SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI

被引:0
|
作者
Mathieu, William [1 ]
Popovic, Milica [1 ]
Farivar, Reza [2 ]
机构
[1] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
[2] McGill Univ, Dept Ophthalmol, Montreal, PQ, Canada
来源
2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024 | 2024年
关键词
MRI; RF Coils; Phased Arrays; Flexible RF Coils;
D O I
10.1109/IMBIOC60287.2024.10590301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In head MRI applications, flexible RF receive-only head coils can offer improved SNR and patient comfort. In our work, we achieve partial, but sufficient, flexibility by decomposing an average head surface into movable, semi-flexible plates that comfortably adapt to the surface of the head. As a result, we can include a larger number of smaller elements, pushing the boundary of achievable SNR while still being able to resolve brain areas. In order to test the viability of the design, we investigate the SNR variability of two 12-channel frontal plate arrays when they are adapted to fit differently sized heads. The elements were constructed on a 3D-printed thermoplastic polyurethane (TPU) flexible substrate, with conductive loops on the inside surface to minimize their distance to the head. Experiments were conducted in an MRI scanner in which a spherical phantom was imaged by the frontal plate arrays together at four positions. We demonstrate that SNR decreases, as expected, as the gap between the plates increases, but in an acceptable range. The overall range of inter-plate distance results in SNR variability of approximately 15%. These results support the overall feasibility of the larger head coil composed of eight movable plates: the mechanical gaps that would appear for larger heads would not compromise the SNR and, therefore, signal integrity and would still outperform a similar fixed-size head coil.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 50 条
  • [41] A compact 3T all HTS cryogen-free MRI system
    Parkinson, B. J.
    Slade, R. A.
    Bouloukakis, K.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2017, 30 (12)
  • [42] Improving Homogeneity for MRI RF Field at 3T Using a Huygens' Box
    Xue, Chen
    Zhou, Gabriel G. L.
    Wong, Alex M. H.
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 915 - 916
  • [43] Novel use of 3T MRI in assessment of optic nerve volume in glaucoma
    Norlina M. Ramli
    Sabrilhakim Sidek
    Fadzlina A. Rahman
    Mohammadreza Peyman
    Mimiwati Zahari
    Kartini Rahmat
    Norlisah Ramli
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 995 - 1000
  • [44] Flexible, 31-Channel Breast Coil for Enhanced Parallel Imaging Performance at 3T
    Hancu, Ileana
    Fiveland, Eric
    Park, Keith
    Giaquinto, Randy O.
    Rohling, Kenneth
    Wiesinger, Florian
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 897 - 905
  • [45] Identification of long thoracic nerve on high-resolution 3T MRI
    Lee, Susan C.
    Geannette, Christian S.
    Sneag, Darryl B.
    CLINICAL IMAGING, 2020, 64 : 97 - 102
  • [46] Intracortical Myelination within the Frontal Lobe as a Potential Biomarker for Therapeutic Effectiveness in Antipsychotics Using MRI with Selective Myelin-Lipid Suppression at 1.5T and 3T
    Tishler, Todd
    Bartzokis, George
    Alphs, Larry
    Brown, Brianne
    Yue, Yong
    Villablanca, J. P.
    Subotnik, Kenneth
    Nuechterlein, Keith
    Ellingson, Benjamin
    BIOLOGICAL PSYCHIATRY, 2017, 81 (10) : S115 - S116
  • [47] Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears
    Lee, Ro Woon
    Choi, Soo-Jung
    Lee, Man Ho
    Ahn, Jae Hong
    Shin, Dong Rock
    Kang, Chae Hoon
    Lee, Ki Won
    SKELETAL RADIOLOGY, 2016, 45 (12) : 1705 - 1715
  • [48] The circumventricular organs of the brain: conspicuity on clinical 3T MRI and a review of functional anatomy
    Horsburgh, Avril
    Massoud, Tarik F.
    SURGICAL AND RADIOLOGIC ANATOMY, 2013, 35 (04) : 343 - 349
  • [49] Quantitative proton MRI and MRS of the rat brain with a 3T clinical MR scanner
    Aradi, M.
    Steier, R.
    Bukovics, P.
    Szalay, C.
    Perlaki, G.
    Orsi, G.
    Pal, J.
    Janszky, J.
    Doczi, T.
    Schwarcz, A.
    JOURNAL OF NEURORADIOLOGY, 2011, 38 (02) : 90 - 97
  • [50] 3T MRI-based estimation of scalar cochlear implant electrode position
    Tek, F.
    Mueller, S.
    Boga, E.
    Gehl, H. B.
    Seitz, D.
    Scholtz, L. U.
    Sudhoff, H.
    Todt, I.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2019, 39 (04) : 269 - 273