Efficacy and Safety of Different Hybrid Closed Loop Systems for Automated Insulin Delivery in People With Type 1 Diabetes: A Systematic Review and Network Meta-Analysis

被引:3
|
作者
Di Molfetta, Sergio [1 ]
Di Gioia, Ludovico [1 ]
Caruso, Irene [1 ]
Cignarelli, Angelo [1 ]
Green, Suetonia C. [2 ]
Natale, Patrizia [3 ,4 ,5 ]
Strippoli, Giovanni F. M. [3 ,4 ]
Sorice, Gian Pio [1 ]
Perrini, Sebastio [1 ]
Natalicchio, Annalisa [1 ]
Laviola, Luigi [1 ]
Giorgino, Francesco [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Sect Internal Med Endocrinol Androl & Metab Dis, Bari, Italy
[2] Univ Otago Christchurch, Dept Med, Christchurch, New Zealand
[3] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Bari, Italy
[4] Univ Sydney, Sydney Sch Publ Hlth, Sydney, Australia
[5] Univ Foggia, Dept Med & Surg Sci, Nephrol Dialysis & Transplantat Unit, Foggia, Italy
关键词
automated insulin delivery; hybrid closed loop; Time In Range; type; 1; diabetes; GLYCEMIC CONTROL; CONSISTENCY; METRICS; LIFE;
D O I
10.1002/dmrr.3842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. Methods: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. Results: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD - 3.69%, 95% CI [-5.2; - 5.2; - 2.19], high certainty), Minimed 670G (MD - 2.9%, 95% CI [-3.77; - 3.77; - 2.04], moderate certainty) and Minimed 780G (MD - 2.79%, 95% CI [-3.94; - 3.94; - 1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. Conclusions: We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Efficacy and safety of empagliflozin for type 2 diabetes: a systematic review and meta-analysis
    Liakos, A.
    Karagiannis, T.
    Athanasiadou, E.
    Sarigianni, M.
    Mainou, M.
    Papatheodorou, K.
    Bekiari, E.
    Tsapas, A.
    DIABETES OBESITY & METABOLISM, 2014, 16 (10): : 984 - 993
  • [22] Efficacy and safety of carbohydrate restriction in patients with type 1 diabetes: A systematic review and meta-analysis
    Stamati, Athina
    Sotiriou, Georgia
    Karagiannis, Thomas
    Christoforidis, Athanasios
    DIABETES OBESITY & METABOLISM, 2023, 25 (09): : 2770 - 2773
  • [23] Efficacy of acceptance and commitment therapy for people with type 2 diabetes: Systematic review and meta-analysis
    Sakamoto, Ryo
    Ohtake, Yoichi
    Kataoka, Yuki
    Matsuda, Yoshinobu
    Hata, Tomokazu
    Otonari, Jun
    Yamane, Akira
    Matsuoka, Hiromichi
    Yoshiuchi, Kazuhiro
    JOURNAL OF DIABETES INVESTIGATION, 2022, 13 (02) : 262 - 270
  • [24] Comparative efficacy and safety of probiotics, prebiotics, and synbiotics for type 2 diabetes management: A systematic review and network meta-analysis
    Jayedi, Ahmad
    Aletaha, Azadeh
    Zeraattalab-Motlagh, Sheida
    Shahinfar, Hossein
    Mohammadpour, Saba
    Mirrafiei, Amin
    Jibril, Aliyu Tijani
    Soltani, Akbar
    Shab-Bidar, Sakineh
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2024, 18 (01)
  • [25] Efficacy of automated insulin delivery in pregnant women with type 1 diabetes: a meta-analysis and trial sequential analysis of randomized controlled trials
    Teixeira, Tamara
    Godoi, Amanda
    Romeiro, Pedro
    Novaes, Joao Vitor Levindo Coelho
    Faria, Flavia Maria de Freitas
    Pereira, Sacha
    Lamounier, Rodrigo Nunes
    ACTA DIABETOLOGICA, 2024, 61 (07) : 831 - 840
  • [26] Efficacy and Safety of Bromocriptine-QR in Type 2 Diabetes: A Systematic Review and Meta-Analysis
    Liang, W.
    Gao, L.
    Li, N.
    Wang, B.
    Wang, L.
    Wang, Y.
    Yang, H.
    You, L.
    Hou, J.
    Chen, S.
    Zhu, H.
    Jiang, Y.
    Pan, H.
    HORMONE AND METABOLIC RESEARCH, 2015, 47 (11) : 805 - 812
  • [27] Safety and Efficacy of Remogliflozin in People With Type 2 Diabetes Mellitus: A Systematic Review and Meta-Analysis
    Tewari, Jay
    Qidwai, Khalid Ahmad
    Rana, Anadika
    Tewari, Ajoy
    Tewari, Vineeta
    Maheshwari, Anuj
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [28] Review of a commercially available hybrid closed-loop insulin-delivery system in the treatment of Type 1 diabetes
    Stone, Jenine Y.
    Haviland, Nalani
    Bailey, Timothy S.
    THERAPEUTIC DELIVERY, 2018, 9 (02) : 77 - 87
  • [29] Efficacy and Safety of Once-Weekly Insulin Regimes on Glycemic Control for Type 2 Diabetes: A Systematic Review and Network Meta-analysis
    Wang, Peng
    Zhang, Yu
    Xu, Wenhao
    He, Jialing
    Peng, Liyuan
    Feng, Yuning
    Xu, Ping
    Chong, Weelic
    Hai, Yang
    Jia, Lu
    Fang, Fang
    DIABETOLOGY & METABOLIC SYNDROME, 2024, 16 (01):
  • [30] Real-world glycaemic outcomes of automated insulin delivery in type 1 diabetes: A meta-analysis
    Yang, Qin
    Zeng, Baoqi
    Hao, Jiayi
    Yang, Qingqing
    Sun, Feng
    DIABETES OBESITY & METABOLISM, 2024, 26 (09): : 3753 - 3763