Ectasia Detection by Anterior Segment Optical Coherence Tomography in Scheimpflug Tomographically Normal Keratoconus Fellow Eyes

被引:1
|
作者
Naujokaitis, Tadas [1 ]
Augustin, Victor A. [1 ]
Son, Hyeck-Soo [1 ]
Koeppe, Maximilian [1 ]
Kovalchuk, Bogdana [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
机构
[1] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, Heidelberg, Germany
关键词
keratoconus; Pentacam; Anterion; corneal tomography; ectasia detection; CORNEAL TOMOGRAPHY; RISK-ASSESSMENT; REPEATABILITY; INDEXES; SYSTEM;
D O I
10.1097/ICO.0000000000003518
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). Methods: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambr & oacute;sio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. Results: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. Conclusions: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 50 条
  • [31] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Alexandra Bograd
    Isabelle Himmel
    Isabel B. Pfister
    Theo G. Seiler
    Beatrice E. Frueh
    Christoph Tappeiner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 891 - 901
  • [32] Repeatability and agreement of a Scheimpflug-Placido tomography and a Partial Coherence Interferometer in keratoconus and control eyes
    Ozkan, Yaprak
    Gokcinar, Nesrin Buyuktortop
    INTERNATIONAL OPHTHALMOLOGY, 2025, 45 (01)
  • [33] Comparative analysis of the relationship between anterior and posterior corneal shape analyzed by Scheimpflug photography in normal and keratoconus eyes
    Montalban, Raul
    Alio, Jorge L.
    Javaloy, Jaime
    Pinero, David P.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (06) : 1547 - 1555
  • [34] Keratoconus Diagnosis Using Anterior Segment Polarization-Sensitive Optical Coherence Tomography
    Fukuda, Shinichi
    Yamanari, Masahiro
    Lim, Yiheng
    Hoshi, Sujin
    Beheregaray, Simone
    Oshika, Tetsuro
    Yasuno, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (02) : 1384 - 1391
  • [35] Inter-changeability Between Anterior Segment Optical Coherence Tomography and Scheimpflug Imaging in the Evaluation of Corneal Opacity
    Mounir, Amr
    Abdellah, Marwa Mahmoud
    Zidan, Omar Fawzy
    Mostafa, Engy Mohamed
    OPEN OPHTHALMOLOGY JOURNAL, 2022, 16
  • [36] Corneal Epithelial Mapping Characteristics in Normal Eyes Using Anterior Segment Spectral Domain Optical Coherence Tomography
    Abusamak, Mohammad
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (03):
  • [37] Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography
    Hashemi, Hassan
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Momeni-Moghaddam, Hamed
    Khabazkhoob, Mehdi
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2022, 34 (02): : 216 - 222
  • [38] Combinations of Scheimpflug tomography, ocular coherence tomography and air-puff tonometry improve the detection of keratoconus
    Lu, Nan-Ji
    Koppen, Carina
    Hafezi, Farhad
    Dhubhghaill, Sorcha Ni
    Aslanides, Ioannis M.
    Wang, Qin-Mei
    Cui, Le-Le
    Rozema, Jos J.
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (03)
  • [39] Dissecting the Profile of Corneal Thickness With Keratoconus Progression Based on Anterior Segment Optical Coherence Tomography
    Dong, Yanling
    Li, Dongfang
    Guo, Zhen
    Liu, Yang
    Lin, Ping
    Lv, Bin
    Lv, Chuanfeng
    Xie, Guotong
    Xie, Lixin
    FRONTIERS IN NEUROSCIENCE, 2022, 15
  • [40] Prediction of keratoconus progression using deep learning of anterior segment optical coherence tomography maps
    Kamiya, Kazutaka
    Ayatsuka, Yuji
    Kato, Yudai
    Shoji, Nobuyuki
    Miyai, Takashi
    Ishii, Hitoha
    Mori, Yosai
    Miyata, Kazunori
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (16)