Efficacy and Safety of Different Hybrid Closed Loop Systems for Automated Insulin Delivery in People With Type 1 Diabetes: A Systematic Review and Network Meta-Analysis

被引:3
|
作者
Di Molfetta, Sergio [1 ]
Di Gioia, Ludovico [1 ]
Caruso, Irene [1 ]
Cignarelli, Angelo [1 ]
Green, Suetonia C. [2 ]
Natale, Patrizia [3 ,4 ,5 ]
Strippoli, Giovanni F. M. [3 ,4 ]
Sorice, Gian Pio [1 ]
Perrini, Sebastio [1 ]
Natalicchio, Annalisa [1 ]
Laviola, Luigi [1 ]
Giorgino, Francesco [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Sect Internal Med Endocrinol Androl & Metab Dis, Bari, Italy
[2] Univ Otago Christchurch, Dept Med, Christchurch, New Zealand
[3] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Bari, Italy
[4] Univ Sydney, Sydney Sch Publ Hlth, Sydney, Australia
[5] Univ Foggia, Dept Med & Surg Sci, Nephrol Dialysis & Transplantat Unit, Foggia, Italy
关键词
automated insulin delivery; hybrid closed loop; Time In Range; type; 1; diabetes; GLYCEMIC CONTROL; CONSISTENCY; METRICS; LIFE;
D O I
10.1002/dmrr.3842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. Methods: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. Results: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD - 3.69%, 95% CI [-5.2; - 5.2; - 2.19], high certainty), Minimed 670G (MD - 2.9%, 95% CI [-3.77; - 3.77; - 2.04], moderate certainty) and Minimed 780G (MD - 2.79%, 95% CI [-3.94; - 3.94; - 1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. Conclusions: We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Automated insulin delivery in children with type 1 diabetes during physical activity: a meta-analysis
    Wang, Yuan-yuan
    Ying, Hui-min
    Tian, Fang
    Qian, Xiao-lu
    Zhou, Zhen-feng
    Zhou, Chun-cong
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2024, 37 (06): : 505 - 515
  • [42] Efficacy of theory-based interventions for young people with type 1 diabetes: A systematic review and meta-analysis
    Ayling, Kieran
    Brierley, Samantha
    Johnson, Barbara
    Heller, Simon
    Eiser, Christine
    BRITISH JOURNAL OF HEALTH PSYCHOLOGY, 2015, 20 (02) : 428 - 446
  • [43] Closed-Loop Insulin Delivery Systems for People with Type 1 Diabetes and Chronic Very Poor Metabolic Control: It Works and Is Safe!
    Deepchand, Sonia
    Balla, Vanessa
    Eroukhmanoff, Juliette
    Sall, Khadijatou Ly
    Romain, Benedicte
    Lejeune, Marie
    Penfornis, Alfred
    Amadou, Coralie
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (02) : 125 - 129
  • [44] Comparative efficacy and safety of glucose-lowering drugs in children and adolescents with type 2 diabetes: A systematic review and network meta-analysis
    Wu, Sijia
    He, Yina
    Wu, Yutong
    Ji, Yiman
    Hou, Lei
    Liu, Xinhui
    Ge, Yilei
    Yu, Yuanyuan
    Yu, Yifan
    Wei, Yun
    Qian, Fengtong
    Luo, Qingxin
    Feng, Yue
    Feng, Yiping
    Wang, Jiongjiong
    Huo, Meiling
    Li, Hongkai
    Xue, Fuzhong
    Liu, Yunxia
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [45] The efficacy and safety of DPP4 inhibitors in patients with type 1 diabetes: A systematic review and meta-analysis
    Guo, Heming
    Fang, Chen
    Huang, Yun
    Pei, Yufang
    Chen, Linqi
    Hu, Ji
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 121 : 184 - 191
  • [46] Efficacy and safety of the addition of a dipeptidyl peptidase-4 inhibitor to insulin therapy in patients with type 2 diabetes: A systematic review and meta-analysis
    Kim, Yeong Gi
    Min, Se Hee
    Hahn, Seokyung
    Oh, Tae Jung
    Park, Kyong Soo
    Cho, Young Min
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 116 : 86 - 95
  • [47] Efficacy of advanced hybrid closed loop systems for the management of type 1 diabetes in children
    Ferrito, Lucia
    Passanisi, Stefano
    Bonfanti, Riccardo
    Cherubini, Valentino
    Minuto, Nicola
    Schiaffini, Riccardo
    Scaramuzza, Andrea
    MINERVA PEDIATRICS, 2021, 73 (06): : 474 - 485
  • [48] Exercise modalities for type 2 diabetes: A systematic review and network meta-analysis of randomized trials
    Hou, Liangying
    Wang, Qi
    Pan, Bei
    Li, Rui
    Li, Yanfei
    He, Juanjuan
    Qin, Tianzhu
    Cao, Liujiao
    Zhang, Na
    Cao, Changhao
    Ge, Long
    Yang, Kehu
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2023, 39 (01)
  • [49] Hybrid Closed-Loop Versus Manual Insulin Delivery in Adults With Type 1 Diabetes: A Post Hoc Analysis Using the Glycemia Risk Index
    Lee, Melissa H.
    Vogrin, Sara
    Jones, Timothy W.
    O'Neal, David N.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 761 - +
  • [50] Efficacy and safety of metformin and sodium-glucose co-transporter-2 inhibitors in adults with type 1 diabetes: A systematic review and network meta-analysis
    Zhang, Q.
    Wu, Y.
    Lu, Y.
    Fei, X.
    REVISTA CLINICA ESPANOLA, 2020, 220 (01): : 8 - 21