Investigation of Partial Discharge Transformation Characteristics in Polyimide (PI) Insulations under High-Frequency Electric Stress

被引:1
|
作者
Ayubi, Bilal Iqbal [1 ]
Zhang, Li [1 ]
Zhou, Shengrui [1 ]
Wang, Yiwei [1 ]
Zou, Liang [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
partial discharge (PD); polyimide (PI); high-frequency insulation; high-frequency power transformers (HFPTs); plasma model; TEMPERATURE; SIMULATION; PRESSURE;
D O I
10.3390/polym16172450
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This research delves into the primary issue of polyimide (PI) insulation failures in high-frequency power transformers (HFPTs) by scrutinizing partial discharge development under high-frequency electrical stress. This study employs an experimental approach coupled with a plasma simulation model for a ball-sphere electrode structure. The simulation model integrates the particle transport equation, Poisson equation, and complex chemical reactions to ascertain microscopic parameters, including plasma distribution, electric field, electron density, electron temperature, surface, and space charge distribution. The effect of the voltage polarity and electrical energy on the PD process is also discussed. The contact point plays a pivotal role in triggering partial discharges and culminating in the breakdown of PI insulation. Asymmetry phenomena were found between positive and negative half-cycles by analyzing the PD data stage by stage. A significant number of PDs increased at every stage and the PD amplitude was higher during the negative cycle at the initial stage, but in later stages, the PD amplitude was found to be higher in the positive half-cycle, and scanning electron microscopy (SEM) revealed that the maximum damage occurred near the contact point junction. The simulation results show that the plasma initially accumulates the electron density near the contact point junction. Under the action of the electric field, plasma starts traveling at the PI surface outward from the contact point. Before the PD activity, all parameters have higher values in the plasma head. The microscopic parameters reveal maximum values near the contact point junction, during PD activities where significant damage takes place. These parameter distributions exhibit a decreasing trend over time as when the PD activity ends. The model's predictions are consistent with the experimental data. The paper lays the foundation for future research in polymer insulation design under high-frequency electrical stress.
引用
收藏
页数:18
相关论文
共 41 条
  • [31] Surface Partial Discharge Characteristics Under Repeated Positive Triangular High Voltages (1 kV/s)
    Mikropoulos, Pantelis N.
    Samaras, Pavlos K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) : 958 - 966
  • [32] Partial Discharge Behaviors Excited by High-Frequency Square Pulse Voltage in Cast Resin Insulation With Thermal-Induced Defect
    Shang, Xingyu
    Pang, Lei
    Bu, Qinhao
    Wu, Zhicheng
    Zhang, Qiaogen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (01) : 40 - 49
  • [33] Emission Spectrum Analysis of Two Typical Partial Discharge Forms Under High Frequency Square Wave Voltages
    Zhao, Yikun
    Li, Yanfei
    Li, Kang
    Han, Dong
    Qiu, Zongjia
    Zhang, Guoqiang
    IEEE ACCESS, 2020, 8 : 219946 - 219954
  • [34] Partial Discharge Characteristics of Biaxially Oriented Polypropylene Film Under Nanosecond Pulse Voltage With High Rise Rate
    Mi, Yan
    Chen, Yong
    Liu, Canhui
    Zhu, Yakui
    Liao, Ruijin
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (02) : 498 - 506
  • [35] High-Temperature Partial Discharge Characteristics of Power Module Packaging Insulation Under Square Pulse With High Dv/Dt Based on Down-Mixing Method
    Ding, Yi
    Wang, Yalin
    Sun, Hao
    Yin, Yi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (07) : 7334 - 7342
  • [36] Erosion degradation characteristics of a linear electro-hydrostatic actuator under a high-frequency turbulent flow field
    Li, Yuan
    Wang, Shaoping
    Tomovic, Mileta M.
    Zhang, Chao
    CHINESE JOURNAL OF AERONAUTICS, 2018, 31 (05) : 914 - 926
  • [37] Study on Partial Discharge Characteristics of Severe Non-uniform Electric Field in SF6 Under Negative DC Voltage
    Pang P.
    Sun Z.
    Zhang Q.
    Han X.
    Hou Z.
    Li J.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (04): : 1093 - 1100
  • [38] Partial Discharge Characterization of Solid-Dielectric-Based Transformer Under High Frequency High dv/dt PWM Voltage for MV Applications
    Guo, Zhehui
    Li, Hui
    Cheetham, Peter
    Guvvala, Nagaraju
    2023 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2023, : 301 - 305
  • [39] Partial Discharge Characteristics of SF6 and SF6/N2 in Nonuniform Electric Field Under Negative DC Voltage
    Han, Xutao
    Zhang, Xuanrui
    Wang, Haotian
    Sun, Yuan
    Zhou, Yang
    Li, Junhao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (01) : 131 - 138
  • [40] Characteristics of Generic Dielectric Materials and Char as Bed Materials of a Dielectric Barrier Discharge Reactor under High Temperature and Wide Frequency Range
    Arumugam, Saravanakumar
    Schroeder, Philipp
    Schoenemann, Thomas
    Neubauer, York
    ENERGIES, 2022, 15 (23)