Dry Electrodes for Capturing Brain Electrical Signals

被引:1
|
作者
Ferreira, Luiz G. [1 ]
Pimenta, Tales C. [1 ]
机构
[1] Univ Fed Itajuba, Itajuba, Brazil
来源
2024 31ST INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEM, MIXDES 2024 | 2024年
关键词
Electroencephalogram; EEG; Dry-electrode; Wet-electrode;
D O I
10.23919/MIXDES62605.2024.10613935
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Almost a hundred years ago, in 1924, the first electroencephalogram - EEG, recording of brain electrical activity, was conducted by placing a metal electrode over the scalp with a conductive electrolytic gel. The electrode was connected to a signal amplifier and a signal recorder. Over the years, there has been great improvements in EEG equipments, including integrated circuits that can offer amplification, filtering and even the measurement of electrode contact impedance. However, only after the 1990s, new types of electrodes were considered to replace the traditional electrodes that requires gel, such as the dry electrodes. There are several models of dry electrodes, but they have not yet found a model that is fully accepted among clinicians. In this article we provide an overview of the current dry electrode technologies.
引用
收藏
页码:290 / 293
页数:4
相关论文
共 50 条
  • [31] Validation of Soft Multipin Dry EEG Electrodes
    Heijs, Janne J. A.
    Havelaar, Ruben Jan
    Fiedler, Patrique
    van Wezel, Richard J. A.
    Heida, Tjitske
    SENSORS, 2021, 21 (20)
  • [32] Dry contact electrodes performance in canine ECG
    Virtanen, Juhani
    Leivo, Joni
    Vehkaoja, Antti
    Somppi, Sanni
    Tornqvist, Heini
    Fiedler, Patrique
    Vaataja, Heli
    Surakka, Veikko
    FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018), 2018,
  • [33] Dry Electrodes for Human Bioelectrical Signal Monitoring
    Fu, Yulin
    Zhao, Jingjing
    Dong, Ying
    Wang, Xiaohao
    SENSORS, 2020, 20 (13) : 1 - 30
  • [34] Significant Frequency Range of Brain Wave Signals for Authentication
    Tangkraingkij, Preecha
    SOFTWARE ENGINEERING, ARTIFICIAL INTELLIGENCE, NETWORKING AND PARALLEL/DISTRIBUTED COMPUTING 2015, 2016, 612 : 103 - 113
  • [35] A Fast and Accurate SSVEP Brain Machine Interface Using Dry Electrodes and High Frequency Stimuli by Employing Ensemble Learning
    Silva, A.
    Cruz, G.
    Pinheiro, C.
    IEEE LATIN AMERICA TRANSACTIONS, 2020, 18 (06) : 1000 - 1007
  • [36] Hyperthermia, but not dehydration, alters the electrical activity of the brain
    van den Heuvel, Anne M. J.
    Haberley, Benjamin J.
    Hoyle, David J. R.
    Taylor, Nigel A. S.
    Croft, Rodney J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2020, 120 (12) : 2797 - 2811
  • [37] Use of brain electrical activity to quantify traumatic brain injury in the emergency department
    Naunheim, Rosanne S.
    Treaster, Matthew
    English, Joy
    Casner, Teya
    Chabot, Robert
    BRAIN INJURY, 2010, 24 (11) : 1324 - 1329
  • [38] Editorial: Dry Electroencephalography for Brain Monitoring in Sports and Movement Science
    Comani, Silvia
    Bertollo, Maurizio
    Haueisen, Jens
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [39] Multichannel EEG with novel Ti/TiN dry electrodes
    Fiedler, P.
    Griebel, S.
    Pedrosa, P.
    Fonseca, C.
    Vaz, F.
    Zentner, L.
    Zanow, F.
    Haueisen, J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 221 : 139 - 147
  • [40] THE STATUS OF TEXTILE-BASED DRY EEG ELECTRODES
    Tseghai, Granch Berhe
    Malengier, Benny
    Fante, Kinde Anlay
    Van Langenhove, Lieva
    AUTEX RESEARCH JOURNAL, 2021, 21 (01) : 63 - 70