Transgranular stress corrosion cracking of 304L stainless steel pipe clamps in direct use geothermal water heating applications

被引:13
作者
Hurley, Michael F. [1 ,3 ]
Olson, Christopher R. [1 ]
Ward, Logan J. [1 ]
Jaques, Brian J. [1 ,3 ]
Johnson, Kent A. [2 ]
Gunnerson, Jonathan K. [2 ]
Butt, Darryl P. [1 ,3 ]
机构
[1] Boise State Univ, Boise, ID 83725 USA
[2] City Boise Geothermal Dept, Boise, ID 83702 USA
[3] Ctr Adv Energy Studies, Idaho Falls, ID 83415 USA
关键词
Stainless steel; Stress corrosion cracking; Transgranular; Geothermal; Chloride;
D O I
10.1016/j.engfailanal.2013.05.015
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Direct use geothermal heating relies on heat extracted from naturally occurring geothermal water sources to provide heating needs for commercial and residential use. The city of Boise, Idaho maintains the largest district geothermal heating system in the United States, utilizing a source of geothermal water at 80 degrees C. 304 Stainless steel (UNS S30400) pipe clamps are used throughout the system as repair seals and for new service connections. Occasionally unexpected fracture of the stainless steel clamps occurs with time-in-service periods as short as 1 year. A failure analysis was conducted, including visual, microstructural, compositional, and mechanical characterization, to determine the cause and source of the degradation. Cracking of the clamps was limited to localized regions with the remainder of the clamp unaffected. Branched, brittle cracks were observed in the failure region and exhibited transgranular propagation. Based on the temperature, available moisture, stress level, and type of material used it was determined that the likely cause of failure was neutral pH, dilute chloride-induced stress corrosion cracking. Based on this failure analysis, geothermal or other buried heated water systems must consider protective measures or more SCC-resistant materials to prevent susceptible conditions from developing, compared to conventional water systems, to ensure maximum lifetime performance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:336 / 346
页数:11
相关论文
共 19 条
[1]  
[Anonymous], ISI PUBLICATION
[2]  
Bloomquist R. G., 2008, INT CTR SCI HIGH TEC
[3]  
Combrade P., 2010, STRESS CORR CRACK NU
[4]  
Johnson KA, 2012, CITY BOISE GEOTH SYS, V13
[5]  
Jones D.A., 2005, PRINCIPLES PREVENTIO
[6]  
Korb LJ, 2008, ASM HDB CORROSION, V13
[7]  
Lampman S R, 1996, ASM HDB FATIGUE FRAC, V19
[8]  
Lineau PJ, 1998, GEOTHERMAL DIRECT US
[9]  
Little BrendaJ., 2007, MICROBIOLOGICALLY IN
[10]   Direct utilization of geothermal energy 2010 worldwide review [J].
Lund, John W. ;
Freeston, Derek H. ;
Boyd, Tonya L. .
GEOTHERMICS, 2011, 40 (03) :159-180