Dry Electrodes for Capturing Brain Electrical Signals

被引:1
|
作者
Ferreira, Luiz G. [1 ]
Pimenta, Tales C. [1 ]
机构
[1] Univ Fed Itajuba, Itajuba, Brazil
来源
2024 31ST INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEM, MIXDES 2024 | 2024年
关键词
Electroencephalogram; EEG; Dry-electrode; Wet-electrode;
D O I
10.23919/MIXDES62605.2024.10613935
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Almost a hundred years ago, in 1924, the first electroencephalogram - EEG, recording of brain electrical activity, was conducted by placing a metal electrode over the scalp with a conductive electrolytic gel. The electrode was connected to a signal amplifier and a signal recorder. Over the years, there has been great improvements in EEG equipments, including integrated circuits that can offer amplification, filtering and even the measurement of electrode contact impedance. However, only after the 1990s, new types of electrodes were considered to replace the traditional electrodes that requires gel, such as the dry electrodes. There are several models of dry electrodes, but they have not yet found a model that is fully accepted among clinicians. In this article we provide an overview of the current dry electrode technologies.
引用
收藏
页码:290 / 293
页数:4
相关论文
共 50 条
  • [21] Capturing Human Perceptual and Cognitive Activities via Event-Related Potentials Measured with Candle-Like Dry Microneedle Electrodes
    Yoshida, Yuri
    Kawana, Takumi
    Hoshino, Eiichi
    Minagawa, Yasuyo
    Miki, Norihisa
    MICROMACHINES, 2020, 11 (06)
  • [22] Comparison of dry and gel based electrodes for P300 brain-computer interfaces
    Guger, Christoph
    Krausz, Gunther
    Allison, Brendan Z.
    Edlinger, Guenter
    FRONTIERS IN NEUROSCIENCE, 2012, 6
  • [23] A novel dry-contact electrode for measuring electroencephalography signals
    Liu, Juntao
    Liu, Xinyang
    He, Enhui
    Gao, Fei
    Li, Ziyue
    Xiao, Guihua
    Xu, Shengwei
    Cai, Xinxia
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 294 : 73 - 80
  • [24] A mobile EEG system with dry electrodes
    Gargiulo, Gaetano
    Bifulco, Paolo
    Calvo, Rafael A.
    Cesarelli, Mario
    Jin, Craig
    van Schaik, Andre
    2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS), 2008, : 273 - +
  • [25] Flower electrodes for comfortable dry electroencephalography
    Warsito, Indhika Fauzhan
    Komosar, Milana
    Bernhard, Maria Anne
    Fiedler, Patrique
    Haueisen, Jens
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [26] Novel dry electrodes for ECG monitoring
    Gruetzmann, Anna
    Hansen, Stefan
    Mueller, Joerg
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1375 - 1390
  • [27] A comparative study of electrical potential sensors and Ag/AgCl electrodes for characterising spontaneous and event related electroencephalagram signals
    Fatoorechi, M.
    Parkinson, J.
    Prance, R. J.
    Prance, H.
    Seth, A. K.
    Schwartzman, D. J.
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 251 : 7 - 16
  • [28] Boundary element fast multipole method for modeling electrical brain stimulation with voltage and current electrodes
    Makarov, Sergey N.
    Golestanirad, Laleh
    Wartman, William A.
    Nguyen, Bach Thanh
    Noetscher, Gregory M.
    Ahveninen, Jyrki P.
    Fujimoto, Kyoko
    Weise, Konstantin
    Nummenmaa, Aapo R.
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (04)
  • [29] Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting
    Li, Guangli
    Wang, Sizhe
    Duan, Yanwen Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 277 : 250 - 260
  • [30] Capturing Brain Activity During Driving Automobile
    Koudelkova, Zuzana
    Jasek, Roman
    13TH INTERNATIONAL SCIENTIFIC CONFERENCE ON SUSTAINABLE, MODERN AND SAFE TRANSPORT (TRANSCOM 2019), 2019, 40 : 1434 - 1440