Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners

被引:11
作者
Azevedo, Luis [1 ,6 ]
Marques, Tiago [2 ]
Karasan, Duygu [3 ]
Fehmer, Vincent [4 ]
Sailer, Irena [3 ]
Correia, Andre [2 ]
Gomez-Polo, Miguel [5 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[2] Univ Catolica Portuguesa UCP, Fac Dent Med, Viseu, Portugal
[3] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[5] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, Madrid, Spain
[6] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Orofacial Prostheses, S-N Plaza Ramon y Cajal, Madrid 28040, Spain
关键词
IMPRESSION TECHNIQUES; ACCURACY; PROSTHESES; PRECISION;
D O I
10.1016/j.prosdent.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The absence of fixed reference points can affect the trueness of complete arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete arch digital implant scans is still unclear. Purpose. The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete arch digital implant scans with 5 intraoral scanners (IOSs). Material and methods. Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (alpha=.05). Results. The mean +/- standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 +/- 8 pm, 53 +/- 7 pm, and 49 +/- 11 pm, respectively, with no statistically significant differences ( P=.06). Significant differences were found for the IOSs used with each technique ( P<.001). Primescan (27 +/- 4 pm cIOSs; 28 +/- 3 pm sIOSs; 31 +/- 3 pm AL-IOSs) showed significantly higher trueness than iTero 5D (47 +/- 5 pm cIOSs; 47 +/- 4 pm sIOSs; 50 +/- 6 pm AL-IOSs) ( P=.002) and TRIOS 4 (93 +/- 18 pm cIOSs; 76 +/- 18 pm sIOSs; 107 +/- 13 pm AL-IOSs) ( P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan ( P=.348 and P=.059, respectively). Conclusions. The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete arch digital implant scans. (J Prosthet Dent 2024;132:204-210)
引用
收藏
页码:204 / 210
页数:7
相关论文
共 47 条
  • [21] Three-Dimensional Evaluation of Peri-implant Soft Tissue When Tapered Implants Are Placed: Pilot Study with Implants Placed Immediately or Early Following Tooth Extraction
    Lee, Hyeonjong
    Fehmer, Vincent
    Hicklin, Stefan
    Noh, Gunwoo
    Hong, Seoung-Jin
    Sailer, Irena
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) : 1036 - 1043
  • [22] Improved digital impressions of edentulous areas
    Lee, Ju-Hyoung
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03) : 448 - 449
  • [23] Intraoral scanners in dentistry: a review of the current literature
    Mangano, Francesco
    Gandolfi, Andrea
    Luongo, Giuseppe
    Logozzo, Silvia
    [J]. BMC ORAL HEALTH, 2017, 17
  • [24] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    [J]. BMC ORAL HEALTH, 2020, 20 (01)
  • [25] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    [J]. BMC ORAL HEALTH, 2019, 19 (1)
  • [26] Digital Wear Analysis of Different CAD/CAM-Fabricated Monolithic Ceramic Implant-Supported Single Crowns Using Two Optical Scanners
    Marchand, Laurent
    Sailer, Irena
    Lee, Hyeonjong
    Mojon, Philippe
    Pitta, Joao
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) : 357 - 364
  • [27] Digital versus conventional implant impressions for partially edentulous arches: An evaluation of accuracy
    Marghalani, Amin
    Weber, Hans-Peter
    Finkelman, Matthew
    Kudara, Yukio
    El Rafie, Khaled
    Papaspyridakos, Panos
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) : 574 - 579
  • [28] Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure
    Menini, Maria
    Setti, Paolo
    Pera, Francesco
    Pera, Paolo
    Pesce, Paolo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) : 1253 - 1262
  • [29] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) : 96 - 104
  • [30] Digital vs Conventional Implant Impressions: A Systematic Review and Meta-Analysis
    Papaspyridakos, Panos
    Vazouras, Konstantinos
    Chen, Yo-wei
    Kotina, Elli
    Natto, Zuhair
    Kang, Kiho
    Chochlidakis, Konstantinos
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 660 - 678