Investigation of Partial Discharge Transformation Characteristics in Polyimide (PI) Insulations under High-Frequency Electric Stress

被引:1
|
作者
Ayubi, Bilal Iqbal [1 ]
Zhang, Li [1 ]
Zhou, Shengrui [1 ]
Wang, Yiwei [1 ]
Zou, Liang [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
partial discharge (PD); polyimide (PI); high-frequency insulation; high-frequency power transformers (HFPTs); plasma model; TEMPERATURE; SIMULATION; PRESSURE;
D O I
10.3390/polym16172450
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This research delves into the primary issue of polyimide (PI) insulation failures in high-frequency power transformers (HFPTs) by scrutinizing partial discharge development under high-frequency electrical stress. This study employs an experimental approach coupled with a plasma simulation model for a ball-sphere electrode structure. The simulation model integrates the particle transport equation, Poisson equation, and complex chemical reactions to ascertain microscopic parameters, including plasma distribution, electric field, electron density, electron temperature, surface, and space charge distribution. The effect of the voltage polarity and electrical energy on the PD process is also discussed. The contact point plays a pivotal role in triggering partial discharges and culminating in the breakdown of PI insulation. Asymmetry phenomena were found between positive and negative half-cycles by analyzing the PD data stage by stage. A significant number of PDs increased at every stage and the PD amplitude was higher during the negative cycle at the initial stage, but in later stages, the PD amplitude was found to be higher in the positive half-cycle, and scanning electron microscopy (SEM) revealed that the maximum damage occurred near the contact point junction. The simulation results show that the plasma initially accumulates the electron density near the contact point junction. Under the action of the electric field, plasma starts traveling at the PI surface outward from the contact point. Before the PD activity, all parameters have higher values in the plasma head. The microscopic parameters reveal maximum values near the contact point junction, during PD activities where significant damage takes place. These parameter distributions exhibit a decreasing trend over time as when the PD activity ends. The model's predictions are consistent with the experimental data. The paper lays the foundation for future research in polymer insulation design under high-frequency electrical stress.
引用
收藏
页数:18
相关论文
共 41 条
  • [21] Numerical investigation of high-frequency pulsating electrohydrodynamic jet at low electric Bond numbers
    Guan, Yin
    Wu, Shuang
    Wang, Mengduo
    Tian, Yu
    Yu, Chuanpeng
    Lai, Wuxing
    Huang, YongAn
    PHYSICS OF FLUIDS, 2022, 34 (01)
  • [22] An Investigation into the Characteristics of a New High-frequency Electro-hydraulic Flutter Device
    Jin, Defeng
    Xing, Tong
    Fu, Liang
    Yang, Yongshuai
    ADVANCES IN ENGINEERING DESIGN AND OPTIMIZATION III, PTS 1 AND 2, 2012, 201-202 : 370 - 374
  • [23] Investigation into the Characteristics of Nanoporous Carbon/Silica-Nickel Nanocomposite for high-frequency Applications
    Sayari, F.
    Ben Mansour, N.
    Kraini, M.
    Wederni, M. A.
    Hjiri, M.
    Aouaini, F.
    Sharma, A.
    El Mir, L.
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2025, 35 (01) : 98 - 108
  • [24] Thermal Characteristics Investigation of Lithium-Ion Battery Under High-Frequency AC Excitation in Low-Temperature Environment
    Hu, Zhongxiaobang
    Li, Yang
    Liu, Furong
    Zhao, Bo
    Li, Weibo
    Yang, Ruixin
    Xie, Changjun
    Shi, Ying
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2022, 8 (01) : 407 - 419
  • [25] Optical Emission Characteristics of Atmospheric-Pressure Nonequilibrium Microwave Discharge and High-Frequency DC Pulse Discharge Plasma Jets
    Yuji, Toshifumi
    Fujii, Shuitsu
    Mungkung, Narong
    Akatsuka, Hiroshi
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (06) : 839 - 845
  • [26] Propagation and Partial Discharge Characteristics of Electrical Trees in XLPE Cable Under High Temperatures and High Gas Pressures
    Zhou L.
    Qiu Q.
    Cheng R.
    Hu J.
    Cai J.
    Zhou, Lijun (ljzhou10@163.com), 2018, Science Press (44): : 1421 - 1427
  • [27] A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer
    Lai, Zekai
    Mu, Haibao
    Hua, Xiaochang
    Zhou, Chenhui
    Lin, Haofan
    Shao, Xianjun
    Zhang, Guanjun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) : 1181 - 1190
  • [28] Partial Discharge Initial Characteristics of SF6/N2 Mixture in Extremely Inhomogeneous Electric Field under DC High Voltage
    Pang P.
    Sun Z.
    Zhang Q.
    Hou Z.
    Zhang X.
    Sun S.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2019, 53 (04): : 44 - 50
  • [29] Mechanical characteristics and pore evolution of red sandstone under ultrasonic high-frequency vibration excitation
    Zhang, Lei
    Wang, Xufeng
    Wang, Jiyao
    Yang, Zhanbiao
    AIP ADVANCES, 2021, 11 (05)
  • [30] Active Control Strategy of Partial Discharge for Insulation of High-Power High-Voltage High-Frequency Transformers (H3Ts)
    Jiang, Jun
    Chen, Wu
    Song, Yu
    Shen, Zhan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (07) : 7521 - 7524