Sound Localization in Active Transcutaneous Bone Conduction Implant Users with Single-Sided Deafness

被引:0
|
作者
Epperson, Madison V. [1 ]
Jones, Gerilyn [2 ]
Abdulrazzak, Obada [2 ]
Anidi, Chioma [3 ]
Ibrahim, Nadine [1 ]
Banakis Hartl, Renee [1 ]
机构
[1] Univ Michigan, Dept Otolaryngol Head & Neck Surg, 1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Kresge Hearing Res Inst, Dept Otolaryngol Head & Neck Surg, Ann Arbor, MI USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI USA
关键词
Bone conduction implants; Single-sided deafness; Sound localization; ANCHORED HEARING-AIDS; SPEECH; DEVICE; NOISE;
D O I
10.1097/MAO.0000000000004284
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Evaluate sound localization accuracy of subjects with single-sided deafness (SSD) with active transcutaneous bone conduction implants (atBCIs). Study Design: Prospective case-control study. Setting: Tertiary referral center. Patients: Ten SSD patients (with ATBCIS) and 10 controls. Interventions: Localization was assessed in a semianechoic chamber using a 24-speaker array. Stimuli included broadband noise (BBN) and narrowband noise (NBN). Perceived stimulus angle was recorded and compared with presented location. Statistical analyses were performed using ANOVA and Wilcoxon rank sum tests. Main Outcome Measures: The primary outcome measures were as follows: 1) mean angular error (MAE) error (degrees) and regression slope and 2) subjective benefit assessment (Speech Spatial Qualities questionnaire). Results: Subjects with SSD demonstrated worse localization by MAE and regression slope compared with controls for both broadband noise (p < 0.0001) and narrowband noise at 500 Hz and 1000 kHz (p < 0.0001). There was no statistically significant difference (p = 0.1090) in slope between all groups at 4000 Hz. There was no significant difference in slope or MAE aided compared with unaided. Localization ability varied widely within the SSD cohort, with some individuals showing some ability in the unaided condition, best at 4000 Hz. Although SSQ confirmed particular difficulty in the spatial hearing domain, all domains improved with device use. Conclusions: Localization ability for individuals with SSD falls into a somewhat bimodal distribution. Some have fair localization, particularly at high frequencies, that is preserved but not improved with the atBCI. Others have minimal to no localization ability at any frequency, with no apparent device benefit.
引用
收藏
页码:855 / 862
页数:8
相关论文
共 50 条
  • [21] Improved interaural timing of acoustic nerve stimulation affects sound localization in single-sided deaf cochlear implant users
    Seebacher, J.
    Franke-Trieger, A.
    Weichbold, V
    Zorowka, R.
    Stephan, K.
    HEARING RESEARCH, 2019, 371 : 19 - 27
  • [22] Sound Localization in Single-Sided Deaf Participants Provided With a Cochlear Implant
    Ludwig, Alexandra Annemarie
    Meuret, Sylvia
    Battmer, Rolf-Dieter
    Schoenwiesner, Marc
    Fuchs, Michael
    Ernst, Arne
    FRONTIERS IN PSYCHOLOGY, 2021, 12
  • [23] Efficacy and Safety of an In-the-Mouth Bone Conduction Device for Single-Sided Deafness
    Murray, Michael
    Popelka, Gerald R.
    Miller, Ross
    OTOLOGY & NEUROTOLOGY, 2011, 32 (03) : 437 - 443
  • [24] Long-Term Benefit and Sound Localization in Patients With Single-Sided Deafness Rehabilitated With an Osseointegrated Bone-Conduction Device
    Nicolas, Saroul
    Mohamed, Akkari
    Yoann, Pavier
    Laurent, Gilain
    Thierry, Mom
    OTOLOGY & NEUROTOLOGY, 2013, 34 (01) : 111 - 114
  • [25] Effect of Tinnitus and Duration of Deafness on Sound Localization and Speech Recognition in Noise in Patients With Single-Sided Deafness
    Liu, Yang-Wenyi
    Cheng, Xiaoting
    Chen, Bing
    Peng, Kevin
    Ishiyama, Akira
    Fu, Qian-Jie
    TRENDS IN HEARING, 2018, 22
  • [26] A New Active Osseointegrated Implant System in Patients with Single-Sided Deafness
    Willenborg, Kerstin
    Avallone, Emilio
    Maier, Hannes
    Lenarz, Thomas
    Busch, Susan
    AUDIOLOGY AND NEURO-OTOLOGY, 2022, 27 (01) : 83 - 91
  • [27] Speech Quality Perception in Unilateral Cochlear Implant Users With Single-Sided Deafness
    Kelly, Scott
    Kuhlmey, Megan E.
    Despotidis, Meghan A.
    Alter, Isaac L.
    Hwa, Tiffany P.
    Chern, Alexander
    Lalwani, Anil K.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2025, 172 (01) : 224 - 232
  • [28] Sound Localization in Patients With Congenital Unilateral Conductive Hearing Loss With a Transcutaneous Bone Conduction Implant
    Vyskocil, Erich
    Liepins, Rudolfs
    Kaider, Alexandra
    Blineder, Michaela
    Hamzavi, Sasan
    OTOLOGY & NEUROTOLOGY, 2017, 38 (03) : 318 - 324
  • [29] Speech Perception in Noise and Sound Localization for Cochlear Implant With Single-Sided Deafness Compared With Contralateral Routing of Signal Hearing Aids
    Oyamada, Shogo
    Takahashi, Masahiro
    Furutate, Sakiko
    Oka, Shinichirou
    Kubota, Eri
    Sakurai, Azusa
    Uekusa, Tomoko
    Watanabe, Kana
    Iwasaki, Satoshi
    OTOLOGY & NEUROTOLOGY, 2023, 44 (04) : 331 - 338
  • [30] The impact of cochlear implant microphone settings on the binaural hearing of experienced cochlear implant users with single-sided deafness
    Kurz, Anja
    Zanzinger, Maren
    Hagen, Rudolf
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (06) : 2067 - 2077