A Cross-Sectional Validation of Horos and CoreSlicer Software Programs for Body Composition Analysis in Abdominal Computed Tomography Scans in Colorectal Cancer Patients

被引:0
|
作者
Jimenez-Sanchez, Andres [1 ]
Soriano-Redondo, Maria Elisa [2 ]
Pereira-Cunill, Jose Luis [1 ]
Martinez-Ortega, Antonio Jesus [1 ]
Rodriguez-Mowbray, Jose Ramon [3 ]
Ramallo-Solis, Irene Maria [4 ]
Garcia-Luna, Pedro Pablo [1 ]
机构
[1] Univ Seville, IBiS Hosp Univ Virgen Rocio, Unidad Gest Clin Endocrinol & Nutr, Inst Biomed Sevilla,CSIC, Avda Manuel Siurot s-n, Seville 41013, Spain
[2] Hosp Univ Virgen Rocio, Unidad Gest Clin Radiodiagnost, Avda Manuel Siurot s-n, Seville 41013, Spain
[3] Hosp Univ Virgen Rocio, Unidad Gest Clin Oncol Med, Avda Manuel Siurot s-n, Seville 41013, Spain
[4] Hosp Univ Virgen Rocio, Unidad Gest Clin Cirugia Gen & Aparato Digest, Avda Manuel Siurot s-n, Seville 41013, Spain
关键词
Alberta protocol; Horos; CoreSlicer; computed tomography; body composition; muscle mass; colorectal cancer; sarcopenia; SKELETAL-MUSCLE MASS; SARCOPENIA; MORTALITY;
D O I
10.3390/diagnostics14151696
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Body composition assessment using computed tomography (CT) scans may be hampered by software costs. To facilitate its implementation in resource-limited settings, two open-source segmentation programs (Horos and CoreSlicer) were transversally validated in colorectal cancer patients. Methods: Contrast-enhanced abdominal CT scans were analyzed following the Alberta protocol. The Cross-Sectional Area (CSA) and intensities of skeletal muscle tissue (MT), subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), and intramuscular adipose tissue (IMAT) were measured. The Skeletal Muscle Index (SMI) was calculated. Cutoff points were applied to the SMI, MT intensity, and VAT CSA to define muscle atrophy, myosteatosis, and abdominal obesity. The inter-software agreement was evaluated using different statistical tools. Results: A total of 68 participants were measured. The MT CSA and SMI displayed no differences. The MT CSA agreement was excellent, and both programs provided equal muscle atrophy prevalences. CoreSlicer underestimated the MT intensity, with a non-significant myosteatosis prevalence increase (+5.88% and +8.82%) using two different operative definitions. CoreSlicer overestimated the CSA and intensity in both VAT and SAT, with a non-significant increase (+2.94%) in the abdominal obesity prevalence. Conclusions: Both software programs were feasible tools in the study group. The MT CSA showed great inter-software agreement and no muscle atrophy misdiagnosis. Segmentation differences in the MT intensity and VAT CSA caused limited diagnostic misclassification in the study sample.
引用
收藏
页数:17
相关论文
共 44 条
  • [41] Changes in cross-sectional area of pulmonary vessels on chest computed tomography after chemotherapy in patients with advanced non-squamous non-small-cell lung cancer
    Karayama, Masato
    Inui, Naoki
    Kusagaya, Hideki
    Suzuki, Seiichiro
    Inoue, Yusuke
    Enomoto, Noriyuki
    Fujisawa, Tomoyuki
    Nakamura, Yutaro
    Suda, Takafumi
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2016, 77 (05) : 1011 - 1018
  • [42] Assessment of Calcium Score Cutoff Point for Clinically Significant Aortic Stenosis on Lung Cancer Screening Program Low-Dose Computed Tomography-A Cross-Sectional Analysis
    Klein-Awerjanow, Kaja
    Rzyman, Witold
    Dziedzic, Robert
    Fijalkowska, Jadwiga
    Spychalski, Piotr
    Szurowska, Edyta
    Fijalkowski, Marcin
    DIAGNOSTICS, 2023, 13 (02)
  • [43] Development of a nomogram based on body composition analysis of quantitative computed tomography combined with clinical prognostic factors to predict disease-free survival after surgery and adjuvant chemotherapy in patients with gastric cancer
    Wei, Longyu
    Fu, Baoyue
    Bo, Juan
    Jia, Haodong
    Sun, Mingjie
    Jiang, Xueyan
    Wang, Tingting
    Wang, Peipei
    Dong, Jiangning
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 8489 - 8503
  • [44] Detection of alteration in carotid artery volumetry using standard-of-care computed tomography surveillance scans following unilateral radiation therapy for early-stage tonsillar squamous cell carcinoma survivors: a cross-sectional internally-matched carotid isodose analysis
    Koutroumpakis, Efstratios
    Naser, Mohamed A.
    Mohamed, Abdallah Sherif Radwan
    Eraj, Salman A.
    Jarre, Andrea
    Shiao, Jay C.
    Kamal, Mona
    Perni, Subha
    Phan, Jack P.
    Morrison, William H.
    Frank, Steven J.
    Gunn, G. Brandon
    Garden, Adam S.
    Deswal, Anita
    Abe, Jun-ichi
    Rosenthal, David I.
    Mouhayar, Elie
    Fuller, Clifton D.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2025, 51