Atrioventricular Synchrony Delivered by a Dual-Chamber Leadless Pacemaker System

被引:4
|
作者
Ip, James E. [1 ]
Rashtian, Mayer [2 ]
Exner, Derek V. [3 ]
Reddy, Vivek Y. [4 ]
Doshi, Rahul [5 ]
Badie, Nima [6 ]
Nevo, Jordan R. [6 ]
Goil, Aditya [6 ]
Defaye, Pascal [7 ]
Canby, Robert [8 ]
Bongiorni, Maria Grazia [9 ]
Shoda, Morio [10 ]
Hindricks, Gerhard [11 ]
Knops, Reinoud E. [12 ]
机构
[1] Weill Cornell Med, New York Presbyterian, New York, NY USA
[2] Huntington Mem Hosp, Pasadena, CA USA
[3] Foothills Med Ctr, Calgary, AB, Canada
[4] Icahn Sch Med Mt Sinai, New York, NY USA
[5] HonorHlth Cardiac Arrhythmia Grp, Scottsdale, AZ USA
[6] Abbott, Sylmar, CA USA
[7] CHRU Albert Michallon, Grenoble, France
[8] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[9] San Rossore Private Hosp & Med Ctr, Pisa, Italy
[10] Tokyo Womens Med Univ, Tokyo, Japan
[11] Heart Ctr Leipzig GmbH, Leipzig, Germany
[12] Amsterdam UMC, Amsterdam, Netherlands
关键词
pacemaker; artificial; COMPLICATIONS; THERAPY;
D O I
10.1161/CIRCULATIONAHA.124.069006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND:A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS:A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS:In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS:This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 50 条
  • [1] A Dual-Chamber Leadless Pacemaker
    Knops, Reinoud E.
    Reddy, Vivek Y.
    Ip, James E.
    Doshi, Rahul
    Exner, Derek V.
    Defaye, Pascal
    Canby, Robert
    Bongiorni, Maria Grazia
    Shoda, Morio
    Hindricks, Gerhard
    Neuzil, Petr
    Rashtian, Mayer
    Breeman, Karel T. N.
    Nevo, Jordan R.
    Ganz, Leonard
    Hubbard, Chris
    Cantillon, Daniel J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 388 (25): : 2360 - 2370
  • [2] A Dual-Chamber Leadless Pacemaker
    Ganz, Leonard
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 389 (11): : 1055 - 1057
  • [3] Dual-chamber leadless pacing: Atrioventricular synchrony in preclinical models of normal or blocked atrioventricular conduction
    Reddy, Vivek Y.
    Neuzil, Petr
    Booth, Daniel F.
    Knops, Reinoud E.
    Doshi, Rahul N.
    Rashtian, Mayer
    V. Exner, Derek
    Banker, Rajesh S.
    Nair, Devi
    Hadadi, Cyrus A.
    Badie, Nima
    Yang, Weiqun
    Ligon, David
    Ip, James E.
    HEART RHYTHM, 2023, 20 (08) : 1146 - 1155
  • [4] Postmortem examination of a dual-chamber leadless pacemaker system: Implications for chronic atrial leadless pacemaker removal
    Ip, James E.
    HEART RHYTHM, 2024, 21 (04) : 488 - 489
  • [5] Wireless Communication Between Paired Leadless Pacemakers for Dual-Chamber Synchrony
    Cantillon, Daniel J.
    Gambhir, Alok
    Banker, Rajesh
    Rashtian, Mayer
    Doshi, Rahul
    Badie, Nima
    Booth, Daniel
    Yang, Weiqun
    Nee, Peter
    Fishler, Matthew
    Ligon, David
    Neuzil, Petr
    Knops, Reinoud E.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (07): : 456 - 463
  • [6] Implantation techniques for a helix-fixation dual-chamber leadless pacemaker
    Neuzil, Petr
    Hubbard, Chris
    Doshi, Rahul N.
    Reddy, Vivek Y.
    Canby, Robert
    Defaye, Pascal
    V. Exner, Derek
    Shoda, Morio
    Bongiorni, Maria Grazia
    Hindricks, Gerhard
    Callahan, Thomas
    Sundaram, Sri
    Bruhns, Kenneth P.
    Booth, Daniel F.
    Knops, Reinoud E.
    Ip, James E.
    HEART RHYTHM, 2024, 21 (12) : 2552 - 2562
  • [7] Transcatheter leadless pacemaker implantation in a patient with a transvenous dual-chamber pacemaker already in place
    Karjalainen, Pasi P.
    Nammas, Wail
    Paana, Tuomas
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (04) : 554 - 556
  • [8] Erosion of a Dual-Chamber Pacemaker System
    Kypta, Alexander
    Blessberger, Hermann
    Kammler, Juergen
    Lambert, Thomas
    Steinwender, Clemens
    JOURNAL OF CARDIAC SURGERY, 2015, 30 (02) : 217 - 217
  • [9] Chronic wireless communication between dual-chamber leadless pacemaker devices
    Doshi, Rahul N.
    Ip, James E.
    Defaye, Pascal
    V. Exner, Derek
    Reddy, Vivek Y.
    Hindricks, Gerhard
    Canby, Robert
    Shoda, Morio
    Bongiorni, Maria G.
    Neuzl, Petr
    Callahan, Thomas
    Badie, Nima
    Ligon, David
    Knops, Reinoud E.
    HEART RHYTHM, 2025, 22 (04) : 1010 - 1020
  • [10] Two Is Better than One: Aveir DR Leadless Pacemaker System with Dual-Chamber Pacing
    Tang, Jonathan E.
    Guirguis, Fady
    Holloway, Jordan O.
    Wernke, Cassidy
    Reeves, Jeremy
    Kumar, Nicolas A.
    Savona, Salvatore J.
    Essandoh, Michael K.
    Iyer, Manoj H.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2025, 39 (01) : 286 - 291