SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI

被引:0
|
作者
Mathieu, William [1 ]
Popovic, Milica [1 ]
Farivar, Reza [2 ]
机构
[1] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
[2] McGill Univ, Dept Ophthalmol, Montreal, PQ, Canada
来源
2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024 | 2024年
关键词
MRI; RF Coils; Phased Arrays; Flexible RF Coils;
D O I
10.1109/IMBIOC60287.2024.10590301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In head MRI applications, flexible RF receive-only head coils can offer improved SNR and patient comfort. In our work, we achieve partial, but sufficient, flexibility by decomposing an average head surface into movable, semi-flexible plates that comfortably adapt to the surface of the head. As a result, we can include a larger number of smaller elements, pushing the boundary of achievable SNR while still being able to resolve brain areas. In order to test the viability of the design, we investigate the SNR variability of two 12-channel frontal plate arrays when they are adapted to fit differently sized heads. The elements were constructed on a 3D-printed thermoplastic polyurethane (TPU) flexible substrate, with conductive loops on the inside surface to minimize their distance to the head. Experiments were conducted in an MRI scanner in which a spherical phantom was imaged by the frontal plate arrays together at four positions. We demonstrate that SNR decreases, as expected, as the gap between the plates increases, but in an acceptable range. The overall range of inter-plate distance results in SNR variability of approximately 15%. These results support the overall feasibility of the larger head coil composed of eight movable plates: the mechanical gaps that would appear for larger heads would not compromise the SNR and, therefore, signal integrity and would still outperform a similar fixed-size head coil.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 50 条
  • [1] Conformal Occipital 18-Channel Receive-Only RF Coil for 3T MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 43 - 45
  • [2] Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T
    Reiss-Zimmermann, Martin
    Gutberlet, Marcel
    Koestler, Herbert
    Fritzsch, Dominik
    Hoffmann, Karl-Titus
    ACTA RADIOLOGICA, 2013, 54 (06) : 702 - 708
  • [3] Size-Adaptive Occipital 18-Channel Receive-Only RF Coil for 3T MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024,
  • [4] Impacts of RF Shimming on Local SAR Caused by MRI 3T Birdcage Coil near Femoral Plate Implants
    Zeng, Qi
    Guo, Ran
    Zheng, Jianfeng
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1005 - 1006
  • [5] Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T
    Muftuler, LT
    Gulsen, G
    Sezen, KD
    Nalcioglu, O
    JOURNAL OF MAGNETIC RESONANCE, 2002, 155 (01) : 39 - 44
  • [6] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    O'Donohoe, Rory L.
    Dunne, Ruth M.
    Kimbrell, Vera
    Tempany, Clare M.
    ABDOMINAL RADIOLOGY, 2019, 44 (03) : 1062 - 1069
  • [7] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    Rory L. O’Donohoe
    Ruth M. Dunne
    Vera Kimbrell
    Clare M. Tempany
    Abdominal Radiology, 2019, 44 : 1062 - 1069
  • [8] An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers
    Moody, Katherine Lynn
    Hollingsworth, Neal A.
    Zhao, Feng
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Wright, Steven M.
    McDougall, Mary Preston
    JOURNAL OF MAGNETIC RESONANCE, 2014, 246 : 62 - 68
  • [9] MRI compatibility study of an integrated PET/RF-coil prototype system at 3T
    Akram, Md Shahadat Hossain
    Obata, Takayuki
    Suga, Mikio
    Nishikido, Fumihiko
    Yoshida, Eiji
    Saito, Kazuyuki
    Yamaya, Taiga
    JOURNAL OF MAGNETIC RESONANCE, 2017, 283 : 62 - 70
  • [10] Numerical Design of RF Birdcage Coil without Lumped Elements for MRI 3T System
    Basari
    Priatna, Arwan
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 90 - 93