Monte Carlo simulation and optimization of neutron ray shielding performance of related materials

被引:2
|
作者
Cui, Tongyan [1 ]
Wang, Faquan [1 ]
Bing, Linhan [1 ]
Wang, Rui [1 ]
Ma, Zhongjian [2 ]
Jia, Qingxiu [1 ]
机构
[1] Beijing Inst Fash Technol, Sch Mat Design & Engn, Beijing 100029, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
关键词
Monte Carlo simulation; Rare earth; Polymers; Neutron rays; NITRIDE COMPOSITES; CONCRETE;
D O I
10.1016/j.net.2024.04.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Polymers have become widely used substrate materials for shielding neutron rays because of their high hydrogen content and easy processing procedures. Rare-earth materials are also being gradually adopted as neutron absorbers because of their considerable thermal neutron absorption cross-sections. This paper utilizes the FLUKA Monte Carlo simulation program to compare the shielding effects of various polymers and rare-earth oxides on neutron rays across different energy ranges. The study investigates the superior shielding materials for neutron radiation in each energy range. Subsequently, a series of materials are simulated by combining the preferred shielding materials for neutron rays in each energy range, exploring the influence of material composition and composite structure on the effectiveness of neutron ray shielding. It is revealed that the preferred material for shielding neutron rays changes for different energy ranges. For low-energy neutron rays, rare-earth oxides such as Sm2O3 and Gd2O3 demonstrate the most effective shielding, whereas for high-energy neutron rays, polyethylene (PE) provides the best shielding performance. Materials with different compositions show varying preferred structures when dealing with a Cf-252 neutron source. However, in mitigating the secondary gamma rays generated during the neutron shielding process, stacked-type materials exhibit the most effective shielding performance.
引用
收藏
页码:3545 / 3552
页数:8
相关论文
共 50 条
  • [31] Improved shielding design with an accelerated Monte Carlo simulation for a neutron generator at Missouri S&T
    Sahiner, Huseyin
    Norris, Edward T.
    Bugis, Abdulaleem A.
    Liu, Xin
    PROGRESS IN NUCLEAR ENERGY, 2017, 97 : 123 - 132
  • [32] Introduction of Graphene/h-BN Metamaterial as Neutron Radiation Shielding by Implementing Monte Carlo Simulation
    Hassanpour, Marzieh
    Hassanpour, Mehdi
    Faghihi, Simin
    Khezripour, Saeedeh
    Rezaie, Mohammadreza
    Dehghanipour, Parvin
    Faruque, Mohammad Rashed Iqbal
    Khandaker, Mayeen Uddin
    MATERIALS, 2022, 15 (19)
  • [33] Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault
    Zheng, Yuanshui
    Newhauser, Wayne
    Klein, Eric
    Low, Daniel
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6943 - 6957
  • [34] A PRELIMINARY STUDY ON PHOTONEUTRON SHIELDING OPTIMIZATION IN A MEDICAL ACCELERATOR ROOM BY USING MONTE CARLO SIMULATION
    Kim, Y. N.
    Jeong, K.
    Lee, C. G.
    Lee, I. J.
    Seong, J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S424 - S425
  • [35] MONTE CARLO SIMULATION OF ACTIVE NEUTRON INTERROGATION SYSTEM DEVELOPED FOR DETECTION OF ILLICIT MATERIALS
    Georgadze, A. Sh.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1683 - 1691
  • [36] Monte Carlo simulation of a high-efficacy composite material: feasibility for neutron and gamma ray shielding of Small Modular Reactor (SMR) facilities
    Mukherjee, B.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [37] Monte Carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    Burkovskii, R. G.
    Vakhrushev, S. B.
    Zvorykina, O. I.
    Naberezhnov, A. A.
    Okuneva, N. M.
    Filimonov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2007, 52 (03) : 552 - 557
  • [38] Monte carlo simulation and optimization of three-axis neutron spectrometer for the PIK reactor
    R. G. Burkovskiĭ
    S. B. Vakhrushev
    O. I. Zvorykina
    A. A. Naberezhnov
    N. M. Okuneva
    A. V. Filimonov
    Crystallography Reports, 2007, 52 : 552 - 557
  • [39] Optimization of filler content and minimizing thickness of polymeric composite for shielding against neutron source by Response Surface Methodology (RSM) and Monte Carlo simulation
    Ghasem Rahimi
    Dumitru Chirlesan
    Zahra Soltani
    The European Physical Journal Special Topics, 2023, 232 : 1657 - 1663
  • [40] Radiation shielding design for neutron diffractometers assisted by Monte Carlo methods
    Osborn, John C.
    Ersez, Tunay
    Braoudakis, George
    PHYSICA B-CONDENSED MATTER, 2006, 385-86 : 1321 - 1323