Ectasia Detection by Anterior Segment Optical Coherence Tomography in Scheimpflug Tomographically Normal Keratoconus Fellow Eyes

被引:1
|
作者
Naujokaitis, Tadas [1 ]
Augustin, Victor A. [1 ]
Son, Hyeck-Soo [1 ]
Koeppe, Maximilian [1 ]
Kovalchuk, Bogdana [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ]
机构
[1] Heidelberg Univ, Int Vis Correct Res Ctr IVCRC, Dept Ophthalmol, Heidelberg, Germany
关键词
keratoconus; Pentacam; Anterion; corneal tomography; ectasia detection; CORNEAL TOMOGRAPHY; RISK-ASSESSMENT; REPEATABILITY; INDEXES; SYSTEM;
D O I
10.1097/ICO.0000000000003518
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). Methods: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambr & oacute;sio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. Results: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. Conclusions: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 50 条
  • [21] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Robert Herber
    Janine Lenk
    Lutz E. Pillunat
    Frederik Raiskup
    Eye and Vision, 9
  • [22] Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device
    Safarzadeh, Masoud
    Nasiri, Nader
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (03): : 106 - 111
  • [23] Evaluation of CorvisST biomechanical parameters and anterior segment optical coherence tomography for diagnosing forme fruste keratoconus
    Shiga, Suguru
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    ACTA OPHTHALMOLOGICA, 2021, 99 (06) : 644 - 651
  • [24] Comparison of Anterior Chamber Depth of Normal and Keratoconus Eyes Using Scheimpflug Photography
    Edmonds, Charles R.
    Wung, Shu-Fen
    Pemberton, Bart
    Surrett, Steven
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 120 - 122
  • [25] Evaluation of corneal topography and tomography in fellow eyes of unilateral keratoconus patients for early detection of subclinical keratoconus
    Thulasidas, Mithun
    Teotia, Prateek
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2415 - 2420
  • [26] Repeatability and reliability of semi-automated anterior segment-optical coherence tomography imaging compared to manual analysis in normal and keratoconus eyes
    Lin, Anna
    Mohammed, Isa
    Munir, Wuqaas
    Munir, Saleha
    Maripudi, Snehaa
    Wei, Libby
    Alexander, Janet
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 5063 - 5069
  • [27] Repeatability and reliability of semi-automated anterior segment-optical coherence tomography imaging compared to manual analysis in normal and keratoconus eyes
    Anna N. Lin
    Isa S. K. Mohammed
    Wuqaas M. Munir
    Saleha Z. Munir
    Snehaa Maripudi
    Libby Wei
    Janet L. Alexander
    International Ophthalmology, 2023, 43 : 5063 - 5069
  • [28] Keratoconus detection using deep learning of colour-coded maps with anterior segment optical coherence tomography: a diagnostic accuracy study
    Kamiya, Kazutaka
    Ayatsuka, Yuji
    Kato, Yudai
    Fujimura, Fusako
    Takahashi, Masahide
    Shoji, Nobuyuki
    Mori, Yosai
    Miyata, Kazunori
    BMJ OPEN, 2019, 9 (09):
  • [29] Tear meniscus particle analysis with anterior segment optical coherence tomography in keratoconus
    Seyyar, Sevim Ayca
    Buyukbayram, Saban
    Soysal, Gizem Gurbostan
    Ayla, Serhat
    Dogan, Levent
    Tokuc, Ecem Onder
    Mercanli, Murat
    Mete, Alper
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (08) : 1136 - 1141
  • [30] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822