Sound Localization in Active Transcutaneous Bone Conduction Implant Users with Single-Sided Deafness

被引:0
|
作者
Epperson, Madison V. [1 ]
Jones, Gerilyn [2 ]
Abdulrazzak, Obada [2 ]
Anidi, Chioma [3 ]
Ibrahim, Nadine [1 ]
Banakis Hartl, Renee [1 ]
机构
[1] Univ Michigan, Dept Otolaryngol Head & Neck Surg, 1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Kresge Hearing Res Inst, Dept Otolaryngol Head & Neck Surg, Ann Arbor, MI USA
[3] Univ Michigan, Sch Med, Ann Arbor, MI USA
关键词
Bone conduction implants; Single-sided deafness; Sound localization; ANCHORED HEARING-AIDS; SPEECH; DEVICE; NOISE;
D O I
10.1097/MAO.0000000000004284
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Evaluate sound localization accuracy of subjects with single-sided deafness (SSD) with active transcutaneous bone conduction implants (atBCIs). Study Design: Prospective case-control study. Setting: Tertiary referral center. Patients: Ten SSD patients (with ATBCIS) and 10 controls. Interventions: Localization was assessed in a semianechoic chamber using a 24-speaker array. Stimuli included broadband noise (BBN) and narrowband noise (NBN). Perceived stimulus angle was recorded and compared with presented location. Statistical analyses were performed using ANOVA and Wilcoxon rank sum tests. Main Outcome Measures: The primary outcome measures were as follows: 1) mean angular error (MAE) error (degrees) and regression slope and 2) subjective benefit assessment (Speech Spatial Qualities questionnaire). Results: Subjects with SSD demonstrated worse localization by MAE and regression slope compared with controls for both broadband noise (p < 0.0001) and narrowband noise at 500 Hz and 1000 kHz (p < 0.0001). There was no statistically significant difference (p = 0.1090) in slope between all groups at 4000 Hz. There was no significant difference in slope or MAE aided compared with unaided. Localization ability varied widely within the SSD cohort, with some individuals showing some ability in the unaided condition, best at 4000 Hz. Although SSQ confirmed particular difficulty in the spatial hearing domain, all domains improved with device use. Conclusions: Localization ability for individuals with SSD falls into a somewhat bimodal distribution. Some have fair localization, particularly at high frequencies, that is preserved but not improved with the atBCI. Others have minimal to no localization ability at any frequency, with no apparent device benefit.
引用
收藏
页码:855 / 862
页数:8
相关论文
共 50 条
  • [1] Multicenter Results With an Active Transcutaneous Bone Conduction Implant in Patients With Single-sided Deafness
    Huber, Alexander M.
    Strauchmann, Bernd
    Caversaccio, Marco D.
    Wimmer, Wilhelm
    Linder, Thomas
    De Min, Nicola
    Hempel, John-Martin
    Pollotzek, Marlene
    Frenzel, Henning
    Hanke, Frauke
    Roeoesli, Christof
    OTOLOGY & NEUROTOLOGY, 2022, 43 (02) : 227 - 235
  • [2] Impact of Reverberation on Speech Perception and Sound Localization Accuracy in Cochlear Implant Users With Single-Sided Deafness
    Koertje, Monika
    Eichenauer, Anja
    Stoever, Timo
    Baumann, Uwe
    Weissgerber, Tobias
    OTOLOGY & NEUROTOLOGY, 2022, 43 (01) : E30 - E37
  • [3] Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
    Zhang, Xiao
    Bai, Jie
    Lin, Zhihan
    Li, Ying
    Liu, Haihong
    Yang, Yang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (214):
  • [4] Review: Bone Conduction Devices and Contralateral Routing of Sound Systems in Single-Sided Deafness
    Peters, Jeroen P. M.
    Smit, Adriana L.
    Stegeman, Inge
    Grolman, Wilko
    LARYNGOSCOPE, 2015, 125 (01) : 218 - 226
  • [5] Transcutaneous Bone Conduction Implants in Patients With Single-Sided Deafness: Objective and Subjective Evaluation
    AlFarraj, Ali
    AlIbrahim, Manal
    AlHajjaj, Haifa
    Khater, Fatima
    AlGhamdi, Ali
    Fayad, Jose
    ENT-EAR NOSE & THROAT JOURNAL, 2022, : NP92 - NP100
  • [6] Long-Term Improvement in Localization for Cochlear Implant Users with Single-Sided Deafness
    Thompson, Nicholas J.
    Dillon, Margaret T.
    Buss, Emily
    Rooth, Meredith A.
    Richter, Margaret E.
    Pillsbury, Harold C.
    Brown, Kevin D.
    LARYNGOSCOPE, 2022, 132 (12) : 2453 - 2458
  • [7] Functional Results and Subjective Benefit of a Transcutaneous Bone Conduction Device in Patients With Single-Sided Deafness
    Laske, Roman D.
    Roeoesli, Christof
    Pfiffner, Flurin
    Veraguth, Dorothe
    Huber, Alex M.
    OTOLOGY & NEUROTOLOGY, 2015, 36 (07) : 1151 - 1156
  • [8] The Sound of a Cochlear Implant Investigated in Patients With Single-Sided Deafness and a Cochlear Implant
    Peters, Jeroen P. M.
    Wendrich, Anne W.
    van Eijl, Ruben H. M.
    Rhebergen, Koenraad S.
    Versnel, Huib
    Grolman, Wilko
    OTOLOGY & NEUROTOLOGY, 2018, 39 (06) : 707 - 714
  • [9] Sound localisation of low- and high-frequency sounds in cochlear implant users with single-sided deafness
    Seebacher, J.
    Franke-Trieger, A.
    Weichbold, V
    Galvan, O.
    Schmutzhard, J.
    Zorowka, P.
    Stephan, K.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2023, 62 (01) : 71 - 78
  • [10] Speech Perception Outcomes in Transcutaneous Versus Percutaneous Bone Conduction Stimulation in Individuals With Single-sided Deafness
    Snapp, Hillary A.
    Morgenstein, Kari E.
    Kuzbyt, Brianna
    OTOLOGY & NEUROTOLOGY, 2019, 40 (08) : 1068 - 1075