SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI

被引:0
|
作者
Mathieu, William [1 ]
Popovic, Milica [1 ]
Farivar, Reza [2 ]
机构
[1] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
[2] McGill Univ, Dept Ophthalmol, Montreal, PQ, Canada
来源
2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024 | 2024年
关键词
MRI; RF Coils; Phased Arrays; Flexible RF Coils;
D O I
10.1109/IMBIOC60287.2024.10590301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In head MRI applications, flexible RF receive-only head coils can offer improved SNR and patient comfort. In our work, we achieve partial, but sufficient, flexibility by decomposing an average head surface into movable, semi-flexible plates that comfortably adapt to the surface of the head. As a result, we can include a larger number of smaller elements, pushing the boundary of achievable SNR while still being able to resolve brain areas. In order to test the viability of the design, we investigate the SNR variability of two 12-channel frontal plate arrays when they are adapted to fit differently sized heads. The elements were constructed on a 3D-printed thermoplastic polyurethane (TPU) flexible substrate, with conductive loops on the inside surface to minimize their distance to the head. Experiments were conducted in an MRI scanner in which a spherical phantom was imaged by the frontal plate arrays together at four positions. We demonstrate that SNR decreases, as expected, as the gap between the plates increases, but in an acceptable range. The overall range of inter-plate distance results in SNR variability of approximately 15%. These results support the overall feasibility of the larger head coil composed of eight movable plates: the mechanical gaps that would appear for larger heads would not compromise the SNR and, therefore, signal integrity and would still outperform a similar fixed-size head coil.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 50 条
  • [21] White matter connectivity by diffusion distance on 3T MRI
    Sato, T
    Kashikura, K
    Kabasawa, H
    Yonekura, Y
    Minato, K
    IEEE EMBS APBME 2003, 2003, : 162 - 163
  • [22] Detection and grading of dAVF: prospects and limitations of 3T MRI
    Bink, Andrea
    Berkefeld, Joachim
    Wagner, Marlies
    You, Se-Jong
    Ackermann, Hanns
    Lorenz, Matthias W.
    Senft, Christian
    de Rochemont, Richard du Mesnil
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 429 - 438
  • [23] Detection and grading of dAVF: prospects and limitations of 3T MRI
    Andrea Bink
    Joachim Berkefeld
    Marlies Wagner
    Se-Jong You
    Hanns Ackermann
    Matthias W. Lorenz
    Christian Senft
    Richard du Mesnil de Rochemont
    European Radiology, 2012, 22 : 429 - 438
  • [24] Carotid MRI Detection of Intraplaque Hemorrhage at 3T and 1.5T
    McNally, J. Scott
    Yoon, Hyo-Chun
    Kim, Seong-Eun
    Narra, Krishna K.
    McLaughlin, Michael S.
    Parker, Dennis L.
    Treiman, Gerald S.
    JOURNAL OF NEUROIMAGING, 2015, 25 (03) : 390 - 396
  • [25] 'Black T2' at 3T MRI: a biomarker for disability in MS?
    Zhang, Y.
    Metz, L. M.
    Zabad, R. K.
    Mitchell, J. R.
    MULTIPLE SCLEROSIS, 2007, 13 (02): : 301 - 302
  • [26] Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T
    Prakkamakul, Supada
    Witzel, Thomas
    Huang, Susie
    Boulter, Daniel
    Borja, Maria J.
    Schaefer, Pamela
    Rosen, Bruce
    Heberlein, Keith
    Ratai, Eva
    Gonzalez, Gilberto
    Rapalino, Otto
    JOURNAL OF NEUROIMAGING, 2016, 26 (05) : 503 - 510
  • [27] Design and evaluation of a 1H/31P double-resonant helmet coil for 3T MRI of the brain
    Hong, Suk-Min
    Choi, Chang-Hoon
    Shah, N. Jon
    Felder, Joerg
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03)
  • [28] Detunable wireless ladder resonator inserts for enhanced SNR of local array coil at 1.5T MRI
    Lu, Ming
    Wang, Ruilin
    Chen, Yuanyuan
    Li, Rangsong
    Yang, Xiaoyue
    Liang, Hao
    Zhu, Haoqin
    Yan, Xinqiang
    MEDICAL PHYSICS, 2025,
  • [29] Prostate MR imaging at 3T with a longitudinal array endorectal surface coil and phased array body coil
    Kim, David Y.
    Schnall, Mitchell D.
    Rosen, Mark A.
    Connick, Thomas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1327 - 1330
  • [30] Multimodality approach in cryptogenic epilepsy with focus on morphometric 3T MRI
    Doelken, M. T.
    Mennecke, A.
    Huppertz, H. J.
    Rampp, S.
    Lukacs, E.
    Kasper, B. S.
    Kuwert, T.
    Ritt, P.
    Doerfler, A.
    Stefan, H.
    Hammen, T.
    JOURNAL OF NEURORADIOLOGY, 2012, 39 (02) : 87 - 96