Sex differences in constructing dose-response calibration curves for micronuclei using cytokinesis-blocked micronucleus assay for radiation biological dosimetry in the Iranian population

被引:0
|
作者
Fardid, R. [1 ,2 ]
Aghazadeh, N. [1 ]
Parsaei, H. [3 ]
Mosleh-Shirazi, M. A. [2 ,4 ]
Zahraie, N. [1 ]
机构
[1] Shiraz Univ Med Sci, Sch Paramed Sci, Radiol Dept, Shiraz, Iran
[2] Shiraz Univ Med Sci, Ionizing & Nonionizing Radiat Protect Res Ctr, Sch Paramed Sci, Shiraz, Iran
[3] Shiraz Univ Med Sci, Sch Med, Dept Med Phys, Shiraz, Iran
[4] Shiraz Univ Med Sci, Dept Radiooncol, Phys Unit, Shiraz, Iran
关键词
Biodosimetry; Micronuclei; Dose-response curve; CBMN assay; Calibration curves; IONIZING-RADIATION; HUMAN-LYMPHOCYTES; CYTOGENETIC DAMAGE; SCORING CRITERIA; GAMMA-RAYS; X-RAYS; CHROMOSOME; TRIAGE; FREQUENCIES; INDUCTION;
D O I
10.1016/j.radmeas.2024.107281
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Biological dosimetry, using chromosome damage biomarkers, can be considered as a key measure for radiation overexposure assessment. Therefore, for accurate dose estimation through biodosimetry, it's imperative for each biological dosimetry laboratory to establish its own specific dose-response calibration curve. In this research, the cytokinesis-blocked micronucleus (CBMN) assay was utilized to determine the frequencies of micronuclei (MN) per binucleated cell in human peripheral blood lymphocytes exposed to x-ray radiation using a LINAC (6 MV) at doses up to 4 Gy. The aim was to establish an in vitro dose-response calibration curve in our laboratory for the Iranian demographic by analyzing blood samples of ten participants (5 males and 5 females) through CABAS and Dose Estimate software. Our findings indicate an over-dispersion of the Poisson distribution in the pooled data across both sexes, coupled with a linear-quadratic increase in MN yield with dose which was particularly pronounced in the female group. The constructed dose-response curves for micronuclei yield are represented by equations Y= (0.0102 +/- 0.0016) +(0.0296 +/- 0.0054) D+(0.0232 +/- 0.0017) D2 and Y= (0.0084 +/- 0.0010) +(0.0212 +/- 0.0034) D+(0.0160 +/- 0.0011) D2 for the female groups, respectively. The alpha and beta coefficients, derived from the Dose Estimate software for each male and female group, were closely comparable with those obtained from the CABAS program and previous studies. The analysis of statistical parameters such as the Weighted Chi Squared (chi 2) and p-value suggests that using distinct curves for each sex, rather than a unified biodosimetry formula for pooled data, ensures more accurate radiation dose estimates. Consequently, the findings of this study provide us with the assurance to utilize the derived calibration curve of MN for upcoming biological dosimetry needs in Iran. However, to enhance the reliability of results, it's essential to use biodosimetry with diverse assays and consider all clinical and physical parameters, given the limitations of cytogenetic assays.
引用
收藏
页数:9
相关论文
共 4 条
  • [1] The cytokinesis-blocked micronucleus assay: dose-response calibration curve, background frequency in the population and dose estimation
    Rastkhah, E.
    Zakeri, F.
    Ghoranneviss, M.
    Rajabpour, M. R.
    Farshidpour, M. R.
    Mianji, F.
    Bayat, M.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2016, 55 (01) : 41 - 51
  • [2] The cytokinesis-blocked micronucleus assay: dose–response calibration curve, background frequency in the population and dose estimation
    E. Rastkhah
    F. Zakeri
    M. Ghoranneviss
    M. R. Rajabpour
    M. R. Farshidpour
    F. Mianji
    M. Bayat
    Radiation and Environmental Biophysics, 2016, 55 : 41 - 51
  • [3] The cytokinesis-blocked micronucleus assay: Dose estimation and inter-individual differences in the response to γ-radiation
    Antunes, A. C.
    Martins, V.
    Cardoso, J.
    Santos, L.
    Gil, O. Monteiro
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2014, 760 : 17 - 22
  • [4] BIOLOGICAL DOSIMETRY USING THE MICRONUCLEUS ASSAY FOR LYMPHOCYTES - INTERINDIVIDUAL DIFFERENCES IN DOSE-RESPONSE
    THIERENS, H
    VRAL, A
    DERIDDER, L
    HEALTH PHYSICS, 1991, 61 (05): : 623 - 630