mann, P.
    Hellwich, E.
    Schwahofer, A.
    Dorsch, S.
    Buchele, C.
    Klueter, S.
    Karger, C. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24):