Level-specific comparison of 3D navigated and robotic arm-guided screw placement: an accuracy assessment of 1210 pedicle screws in lumbar surgery

被引:6
作者
Asada, Tomoyuki [1 ,2 ]
Subramanian, Tejas [1 ,3 ]
Simon, Chad Z. [1 ]
Singh, Nishtha [1 ]
Hirase, Takashi [1 ]
Araghi, Kasra [1 ]
Lu, Amy Z. [1 ,3 ]
Mai, Eric [1 ,3 ]
Kim, Yeo Eun [1 ,3 ]
Tuma, Olivia [1 ]
Allen, Myles R. J. [1 ]
Kim, Eric [1 ,3 ]
Korsun, Maximilian [1 ]
Zhang, Joshua [1 ]
Kwas, Cole [1 ]
机构
[1] Hosp Special Surg, 535 E 70th St, New York, NY 10021 USA
[2] Univ Tsukuba, Inst Med, Dept Orthopaed Surg, Tsukuba, Japan
[3] Weill Cornell Med Coll, 1300 York Ave, New York, NY 10065 USA
关键词
Mis placement; Minimally invasive spine surgery; Patient safety; Pedicle screw; Robotic screw placement; 3D Navigation; Robotic arm; Screw breach; SPINE;
D O I
10.1016/j.spinee.2024.05.013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Robotic spine surgery, utilizing 3D imaging and robotic arms, has been shown to improve the accuracy of pedicle screw placement compared to conventional methods, although its superiority remains under debate. There are few studies evaluating the accuracy of 3D navigated versus robotic-guided screw placement across lumbar levels, addressing anatomical challenges to refine surgical strategies and patient safety. PURPOSE: This study aims to investigate the pedicle screw placement accuracy between 3D navigation and robotic arm-guided systems across distinct lumbar levels. STUDY DESIGN: A retrospective review of a prospectively collected registry. PATIENT SAMPLE: Patients undergoing fusion surgery with pedicle screw placement in the prone position, using either via 3D image navigation only or robotic arm guidance. OUTCOME MEASURE: Radiographical screw accuracy was assessed by the postoperative computed tomography (CT) according to the Gertzbein-Robbins classification, particularly focused on accuracy at different lumbar levels. METHODS: Accuracy of screw placement in the 3D navigation (Nav group) and robotic arm guidance (Robo group) was compared using Chi-squared test/Fisher's exact test with effect size measured by Cramer's V, both overall and at each specific lumbosacral spinal level. RESULTS: A total of 321 patients were included (Nav, 157; Robo, 189) and evaluated 1210 screws (Nav, 651; Robo 559). The Robo group demonstrated significantly higher overall accuracy (98.6 vs 93.9%; p<.001, V=0.25). This difference of no breach screw rate was signified the most at the L3 level (No breach screw: Robo 91.3 vs 57.8%, p<.001, V=0.35) followed by L4 (89.6 vs 64.7%, p<.001, < .001, V=0.28), and L5 (92.0 vs 74.5%, p<.001, < .001, V=0.22). However, screw accuracy at S1 was not significant between the groups (81.1 vs 72.0%, V=0.10). CONCLUSION: This study highlights the enhanced accuracy of robotic arm-guided systems compared to 3D navigation for pedicle screw placement in lumbar fusion surgeries, especially at the L3, L4, and L5 levels. However, at the S1 level, both systems exhibit similar effectiveness, underscoring the importance of understanding each system's specific advantages for optimization of surgical complications. (c) 2024 Published by Elsevier Inc.
引用
收藏
页码:1872 / 1880
页数:9
相关论文
共 32 条
[1]   Safety of robotic-assisted screw placement for spine surgery: Experience from the initial 125 cases [J].
Akazawa, Tsutomu ;
Torii, Yoshiaki ;
Ueno, Jun ;
Umehara, Tasuku ;
Iinuma, Masahiro ;
Yoshida, Atsuhiro ;
Tomochika, Ken ;
Ohtori, Seiji ;
Niki, Hisateru .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (04) :933-938
[2]   Overview of Robotic Technology in Spine Surgery [J].
Alluri, Ram K. ;
Avrumova, Fedan ;
Sivaganesan, Ahilan ;
Vaishnav, Avani S. ;
Lebl, Darren R. ;
Qureshi, Sheeraz A. .
HSS JOURNAL, 2021, 17 (03) :308-316
[3]   Robot-navigated pedicle screw insertion can reduce intraoperative blood loss and length of hospital stay: analysis of 1,633 patients utilizing propensity score matching [J].
Asada, Tomoyuki ;
Simon, Chad Z. ;
Lu, Amy Z. ;
Adida, Samuel ;
Dupont, Marcel ;
Parel, Philip M. ;
Zhang, Joshua ;
Bhargava, Satyaj ;
Morse, Kyle W. ;
Dowdell, James E. ;
Iyer, Sravisht ;
Qureshi, Sheeraz A. .
SPINE JOURNAL, 2024, 24 (01) :118-124
[4]  
Avrumova Fedan, 2021, J Spine Surg, V7, P141, DOI 10.21037/jss-20-687
[5]   THE EFFECTS OF PEDICLE SCREW FIT - AN IN-VITRO STUDY [J].
BRANTLEY, AGU ;
MAYFIELD, JK ;
KOENEMAN, JB ;
CLARK, KR .
SPINE, 1994, 19 (15) :1752-1758
[6]   Radiological and Clinical Differences between Tinavi Orthopedic Robot and O-Arm Navigation System in Thoracolumbar Screw Implantation for Reconstruction of Spinal Stability [J].
Du, Jinpeng ;
Gao, Lin ;
Huang, Dageng ;
Shan, Lequn ;
Wang, Wentao ;
Fan, Yong ;
Hao, Dingjun ;
Yan, Liang .
MEDICAL SCIENCE MONITOR, 2020, 26
[7]   Robotic-Assisted Spinal Surgery Current Generation Instrumentation and New Applications [J].
Elswick, Clay M. ;
Strong, Michael J. ;
Joseph, Jacob R. ;
Saadeh, Yamaan ;
Oppenlander, Mark ;
Park, Paul .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2020, 31 (01) :103-+
[8]   The REDCap consortium: Building an international community of software platform partners [J].
Harris, Paul A. ;
Taylor, Robert ;
Minor, Brenda L. ;
Elliott, Veida ;
Fernandez, Michelle ;
O'Neal, Lindsay ;
McLeod, Laura ;
Delacqua, Giovanni ;
Delacqua, Francesco ;
Kirby, Jacqueline ;
Duda, Stephany N. .
JOURNAL OF BIOMEDICAL INFORMATICS, 2019, 95
[9]   Research electronic data capture (REDCap)-A metadata-driven methodology and workflow process for providing translational research informatics support [J].
Harris, Paul A. ;
Taylor, Robert ;
Thielke, Robert ;
Payne, Jonathon ;
Gonzalez, Nathaniel ;
Conde, Jose G. .
JOURNAL OF BIOMEDICAL INFORMATICS, 2009, 42 (02) :377-381
[10]   Robotic-guided placement of cervical pedicle screws: feasibility and accuracy [J].
Kisinde, Stanley ;
Hu, Xiaobang ;
Hesselbacher, Shea ;
Satin, Alexander M. ;
Lieberman, Isador H. .
EUROPEAN SPINE JOURNAL, 2022, 31 (03) :693-701