Evaluation of a Benzodiazepine Immunoassay for Urine Drug Testing in Clinical Specimens

被引:0
|
作者
Ge, Mengyuan [1 ]
Alabi, Adekunle [1 ]
Kelner, Michael J. [1 ]
Fitzgerald, Robert L. [1 ]
Suhandynata, Raymond T. [1 ,2 ]
机构
[1] UC San Diego Hlth, Dept Pathol, San Diego, CA USA
[2] UC San Diego Hlth, Skaggs Sch Pharm & Pharmaceut Sci, La Jolla, CA USA
来源
JOURNAL OF APPLIED LABORATORY MEDICINE | 2024年 / 9卷 / 06期
关键词
DEVELOPED TESTS; LC-MS/MS;
D O I
10.1093/jalm/jfae083
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Benzodiazepines are commonly prescribed medications frequently linked to instances of abuse and overdose. Historically, FDA-cleared benzodiazepine urine immunoassays cross-react poorly with glucuronidated benzodiazepine metabolites, leading to false negatives. Clinical laboratories have addressed this deficiency by creating laboratory-developed tests (LDTs) that incorporate a beta-glucuronidase hydrolysis step to increase the clinical sensitivity of these assays.Methods Performance characteristics of 2 FDA-cleared benzodiazepine urine immunoassays (Benzodiazepines Plus, no glucuronidase and Benzodiazepines II, with glucuronidase; Roche Diagnostics) and a previously described benzodiazepine immunoassay LDT (with glucuronidase) were evaluated using 258 clinical urine specimens. The positive immunoassay cutoff was set at 200 ng/mL of nordiazepam and results were compared to an LC-MS/MS benzodiazepine LDT. Clinical sensitivity, specificity, precision, and immunoassay cross-reactivity were determined for all 3 immunoassays.Results The Benzodiazepines II and LDT immunoassays exhibited greater clinical sensitivity (100% and 95.2%) compared to the Benzodiazepines Plus assay (66.7%). Clinical specificity of 100% was observed for all 3 assays. Immunoassay response of the Benzodiazepines II assay was greater across the range of concentrations tested (100-1000 ng/mL) relative to the other immunoassays and was the most sensitive immunoassay for the detection of lorazepam glucuronide.Conclusions The Benzodiazepines II immunoassay demonstrated the greatest clinical and analytical sensitivity compared to the Benzodiazepines Plus and LDT immunoassays. The incorporation of beta-glucuronidase was crucial, as the Benzodiazepines II and LDT immunoassays demonstrated superior clinical sensitivity when compared to the Benzodiazepines Plus immunoassay that does not incorporate a beta-glucuronidase hydrolysis step.
引用
收藏
页码:964 / 976
页数:13
相关论文
共 50 条
  • [41] Evaluation of the Short-Term Stability of Specimens for Clinical Laboratory Testing
    Ikeda, Katsuyoshi
    Ichihara, Kiyoshi
    Hashiguchi, Teruto
    Hidaka, Yoh
    Kang, Dongchon
    Maekawa, Masato
    Matsumoto, Hiroyuki
    Matsushita, Kazuyuki
    Okubo, Shigeo
    Tsuchiya, Tatsuyuki
    Furuta, Koh
    BIOPRESERVATION AND BIOBANKING, 2015, 13 (02) : 135 - 143
  • [42] ASSOCIATION OF THE PATIENTS' DIRECT ADDITION OF BUPRENORPHINE TO URINE SPECIMENS WITH CLINICAL FACTORS FROM A NATIONAL URINE DRUG TEST DATABASE
    Pytell, Jarratt
    Whitley, Penn
    Passik, Steven
    Bundy, William L.
    Dawson, Eric
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2023, 38 : S305 - S306
  • [43] Alternative specimens for workplace drug testing
    Caplan, YH
    Goldberger, BA
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (05) : 396 - 399
  • [44] Urine drug testing in the evaluation of sleepy patients undergoing polysomnography and multiple sleep latency testing
    Bonakis, A.
    Howard, R.
    Simon de, Lacy
    Kosky, C.
    Williams, A. J.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (03): : 352 - 352
  • [45] Large dose sertraline ingestion associated with a false-positive urine immunoassay for benzodiazepine
    Bernardo, Lindsay
    Patel, Khushbu
    Chen, Aaron
    Osterhoudt, Kevin
    CLINICAL TOXICOLOGY, 2022, 60 : 111 - 112
  • [46] Prevalence of Cannabidiol, Δ9- and Δ8-Tetrahydrocannabinol and Metabolites in Workplace Drug Testing Urine Specimens
    Vikingsson, Svante
    Winecker, Ruth E.
    Cone, Edward J.
    Kuntz, David J.
    Dorsey, Brian
    Jacques, Martin
    Senter, Melanie
    Flegel, Ronald R.
    Hayes, Eugene D.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2022, 46 (08) : 866 - 874
  • [47] PRESUMPTIVE IDENTIFICATION OF STAPHYLOCOCCUS SAPROPHYTICUS FROM URINE SPECIMENS BY COLONY APPEARANCE AND COAGULASE TESTING - AN EVALUATION
    LOO, SYT
    ADAM, AL
    SCOTTOLINI, AG
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1984, 81 (05) : 647 - 650
  • [48] PROCEDURES FOR TESTING URINE SPECIMENS DRIED ON FILTER PAPER
    BERRY, HK
    CLINICAL CHEMISTRY, 1959, 5 (06) : 603 - 608
  • [49] REAGENT STRIP TESTING OF ANTENATAL URINE SPECIMENS FOR INFECTION
    ETHERINGTON, IJ
    JAMES, DK
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (09): : 806 - 808
  • [50] CLINICAL LABORATORY EVALUATION OF AUTOMATED MICROBIAL DETECTION-IDENTIFICATION SYSTEM IN ANALYSIS OF CLINICAL URINE SPECIMENS
    ISENBERG, HD
    GAVAN, TL
    SONNENWIRTH, A
    TAYLOR, WI
    WASHINGTON, JA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1979, 10 (02) : 226 - 230