Computational biomechanical study on hybrid implant materials for the femoral component of total knee replacements

被引:1
|
作者
Sass, Jan-Oliver [1 ]
Kebbach, Maeruan [1 ]
Lork, Cornelia [2 ]
Johannsen, Jan [3 ]
Weinmann, Markus [4 ]
Stenzel, Melanie [4 ]
Bader, Rainer [1 ]
机构
[1] Rostock Univ, Med Ctr, Dept Orthoped, Res Lab Biomech & Implant Technol, Doberaner Str 142, D-18057 Rostock, Germany
[2] ZM Praezisionsdentaltech GmbH, Breite Str 16, D-18055 Rostock, Germany
[3] Fraunhofer Res Inst Addit Mfg Technol IAPT, Schleusengraben 14, D-21029 Hamburg, Germany
[4] TANIOBIS GmbH, Schleeke 87-91, D-38642 Goslar, Germany
关键词
Total knee replacement; Femoral component; Implant material; Beta titanium; Alumina-toughened zirconia ceramic; Uncemented fixation; Bone-implant interaction; Stress shielding; Finite element analysis; MECHANICAL-PROPERTIES; BONE-DENSITY; TITANIUM IMPLANT; ARTHROPLASTY; FRACTURE; ALLOY; BIOCOMPATIBILITY; PERFORMANCE; STRENGTH; ADHESION;
D O I
10.1016/j.jmbbm.2024.106681
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multifunctional materials have been described to meet the diverse requirements of implant materials for femoral components of uncemented total knee replacements. These materials aim to combine the high wear and corrosion resistance of oxide ceramics at the joint surfaces with the osteogenic potential of titanium alloys at the bone-implant interface. Our objective was to evaluate the biomechanical performance of hybrid material-based femoral components regarding mechanical stress within the implant during cementless implantation and stress shielding (evaluated by strain energy density) of the periprosthetic bone during two-legged squat motion using finite element modeling. The hybrid materials consisted of alumina-toughened zirconia (ATZ) ceramic joined with additively manufactured Ti-6Al-4V or Ti-35Nb-6Ta alloys. The titanium component was modeled with or without an open porous surface structure. Monolithic femoral components of ATZ ceramic or Co-28Cr-6Mo alloy were used as reference. The elasticity of the open porous surface structure was determined within experimental compression tests and was significantly higher for Ti-35Nb-6Ta compared to Ti-6Al-4V (5.2 +/- 0.2 GPa vs. 8.8 +/- 0.8 GPa, p < 0.001). During implantation, the maximum stress within the ATZ femoral component decreased from 1568.9 MPa (monolithic ATZ) to 367.6 MPa (Ti-6Al-4V/ATZ), 560.9 MPa (Ti-6Al-4V/ATZ with an open porous surface), 474.9 MPa (Ti-35Nb-6Ta/ATZ), and 648.4 MPa (Ti-35Nb-6Ta/ATZ with an open porous surface). The strain energy density increased at higher flexion angles for all models during the squat movement. At similar to 90 degrees knee flexion, the strain energy density in the anterior region of the distal femur increased by 25.7 % (Ti-6Al-4V/ATZ), 70.3 % (Ti-6Al-4V/ATZ with an open porous surface), 43.7 % (Ti-35Nb-6Ta/ATZ), and 82.5% (Ti-35Nb-6Ta/ATZ with an open porous surface) compared to monolithic ATZ. Thus, the hybrid material-based femoral component decreases the intraoperative fracture risk of the ATZ part and considerably reduces the risk of stress shielding of the periprosthetic bone.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Precision CNC Machining of Femoral Component of Knee Implant: A Case Study
    Markopoulos, Angelos P.
    Galanis, Nikolaos I.
    Karkalos, Nikolaos E.
    Manolakos, Dimitrios E.
    MACHINES, 2018, 6 (01)
  • [2] The Effects of Different Femoral Component Materials on Bone and Implant Response in Total Knee Arthroplasty: A Finite Element Analysis
    Galas, Allegra
    Banci, Lorenzo
    Innocenti, Bernardo
    MATERIALS, 2023, 16 (16)
  • [3] Proximal tibial strain in medial unicompartmental knee replacements A BIOMECHANICAL STUDY OF IMPLANT DESIGN
    Scott, C. E. H.
    Eaton, M. J.
    Nutton, R. W.
    Wade, F. A.
    Pankaj, P.
    Evans, S. L.
    BONE & JOINT JOURNAL, 2013, 95B (10): : 1339 - 1347
  • [4] Comparison of Kinematics and Contact Mechanics in Normal Knee and Total Knee Replacements: A Computational Investigation
    Shu, Liming
    Sato, Takashi
    Hua, Xijin
    Sugita, Naohiko
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (09) : 2491 - 2502
  • [5] BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS
    Harman, Melinda K.
    Banks, Scott A.
    Fregly, Benjamin J.
    Sawyer, W. Gregory
    Hodge, W. Andrew
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2005, 5 (03) : 469 - 475
  • [6] Design and Simulation of a Femoral Component Peg in Total Knee Replacement
    Wang, Chang J.
    Shi, Jun F.
    Morgan, Colin
    Mynors, Diane J.
    ADVANCED DESIGN AND MANUFACTURE III, 2011, 450 : 111 - 114
  • [7] Computational Parametric Studies for Preclinical Evaluation of Total Knee Replacements
    Mell, Steven P.
    Fullam, Spencer
    Wimmer, Markus A.
    Lundberg, Hannah J.
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 36 : 60 - 85
  • [8] Topographical analysis of the femoral components of ex vivo total knee replacements
    Scholes, Susan C.
    Kennard, Emma
    Gangadharan, Rajkumar
    Weir, David
    Holland, Jim
    Deehan, David
    Joyce, Thomas J.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2013, 24 (02) : 547 - 554
  • [9] Topographical analysis of the femoral components of ex vivo total knee replacements
    Susan C. Scholes
    Emma Kennard
    Rajkumar Gangadharan
    David Weir
    Jim Holland
    David Deehan
    Thomas J. Joyce
    Journal of Materials Science: Materials in Medicine, 2013, 24 : 547 - 554
  • [10] Comparison of Kinematics and Contact Mechanics in Normal Knee and Total Knee Replacements: A Computational Investigation
    Liming Shu
    Takashi Sato
    Xijin Hua
    Naohiko Sugita
    Annals of Biomedical Engineering, 2021, 49 : 2491 - 2502