Capillary zone electrophoresis-tandem mass spectrometry for in-depth proteomics analysis via data-independent acquisition

被引:0
|
作者
Liu, Rong [1 ,2 ,3 ]
Lu, Gang [4 ]
Hu, Xiaozhong [1 ,2 ,3 ]
Li, Junhui [1 ,2 ,3 ]
Zhang, Zhenbin [4 ]
Tang, Keqi [1 ,2 ,3 ]
机构
[1] Ningbo Univ, Inst Mass Spectrometry, Zhejiang Engn Res Ctr Adv Mass Spectrometry & Clin, Ningbo 315211, Peoples R China
[2] Zhenhai Inst Mass Spectrometry, Ningbo 315211, Peoples R China
[3] Ningbo Univ, Sch Mat Sci & Chem Engn, Ningbo 315211, Peoples R China
[4] Ningbo Univ, Inst Drug Discovery Technol, Ningbo 315211, Peoples R China
基金
中国国家自然科学基金;
关键词
Data-independent acquisition; Data-dependent acquisition; Capillary zone electrophoresis; Mass spectrometry; Biomarker protein; Bottom-up proteomics; ELECTROSPRAY-IONIZATION; PEPTIDE IDENTIFICATIONS;
D O I
10.1007/s00216-024-05502-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A capillary zone electrophoresis (CZE) system was coupled to an Orbitrap mass spectrometer operating in a data-independent acquisition (DIA) mode for in-depth proteomics analysis. The performance of this CZE-DIA-MS system was systemically evaluated and optimized under different operating conditions. The performance of the fully optimized CZE-DIA-MS system was subsequently compared to the one by using the same CZE-MS system operating in a data-dependent acquisition (DDA) mode. The experimental results show that the numbers of identified peptides and proteins acquired in the DIA mode are much higher than the ones acquired in the DDA mode, especially with the small sample loading amount. Specifically, the numbers of identified peptides and proteins acquired in the DIA mode are 1.8-fold and 2-fold higher than the ones acquired in the DDA mode by using 12.5 ng Hela digests. The proteins identified in the DIA mode also cover almost all the proteins identified in the DDA mode. In addition, a potential cancer biomarker protein, carbohydrate antigen 125, undetected in the DDA mode, can be easily identified in the DIA mode even with 12.5 ng Hela digests. The performance of the CZE-DIA-MS system for in-depth proteomics analysis with a limited sample amount has been fully demonstrated for the first time through this study.
引用
收藏
页码:5805 / 5814
页数:10
相关论文
共 50 条
  • [41] Untargeted, spectral library-free analysis of data-independent acquisition proteomics data generated using Orbitrap mass spectrometers
    Tsou, Chih-Chiang
    Tsai, Chia-Feng
    Teo, Guo Ci
    Chen, Yu-Ju
    Nesvizhskii, Alexey I.
    PROTEOMICS, 2016, 16 (15-16) : 2257 - 2271
  • [42] Determination of Mitragynine and 7-Hydroxymitragynine in Raw Kratom Plant Material by a Multisegment Injection Capillary Zone Electrophoresis-Tandem Mass Spectrometry
    Horniakova, Andrea
    Mikus, Peter
    Piestansky, Juraj
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (03)
  • [43] Analysis of intact venom proteins with capillary zone electrophoresis - mass spectrometry
    Vishwakarma, Gayatri
    Andrasi, Melinda
    Szabo, Ruben
    Hajdu, Peter
    Petrilla, Vladimir
    Petrillova, Monika
    Legath, Jaroslav
    Gaspar, Attila
    MICROCHEMICAL JOURNAL, 2024, 200
  • [44] Rapid and multi-level characterization of trastuzumab using sheathless capillary electrophoresis-tandem mass spectrometry
    Gahoual, Rabah
    Burr, Alicia
    Busnel, Jean-Marc
    Kuhn, Lauriane
    Hammann, Phillipe
    Beck, Alain
    Francois, Yannis-Nicolas
    Leize-Wagner, Emmanuelle
    MABS, 2013, 5 (03) : 479 - 490
  • [45] Evaluating the Performance of the Astral Mass Analyzer for Quantitative Proteomics Using Data-Independent Acquisition
    Heil, Lilian R.
    Damoc, Eugen
    Arrey, Tabiwang N.
    Pashkova, Anna
    Denisov, Eduard
    Petzoldt, Johannes
    Peterson, Amelia C.
    Hsu, Chris
    Searle, Brian C.
    Shulman, Nicholas
    Riffle, Michael
    Connolly, Brian
    Maclean, Brendan X.
    Remes, Philip M.
    Senko, Michael W.
    Stewart, Hamish I.
    Hock, Christian
    Makarov, Alexander A.
    Hermanson, Daniel
    Zabrouskov, Vlad
    Wu, Christine C.
    Maccoss, Michael J.
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (10) : 3290 - 3300
  • [46] In-depth evaluation of software tools for data-independent acquisition based label-free quantification
    Kuharev, Jorg
    Navarro, Pedro
    Distler, Ute
    Jahn, Olaf
    Tenzer, Stefan
    PROTEOMICS, 2015, 15 (18) : 3140 - 3151
  • [47] Selected product ion monitoring for quantification of 5-hydroxymethylfurfural in food products by capillary zone electrophoresis-tandem ion trap mass spectrometry
    Bignardi, Chiara
    Cavazza, Antonella
    Corradini, Claudio
    FOOD CONTROL, 2014, 46 : 41 - 48
  • [48] Single-Shot Capillary Zone Electrophoresis-Tandem Mass Spectrometry Produces over 4400 Phosphopeptide Identifications from a 220 ng Sample
    Zhang, Zhenbin
    Hebert, Alexander S.
    Westphall, Michael S.
    Coon, Joshua J.
    Dovichi, Norman J.
    JOURNAL OF PROTEOME RESEARCH, 2019, 18 (08) : 3166 - 3173
  • [49] metaExpertPro: A Computational Workflow for Metaproteomics Spectral Library Construction and Data-Independent Acquisition Mass Spectrometry Data Analysis
    Sun, Yingying
    Xing, Ziyuan
    Liang, Shuang
    Miao, Zelei
    Zhuo, Lai-bao
    Jiang, Wenhao
    Zhao, Hui
    Gao, Huanhuan
    Xie, Yuting
    Zhou, Yan
    Yue, Liang
    Cai, Xue
    Chen, Yu-ming
    Zheng, Ju-Sheng
    Guo, Tiannan
    MOLECULAR & CELLULAR PROTEOMICS, 2024, 23 (10)
  • [50] Analysis of 1508 Plasma Samples by Capillary-Flow Data-Independent Acquisition Profiles Proteomics of Weight Loss and Maintenance
    Bruderer, Roland
    Muntel, Jan
    Muller, Sebastian
    Bernhard, Oliver M.
    Gandhi, Tejas
    Cominetti, Ornella
    Macron, Charlotte
    Carayol, Jerome
    Rinner, Oliver
    Astrup, Arne
    Saris, Wim H. M.
    Hager, Jorg
    Valsesia, Armand
    Dayon, Loic
    Reiter, Lukas
    MOLECULAR & CELLULAR PROTEOMICS, 2019, 18 (06) : 1242 - 1254