Estimating the Point-Spread-Function using 1 μm diameter microspheres for image restoration in biomedical multiphoton microscopy

被引:0
|
作者
Martin, Segolene [1 ]
Ajdenbaum, Julien [1 ]
Chouzenoux, Emilie [1 ]
Magnol, Laetitia [2 ]
Blanquet, Veronique [2 ]
Pesquet, Jean-Christophe [1 ]
Lefort, Claire [3 ]
机构
[1] Univ Paris Saclay, Ctr Vis Numer, Cent Supelec, INRIA, Gif Sur Yvette, France
[2] Univ Limoges, EpiMaCT Epidemiol Chron Dis Trop Zone, INSERM U1094, INRAE USC1501,IRD U270, 2 Rue Pr Descottes, Limoges, France
[3] Univ Limoges, XLIM Res Inst, UMR CNRS 7252, Limoges, France
来源
OPTICS, PHOTONICS, AND DIGITAL TECHNOLOGIES FOR IMAGING APPLICATIONS VIII | 2024年 / 12998卷
基金
欧洲研究理事会;
关键词
Multiphoton microscopy; PSF estimation; 1 mu m bead diameter; in situ characterization; image restoration;
D O I
10.1117/12.3016624
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Multiphoton microscopy (MPM) is an advanced imaging technique used in biological and biomedical research to visualize and study living tissues and cells with high resolution. It is particularly well -suited for deep tissue imaging, as it minimizes photodamage and provides improved penetration compared to traditional microscopy techniques like confocal microscopy. The Point Spread Function (PSF) plays a crucial role in multiphoton microscopy and describes how a point source of light is imaged as a spatial distribution in the microscope. Understanding the 3D PSF is essential for deconvolution and other post -processing techniques used to reconstruct 3D images from a stack of 2D images. The imaging of fluorescent beads used as point sources is a solution to evaluate the PSF. Usually, this strategy involves a bead of dimensions smaller than resolutions, typically with diameter of about less than 200 nm. However, in this setting, it is often complex to detect correctly the beads and thus to estimate accurately the PSF. We develop a computational solution for the PSF estimation based on the imaging of micro objects bigger than the resolution limit. We use fluorescent microspheres with a diameter of 1 mu m and estimate the PSF from the deformations observed in the image of these microspheres. A deconvolution strategy illustrates the performance of our method, where we successfully restore an unsliced whole striated skeletal muscle utilizing the PSF estimated with 1 mu m diameter beads.
引用
收藏
页数:4
相关论文
共 10 条
  • [1] In-depth point-spread-function characterization in multiphoton fluorescence microscopy
    Lee, YC
    Dong, CY
    So, P
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 494A - 494A
  • [2] Massively parallel image restoration with spatially variant point-spread-function
    Gorman, G
    Wilson, N
    Butler, R
    Shearer, A
    PDPTA'2001: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED PROCESSING TECHNIQUES AND APPLICATIONS, 2001, : 1073 - 1079
  • [3] Parallel image restoration with spatially variant point-spread-function - Description and first clinical results.
    Shearer, A
    Gorman, G
    O'Doherty, T
    van der Putten, W
    McCarthy, P
    Jelen, L
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 787 - 795
  • [4] Effect of pupil diameter on the retinal image quality calculated from double-pass point-spread-function measurements
    Borja, D
    Manns, F
    Takeuchi, G
    Shibutani, M
    Yoo, ES
    Lee, Y
    Culbertson, W
    Kobayashi, K
    Parel, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [5] Blind Image Restoration with Defocus Blur by Estimating Point Spread Function in Frequency Domain
    Qin, Fengqing
    Li, Chaorong
    Cao, Lilan
    Zhu, Lihong
    Zou, Xuyan
    Li, Xiaomei
    Zhang, Tianqi
    Xue, Yilan
    2021 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN IMAGE PROCESSING, ICAIP 2021, 2021, : 62 - 67
  • [6] RESTORATION OF SHIFT VARIANT BLURRED IMAGE ESTIMATING THE PARAMETER DISTRIBUTION OF POINT-SPREAD FUNCTION
    HASHIMOTO, S
    SAITO, H
    SYSTEMS AND COMPUTERS IN JAPAN, 1995, 26 (01) : 62 - 72
  • [7] IMAGE-RESTORATION USING THE POINT SPREAD FUNCTION OF THE HALLEY MULTICOLOR CAMERA
    KRAMM, JR
    MOHRING, W
    KELLER, HU
    GEOPHYSICAL RESEARCH LETTERS, 1987, 14 (07) : 677 - 680
  • [8] Point spread function estimation based on wavelet transform for image restoration - art. no. 68331M
    Chen Xiao-xuan
    Fan Zhi-gang
    ELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY V, PTS 1 AND 2, 2008, 6833 : M8331 - M8331
  • [9] Single-pinhole confocal imaging of sub-resolution sparse objects using experimental point spread function and image restoration
    Diaspro, A
    Annunziata, S
    Robello, M
    MICROSCOPY RESEARCH AND TECHNIQUE, 2000, 51 (05) : 464 - 468
  • [10] Image restoration for three-dimensional fluorescence microscopy using an orthonormal basis for efficient representation of depth-variant point-spread functions
    Patwary, Nurmohammed
    Preza, Chrysanthe
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (10): : 3826 - 3841