Atrioventricular Synchrony Delivered by a Dual-Chamber Leadless Pacemaker System

被引:4
|
作者
Ip, James E. [1 ]
Rashtian, Mayer [2 ]
Exner, Derek V. [3 ]
Reddy, Vivek Y. [4 ]
Doshi, Rahul [5 ]
Badie, Nima [6 ]
Nevo, Jordan R. [6 ]
Goil, Aditya [6 ]
Defaye, Pascal [7 ]
Canby, Robert [8 ]
Bongiorni, Maria Grazia [9 ]
Shoda, Morio [10 ]
Hindricks, Gerhard [11 ]
Knops, Reinoud E. [12 ]
机构
[1] Weill Cornell Med, New York Presbyterian, New York, NY USA
[2] Huntington Mem Hosp, Pasadena, CA USA
[3] Foothills Med Ctr, Calgary, AB, Canada
[4] Icahn Sch Med Mt Sinai, New York, NY USA
[5] HonorHlth Cardiac Arrhythmia Grp, Scottsdale, AZ USA
[6] Abbott, Sylmar, CA USA
[7] CHRU Albert Michallon, Grenoble, France
[8] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[9] San Rossore Private Hosp & Med Ctr, Pisa, Italy
[10] Tokyo Womens Med Univ, Tokyo, Japan
[11] Heart Ctr Leipzig GmbH, Leipzig, Germany
[12] Amsterdam UMC, Amsterdam, Netherlands
关键词
pacemaker; artificial; COMPLICATIONS; THERAPY;
D O I
10.1161/CIRCULATIONAHA.124.069006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND:A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS:A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS:In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS:This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 50 条
  • [31] Micra-AV leadless pacemaker and atrioventricular (dys)synchrony: A stepwise process
    Mitacchione, Gianfranco
    Schiavone, Marco
    Gasperetti, Alessio
    Ruggiero, Diego
    Denora, Marialessia
    Viecca, Maurizio
    Forleo, Giovanni Battista
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (10): : 1738 - 1742
  • [32] MODIFIED TECHNIQUE FOR DUAL-CHAMBER PACEMAKER INSERTION
    GUIDERA, PM
    HOWARD, WHB
    SUTTON, FJ
    SAGER, GL
    SURGERY GYNECOLOGY & OBSTETRICS, 1993, 176 (06): : 603 - 604
  • [33] Possible Device Malfunction in a Dual-Chamber Pacemaker
    Hornberger, Jared W.
    Fentanes, Emilio
    Gerasimon, Gregg G.
    JAMA INTERNAL MEDICINE, 2017, 177 (09) : 1371 - 1372
  • [34] Short atrioventricular delay reduces the degree of mitral regurgitation in patients with a sequential dual-chamber pacemaker
    Rossi, R
    Muia, N
    Turco, V
    Sgura, FA
    Molinari, R
    Modena, MG
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (07): : 901 - 905
  • [35] OUTCOME OF DUAL-CHAMBER PACING FOR THE PACEMAKER SYNDROME
    NISHIMURA, RA
    GERSH, BJ
    HOLMES, DR
    VLIETSTRA, RE
    BROADBENT, JC
    MAYO CLINIC PROCEEDINGS, 1983, 58 (07) : 452 - 456
  • [36] Conductive Impulse for Wireless Communication in Dual-Chamber Leadless Pacemakers
    Khaleghi, Ali
    Noormohammadi, Reza
    Balasingham, Ilangko
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (01) : 443 - 451
  • [37] FDA approves first leadless dual-chamber pacing system; A breakthrough in therapy of bradycardia
    Ali, Eman
    INTERNATIONAL JOURNAL OF SURGERY OPEN, 2023, 58
  • [38] OUTCOME OF USING DUAL-CHAMBER PACING FOR THE PACEMAKER SYNDROME
    NISHIMURA, RA
    GERSH, BJ
    HOLMES, DR
    VLIETSTRA, RE
    BROADBENT, JC
    CLINICAL RESEARCH, 1983, 31 (02): : A209 - A209
  • [39] DUAL-CHAMBER PACEMAKER THERAPY IN OBSTRUCTIVE HYPERTROPHIC CARDIOMYOPATHY
    SADOUL, N
    SIMON, JP
    DECHILLOU, C
    DODINOT, B
    ALIOT, E
    SLADE, AKB
    SAUMAREZ, RC
    PRASAD, K
    CAMM, AJ
    CIRCULATION, 1995, 92 (04) : 1062 - 1063
  • [40] ARRHYTHMIAS AFTER ATRIAL AND DUAL-CHAMBER PACEMAKER IMPLANTATIONS
    JORDAENS, L
    ROBBENS, E
    VANWASSENHOVE, E
    CLEMENT, DL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 693 - 693