Improved hydrophobic subtraction model of reversed-phase liquid chromatography selectivity based on a large dataset with a focus on isomer selectivity

被引:3
作者
Rutan, Sarah C. [1 ]
Kempen, Trevor [2 ]
Dahlseid, Tina [2 ]
Kruger, Zachary [2 ]
Pirok, Bob [2 ]
Shackman, Jonathan G. [3 ]
Zhou, Yiyang [3 ]
Wang, Qinggang [3 ]
Stoll, Dwight R. [2 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Box 842006, Richmond, VA 23284 USA
[2] Gustavus Adolphus Coll, Dept Chem, 800 W Coll Ave, St Peter, MN 56082 USA
[3] Bristol Myers Squibb, Chem Proc Dev, 1 Squibb Dr, New Brunswick, NJ 08903 USA
基金
美国国家科学基金会;
关键词
Hydrophobic subtraction model; Isomer selectivity; Pharmaceuticals; Principal components analysis; SOLVATION ENERGY RELATIONSHIPS; COLUMN SELECTIVITY; RETENTION PREDICTION; SHAPE SELECTIVITY; CROSS-VALIDATION; PERFORMANCE; SOLVENT;
D O I
10.1016/j.chroma.2024.465127
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reversed-phase (RP) liquid chromatography is an important tool for the characterization of materials and products in the pharmaceutical industry. Method development is still challenging in this application space, particularly when dealing with closely-related compounds. Models of chromatographic selectivity are useful for predicting which columns out of the hundreds that are available are likely to have very similar, or different, selectivity for the application at hand. The hydrophobic subtraction model (HSM1) has been widely employed for this purpose; the column database for this model currently stands at 750 columns. In previous work we explored a refinement of the original HSM1 (HSM2) and found that increasing the size of the dataset used to train the model dramatically reduced the number of gross errors in predictions of selectivity made using the model. In this paper we describe further work in this direction (HSM3), this time based on a much larger solute set (1014 solute/stationary phase combinations) containing selectivities for compounds covering a broader range of physicochemical properties compared to HSM1. The molecular weight range was doubled, and the range of the logarithm of the octanol/water partition coefficients was increased slightly. The number of active pharmaceutical ingredients and related synthetic intermediates and impurities was increased from four to 28, and ten pairs of closely related structures (e.g., geometric and cis-/trans- isomers) were included. The HSM3 model is based on retention measurements for 75 compounds using 13 RP stationary phases and a mobile phase of 40/60 acetonitrile/25 mM ammonium formate buffer at pH 3.2. This data-driven model produced predictions of ln alpha (chromatographic selectivity using ethylbenzene as the reference compound) with average absolute errors of approximately 0.033, which corresponds to errors in alpha of about 3 %. In some cases, the prediction of the trans-/ cis- selectivities for positional and geometric isomers was relatively accurate, and the driving forces for the observed selectivity could be inferred by examination of the relative magnitudes of the terms in the HSM3 model. For some geometric isomer pairs the interactions mainly responsible for the observed selectivities could not be rationalized due to large uncertainties for particular terms in the model. This suggests that more work is needed in the future to explore other HSM-type models and continue expanding the training dataset in order to continue improving the predictive accuracy of these models. Additionally, we release with this paper a much larger data set (43,329 total retention measurements) at multiple mobile phase compositions, to enable other researchers to pursue their own lines of inquiry related to RP selectivity.
引用
收藏
页数:15
相关论文
共 41 条
[1]   Molecular modeling and prediction accuracy in Quantitative Structure-Retention Relationship calculations for chromatography [J].
Amos, Ruth I. J. ;
Haddad, Paul R. ;
Szucs, Roman ;
Dolan, John W. ;
Pohl, Christopher A. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 105 :352-359
[2]  
[Anonymous], 2020, PQRI Database
[3]  
[Anonymous], 2020, Column Selectivity Database
[4]   A Database of Experimentally Derived and Estimated Octanol-Air Partition Ratios (KOA) [J].
Baskaran, Sivani ;
Lei, Ying Duan ;
Wania, Frank .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 2021, 50 (04)
[5]   Cross-validation of component models: A critical look at current methods [J].
Bro, R. ;
Kjeldahl, K. ;
Smilde, A. K. ;
Kiers, H. A. L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (05) :1241-1251
[6]   Changes in the cis-trans isomer selectivity of a reversed-phase liquid chromatography column during use with acidic mobile phase conditions [J].
Dahlseid, Tina ;
Florea, Alexandru ;
Schulte, Grace ;
Cash, Kathryn ;
Xu, Xuejun ;
Tattersall, Peter ;
Wang, Qinggang ;
Stoll, Dwight .
JOURNAL OF CHROMATOGRAPHY A, 2023, 1708
[7]  
Dolan JW, 2016, LC GC N AM, V34, P730
[8]   Evaluation of two approaches to characterise liquid chromatographic columns using pharmaceutical separations [J].
Dragovic, Sanja ;
Haghedooren, Erik ;
Nemeth, Tamas ;
Palabiyik, I. Murat ;
Hoogmartens, Jos ;
Adams, Erwin .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3210-3216
[9]   Column selectivity in reversed-phase liquid chromatography - IV. Type-B alkyl-silica columns [J].
Gilroy, JJ ;
Dolan, JW ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :757-778
[10]   Identifying orthogonal and similar reversed phase liquid chromatography stationary phases using the system selectivity cube and the hydrophobic subtraction model [J].
Johnson, Andrew R. ;
Johnson, Carrie M. ;
Stoll, Dwight R. ;
Vitha, Mark F. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 :62-82