Investigation of Partial Discharge Transformation Characteristics in Polyimide (PI) Insulations under High-Frequency Electric Stress

被引:1
|
作者
Ayubi, Bilal Iqbal [1 ]
Zhang, Li [1 ]
Zhou, Shengrui [1 ]
Wang, Yiwei [1 ]
Zou, Liang [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
partial discharge (PD); polyimide (PI); high-frequency insulation; high-frequency power transformers (HFPTs); plasma model; TEMPERATURE; SIMULATION; PRESSURE;
D O I
10.3390/polym16172450
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This research delves into the primary issue of polyimide (PI) insulation failures in high-frequency power transformers (HFPTs) by scrutinizing partial discharge development under high-frequency electrical stress. This study employs an experimental approach coupled with a plasma simulation model for a ball-sphere electrode structure. The simulation model integrates the particle transport equation, Poisson equation, and complex chemical reactions to ascertain microscopic parameters, including plasma distribution, electric field, electron density, electron temperature, surface, and space charge distribution. The effect of the voltage polarity and electrical energy on the PD process is also discussed. The contact point plays a pivotal role in triggering partial discharges and culminating in the breakdown of PI insulation. Asymmetry phenomena were found between positive and negative half-cycles by analyzing the PD data stage by stage. A significant number of PDs increased at every stage and the PD amplitude was higher during the negative cycle at the initial stage, but in later stages, the PD amplitude was found to be higher in the positive half-cycle, and scanning electron microscopy (SEM) revealed that the maximum damage occurred near the contact point junction. The simulation results show that the plasma initially accumulates the electron density near the contact point junction. Under the action of the electric field, plasma starts traveling at the PI surface outward from the contact point. Before the PD activity, all parameters have higher values in the plasma head. The microscopic parameters reveal maximum values near the contact point junction, during PD activities where significant damage takes place. These parameter distributions exhibit a decreasing trend over time as when the PD activity ends. The model's predictions are consistent with the experimental data. The paper lays the foundation for future research in polymer insulation design under high-frequency electrical stress.
引用
收藏
页数:18
相关论文
共 41 条
  • [11] Investigation of high-frequency small-signal characteristics of FETs/HEMTs
    Starikov, E.
    Shiktorov, P.
    Gruzinskis, V.
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2012, 27 (04)
  • [12] Characteristics of Partial Discharge in Oil-paper Insulation System under High Frequency Voltage
    Wang, Jian
    Li, Qingmin
    Liu, Sihua
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,
  • [13] Numerical Analysis for Negative Discharge Under High-Frequency Pulsed Voltage
    Kim, Minhee
    Cho, Yong Sung
    IEEE TRANSACTIONS ON MAGNETICS, 2025, 61 (01)
  • [14] Characterization of Partial Discharges in High-Frequency Transformer Under PWM Pulses
    Guo, Zhicheng
    Huang, Alex Q.
    Hebner, Robert E.
    Montanari, Gian Carlo
    Feng, Xianyong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (09) : 11199 - 11208
  • [15] Investigation of High-Frequency Noise Characteristics in Tensile-Strained nMOSFETs
    Wang, Sheng-Chun
    Su, Pin
    Chen, Kun-Ming
    Chen, Bo-Yuan
    Huang, Guo-Wei
    Hung, Cheng-Chou
    Huang, Sheng-Yi
    Fan, Cheng-Wen
    Tzeng, Chih-Yuh
    Chou, Sam
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2011, 58 (03) : 895 - 900
  • [16] Optical Detection and Characteristics of PCB Partial Discharge in More-Electric Aircraft Under Square Wave Voltage
    Zang, Yiming
    Niasar, Mohamad Ghaffarian
    Xu, Yongpeng
    Li, Ze
    Qian, Qinglin
    Jiang, Xiuchen
    Vaessen, Peter
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (06) : 5558 - 5567
  • [17] Partial Discharge Aging of Epoxy Insulation at Different High-Frequency Pulse Parameters and Environmental Stresses
    Shang, Xingyu
    Pang, Lei
    Bu, Qinhao
    Zhang, Qiaogen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (01) : 45 - 54
  • [18] Partial Discharge Characteristics of Polyimide Films Used in Inverter-Fed Traction Motor Under Different Temperatures
    Luo, Y.
    Wu, G. N.
    Jia, P.
    Liu, J. W.
    Wang, P.
    Cao, K. J.
    Cui, Y.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 809 - 812
  • [19] The influence of the axial heterogeneity of the plasma of high-frequency torch discharge on its electrodynamic characteristics
    Lutsenko, Yu Yu
    Vlasov, V. A.
    Zelenetskaya, E. P.
    THERMOPHYSICS AND AEROMECHANICS, 2013, 20 (01) : 115 - 120
  • [20] The influence of the axial heterogeneity of the plasma of high-frequency torch discharge on its electrodynamic characteristics
    Yu. Yu. Lutsenko
    V. A. Vlasov
    E. P. Zelenetskaya
    Thermophysics and Aeromechanics, 2013, 20 : 115 - 120