Explore the feasibility of using spot-scanning proton arc therapy for a synchrotron accelerator-based proton therapy system - A simulation study

被引:0
|
作者
Cong, Xiaoda [1 ]
Liu, Gang [2 ]
Liu, Peilin [1 ]
Zhao, Lewei [3 ]
Chen, Shupeng [1 ]
Li, Xiaoqiang [1 ]
Shen, Jiajian [4 ]
Ding, Xuanfeng [1 ]
机构
[1] Corewell Hlth William Beaumont Univ Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
[2] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Canc Ctr, Wuhan, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA USA
[4] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ 85054 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2025年 / 26卷 / 01期
关键词
intensity-modulated proton therapy; spot scanning proton arc therapy; synchrotron-accelerator; DELIVERY-EFFICIENT; SPARC THERAPY; BEAM; ROBUST;
D O I
10.1002/acm2.14526
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the feasibility and plan quality of spot-scanning proton arc therapy (SPArc) using a synchrotron-accelerator- based proton therapy system compared to intensity-modulated proton therapy (IMPT). Approach: Five representative disease sites, including head and neck, lung, liver, brain chordoma, and prostate cancers, were retrospectively selected. Both IMPT and SPArc plans are generated with the HITACHI ProBEAT PBS system's minimum MU constraints and physics beam model. The SPArc plans are generated with 2.5 degrees degrees sampling frequency. The static delivery time was simulated based on the previously published synchrotron delivery sequence model, and the dynamic delivery time was simulated using a proton arc gantry mechanical model integrated with the synchrotron delivery sequence. Both dosimetric plan quality and delivery efficiency are evaluated. Main results: A superior plan quality is reached compared with the IMPT plans generated for the same disease site. However, a relatively prolonged static and dynamic delivery time post new challenge, as static time increased by 49.22% and dynamic time 59.10% on average. Significance: This study presents the first simulation results of delivering the SPArc plans using a synchrotron-accelerated proton therapy system. The result shows its feasibility and limitations, which could guide future development.
引用
收藏
页数:10
相关论文
共 42 条
  • [41] Small-spot intensity-modulated proton therapy and volumetric-modulated arc therapies for patients with locally advanced non-small-cell lung cancer: A dosimetric comparative study
    Liu, Chenbin
    Sio, Terence T.
    Deng, Wei
    Shan, Jie
    Daniels, Thomas B.
    Rule, William G.
    Lara, Pedro R.
    Korte, Shawn M.
    Shen, Jiajian
    Ding, Xiaoning
    Schild, Steven E.
    Bues, Martin
    Liu, Wei
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 140 - 148
  • [42] Accelerator-based boron neutron capture therapy for malignant glioma: a pilot neutron irradiation study using boron phenylalanine, sodium borocaptate and liposomal borocaptate with a heterotopic U87 glioblastoma model in SCID mice
    Zavjalov, Evgenii
    Zaboronok, Alexander
    Kanygin, Vladimir
    Kasatova, Anna
    Kichigin, Aleksandr
    Mukhamadiyarov, Rinat
    Razumov, Ivan
    Sycheva, Tatiana
    Mathis, Bryan J.
    Maezono, Sakura Eri B.
    Matsumura, Akira
    Taskaev, Sergey
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2020, 96 (07) : 868 - 878