Comparison of Monte Carlo tally techniques for dosimetry in a transmission-type x-ray tube

被引:0
作者
Feng, Chen-Ju [1 ,2 ]
Lin, Chin-Hsiung [1 ,2 ,3 ]
Wu, Shu-Wei [4 ,5 ]
Luo, Shih-Yong [1 ,2 ]
Yang, Ya-Ru [1 ,2 ]
Lee, Chao-Hua [1 ,2 ]
Tseng, Shao-Chun [6 ]
Lee, Shen-Hao [4 ,7 ]
Hsu, Shih-Ming [1 ,2 ,7 ]
Wu, Chin-Hui [8 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Med Phys & Radiat Measurements Lab, Taipei, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[3] Koo Fdn Sun Yat Sen Canc Ctr, Dept Med Phys, Taipei, Taiwan
[4] Chang Gung Mem Hosp, Dept Radiat Oncol, Taoyuan, Taiwan
[5] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[6] NanoRay Biotech Co Ltd, Taipei, Taiwan
[7] Chinese Soc Med Phys, Taipei, Taiwan
[8] Tzu Chi Univ, Dept Med Imaging & Radiol Sci, Hualien, Taiwan
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2024年 / 10卷 / 06期
关键词
transmission x-ray tube; Monte Carlo simulation; figure of merit; dose conversion; SPECTRA;
D O I
10.1088/2057-1976/ad7bbf
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study discussed comparing result accuracy and time cost under different tally methods using MCNP6 for a novel transmission x-ray tube which was designed for the Auger electron yield with specific material (e.g. iodine). The assessment included photon spectrum, percent depth dose, mass-energy absorption coefficient corresponding to air and water, and figure of merit comparison. The mean energy of in-air phantom was from 41.8 keV (0 mm) to 40.9 keV (100 mm), and the mean energy of in-water phantom was from 41.41 keV (0 mm) to 45.2 keV (100 mm). The specific dose conversion factors based mass-energy absorption coefficient corresponding to different materials was established and the difference was less than 2% for the dose conversion of FMESH comparing to measurement data. FMESH had better figure of merit (FOM) than the F6 tally for the dose parameter assessment, which mean the dose calculation that focused on the superficial region could be assessed with more calculation efficiency by FMESH tally for this novel transmission x-ray tube. The results of this study could help develop treatment planning system (TPS) to quickly obtain the calculated data for phase space data establishment and heterogeneous correction under different physical condition settings.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Aghdam MRH, 2017, J RADIOTHER PRACT, V16, P29, DOI 10.1017/S1460396916000455
  • [2] 3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)
    Alhamada, Husein
    Simon, Stephane
    Philippson, Catherine
    Vandekerkhove, Christophe
    Jourani, Younes
    Pauly, Nicolas
    VanGestel, Dirk
    Reynaert, Nick
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 207 - 214
  • [3] Efficacy of various nanoparticle types in dose enhancement during low energy X-ray IORT: A Monte Carlo simulation study
    Baghani, Hamid Reza
    Nasrollahi, Shiva
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 183
  • [4] Bello O M., 2020, Int. J. Emerg. Technol, V11, P582
  • [5] Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source
    Bouzid, Dounia
    Bert, Julien
    Dupre, Pierre-Francois
    Benhalouche, Saadia
    Pradier, Olivier
    Boussion, Nicolas
    Visvikis, Dimitris
    [J]. ACTA ONCOLOGICA, 2015, 54 (10) : 1788 - 1795
  • [6] Effects of soil moisture variations on the neutron spectra measured above ground: feasibility of a soil moisture monitor system based on neutron moderating cylinders
    Calamida, A.
    Fontanilla, A.
    Russo, L.
    Pietropaolo, A.
    Pacheco, M. A. Caballero
    Domingo, C.
    Ayad, R.
    Alatawi, M. S.
    Bedogni, R.
    [J]. EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (03)
  • [7] Treatment Planning in Intraoperative Radiation Therapy (IORT): Where Should We Go?
    Cavedon, Carlo
    Mazzarotto, Renzo
    [J]. CANCERS, 2022, 14 (14)
  • [8] Sensitivity and uncertainty analysis of the first core of the DNRR using MCNP6 and new nuclear data libraries
    Chu, Thoi-Nam
    Phan, Giang T. T.
    Tran, Le Quang Linh
    Bui, Thi Hong
    Do, Quang Binh
    Dau, Duc-Tu
    Nguyen, Kien-Cuong
    Nguyen, Nhi-Dien
    Nguyen, Huu-Tiep
    Hoang, Van-Khanh
    Vu, Thanh Mai
    Tran, Hoai-Nam
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2024, 419
  • [9] An alternative method for calculation of half-value layers without the knowledge of attenuation coefficient
    Hassanpour, Mehdi
    Hassanpour, Marzieh
    Khandaker, Mayeen Uddin
    Faruque, Mohammad Rashed Iqbal
    Alshahrani, B.
    Osman, Hamid
    [J]. APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [10] Present state and issues in IORT Physics
    Hensley, Frank W.
    [J]. RADIATION ONCOLOGY, 2017, 12