A broad-spectrum LC-MS/MS method for screening and quantification of 100 analytes in clinical and autopsy blood samples

被引:0
|
作者
Florou, Dimitra [1 ,2 ,3 ]
Di Rago, Mathew [2 ,3 ]
Orfanidis, Amvrosios [1 ,4 ]
Gerostamoulos, Dimitri
Boumba, Vassiliki A. [1 ,4 ]
机构
[1] Univ Ioannina, Fac Med, Sch Hlth Sci, Dept Forens Med & Toxicol, Univ Campus, Ioannina 45500, Greece
[2] Victorian Inst Forens Med Toxicol, 65 Kavanagh St, Melbourne, Vic 3006, Australia
[3] Monash Univ, Dept Forens Med, Melbourne, Vic 3006, Australia
[4] Univ Hosp Ioannina, Ioannina 45110, Greece
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2024年 / 1247卷
关键词
Blood; Drugs; LC-MS/MS; NPS; Forensic toxicology; PSYCHOACTIVE SUBSTANCES; WHOLE-BLOOD; MASS-SPECTROMETRY; DRUGS; EXTRACTION; SERUM;
D O I
10.1016/j.jchromb.2024.124323
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography coupled with mass spectrometry (LC-MS) has been tremendously used for screening purposes in forensic toxicology, because of their great adaptability and reasonable time/resource consumption. Herein, a fully validated method based on liquid-liquid extraction (LLE) in human whole blood, by a multiple reaction monitoring (MRM) analysis through LC-MS/MS, is described. The proposed method simultaneously detects 100 analytes (plus three deuterated internal standard compounds) belonging to many different classes, including drugs of abuse, prescription and over-the-counter drugs commonly involved in poisoning and medical malpractice cases in our territory, as well as certain new psychoactive substances (NPS) and toxic substances potentially associated with adverse effects. The optimised LLE employs one extraction step of 200 mu L blood using 0.1 M HCl methyl-tert-butyl-ether (MTBE) (acidified with concentrated HCl) proved to be suitable for the extraction of basic and neutral substances; as a reconstitution solvent a mixture of 88:12v/v, 0.1 % formic acid in 10 mM aqueous ammonium acetate, pH 3.5: 0.1 % formic acid in acetonitrile was used, yielding satisfactory recoveries for all analytes. The method was sensitive, showing low LOD/ LOQ for all substances ranging from 0.01 to 5/ 0.05-20 ng/mL, respectively. Linearity ranged between 0.05-500 ng/mL (R-2 = 0.9811-0.9995), and the inter- and intra-day precisions ranged between 3-15 % and 7-18 %, respectively. Accuracy was evaluated in terms of percentage recovery, lying within acceptable range. The matrix effect expressed as ion suppression/enhancement of each analyte was in the range +/- 25 % for all analytes. Post-preparative stability of analytes was higher than 85 %, while no carryover between runs was observed. The developed method has been successfully applied in routine toxicological analyses for the analysis of biological samples from clinical and autopsy cases.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] An accurate and robust LC-MS/MS method for the quantification of chlorfenvinphos, ethion and linuron in liver samples
    Kadar, Ali
    Peyre, Ludovic
    de Souza, Georges
    Wortham, Henri
    Doumenq, Pierre
    Rahmani, Roger
    CHEMOSPHERE, 2017, 184 : 20 - 26
  • [32] LC-MS/MS method for simultaneous quantification of Everolimus and Sirolimus
    Tancre, A. -S.
    Capron, A.
    Wallemacq, P.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2012, 27 (06): : 345 - 351
  • [33] Development and Validation of a Method to Analyze Fentanyl and Its Analogues in Postmortem Blood Samples by LC-MS/MS
    Rodrigues, Tais B.
    Matsubara, Marcio H.
    Aquino, Elvis M.
    Gianvecchio, Victor A. P.
    Morais, Damila R.
    Costa, Jose Luiz
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2024, : 1 - 8
  • [34] Concordance of Biochip-Based and LC-MS/MS Methods in Urine and Blood Samples in Screening for Amphetamine and Methamphetamine
    Akbaba, Murat
    Isir, Aysun Baransel
    DIAGNOSTICS, 2025, 15 (03)
  • [35] A Robust Procedure for Determination of Immunosuppressants Cyclosporine A and Tacrolimus in Blood Samples with Detection of LC-MS/MS
    Huo, Yumei
    Zhang, Shangqing
    Pan, Chao
    Shan, Hongbo
    Xu, Yuxuan
    Cai, Xin
    CHROMATOGRAPHIA, 2023, 86 (03) : 255 - 263
  • [36] Simultaneous quantification of centchroman and its 7-demethylated metabolite in rat dried blood spot samples using LC-MS/MS
    Lal, Jawahar
    Sharma, Nidhi
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (09) : 1089 - 1095
  • [37] LC-MS/MS method for the simultaneous quantification of thiafentanil and naltrexone in bovine muscle, liver and kidney
    Christie, Judith T.
    Bruce, Mieghan
    Pfitzer, Silke
    Laubscher, Liesel
    Raath, Jacobus P.
    Laurence, Michael
    Kellermann, Tracy
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 257
  • [38] Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma
    Rakusa, Zane Temova
    Roskar, Robert
    Andrejc, Anita Klancar
    Lusin, Tina Trdan
    Faganeli, Natasa
    Grabnar, Iztok
    Mrhar, Ales
    Kristl, Albin
    Trontelj, Jurij
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [39] An LC-MS/MS method for the simultaneous quantification of 32 steroids in human plasma
    Simkova, Marketa
    Kolatorova, Lucie
    Drasar, Pavel
    Vitku, Jana
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1201
  • [40] Screening Assay of Residual Antibiotics in Livestock Samples by LC-MS/MS
    Nakajima, Takayuki
    Sasamoto, Takeo
    Hayashi, Hiroshi
    Kanda, Maki
    Takeba, Kazue
    Kanai, Setsuko
    Kusano, Tomoko
    Matsushima, Yoko
    Takano, Ichiro
    FOOD HYGIENE AND SAFETY SCIENCE, 2012, 53 (02): : 91 - 97