Effectiveness of Blood Glucose Time in Range to Reduce Risk of Blood Glucose Extrusion and Improve Blood Glucose Metrics in Type 1 Diabetic Patients

被引:0
|
作者
Oraibi, Omar [1 ]
Somaili, Mohammed [1 ]
Elmakki, Erwa [1 ]
Alqassimi, Sameer [1 ]
Madkhali, Mohammed Ali [1 ]
Mohrag, Mostafa [1 ]
Abusageah, Faisal [1 ]
Alhazmi, Mohammed [1 ]
Alfaifi, Samar [1 ]
Ageeli, Ruba [1 ]
Sumayli, Mohammed [1 ]
Arishi, Fatimah [1 ]
Alhazmi, Abdulaziz H. [2 ]
Hummadi, Abdulrahman [3 ]
机构
[1] Jazan Univ, Fac Med, Internal Med Dept, Jazan, Saudi Arabia
[2] Jazan Univ, Fac Med, Microbiol Dept, Jazan, Saudi Arabia
[3] Minist Hlth, Endocrine & Diabetic Ctr, Jazan, Saudi Arabia
关键词
Diabetes mellitus; CGM; A1C; glucose management indicator; hypoglycemia; hyperglycemia; GLYCEMIC CONTROL; COMPLICATIONS; PREVALENCE; THERAPY;
D O I
10.2174/0118715303263019231029163336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background With evolving diabetes technology, continuous glucose monitoring (CGM) and time in range have been advanced as critical measurements to assess complications. They have shown improvement in A1C levels and decreased episodes of blood glucose extrusion.Aims This study aimed to assess the awareness and utilization of blood glucose time in range and its effectiveness in reducing the risk of blood glucose extrusion and improving blood glucose metrics among patients with type 1 diabetes mellitus.Methods A retrospective study included 342 patients who met the inclusion criteria and were using the CGM, aiming for a TIR of 70% daily. Glycemic control was followed using TIR data, blood glucose extrusion frequency (including hyperglycemia and hypoglycemia events), active sensor time, average blood glucose, and glucose management indicator (GMI) levels.Results A total of 342 individuals participated in this study, the majority of whom were below 18 years of age (62.3%). The hypoglycemic frequency was significantly increased compared to the baseline, and most participants experienced hypoglycemia events (p = 0.0001). The incidences increased over time, with 90.9% and 93% having hypoglycemia at 60 and 90 days (p = 0.0001), respectively. The active scan and sensor time were not followed, which led to the blood glucose target not being achieved, with no improvement throughout the study. Consequently, no improvement occurred in glycemic control.Conclusion CGM technology has been promising and proven effective in improving glycemic. However, our study did not show these benefits as expected, which could be explained by the underutilization and improper use of the CGM.
引用
收藏
页码:1197 / 1203
页数:7
相关论文
共 50 条
  • [41] Time in range: a new parameter to evaluate blood glucose control in patients with diabetes
    Monica Andrade Lima Gabbay
    Melanie Rodacki
    Luis Eduardo Calliari
    Andre Gustavo Daher Vianna
    Marcio Krakauer
    Mauro Scharf Pinto
    Janice Sepúlveda Reis
    Marcia Puñales
    Leonardo Garcia Miranda
    Ana Claudia Ramalho
    Denise Reis Franco
    Hermelinda Pedrosa Cordeiro Pedrosa
    Diabetology & Metabolic Syndrome, 12
  • [43] Time in range: a new parameter to evaluate blood glucose control in patients with diabetes
    Gabbay, Monica Andrade Lima
    Rodacki, Melanie
    Calliari, Luis Eduardo
    Vianna, Andre Gustavo Daher
    Krakauer, Marcio
    Pinto, Mauro Scharf
    Reis, Janice Sepulveda
    Punales, Marcia
    Miranda, Leonardo Garcia
    Ramalho, Ana Claudia
    Franco, Denise Reis
    Pedrosa, Hermelinda Pedrosa Cordeiro
    DIABETOLOGY & METABOLIC SYNDROME, 2020, 12 (01):
  • [44] UTILITY OF BLOOD GLUCOSE METERS CALCULATING INSULIN DOSE IN THE MANAGEMENT OF TYPE 1 DIABETIC PATIENTS
    Maraver-Selfa, S.
    Munoz-Garach, A.
    Garcia-Aleman, J.
    Pinzon-Martin, J.
    Cornejo-Pareja, I.
    Tinahones-Madueno, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A117 - A118
  • [45] USE OF MICROCIDE (GLUCOSE OXIDASE) FOR GLUCOSE ASSAY IN NORMAL AND DIABETIC BLOOD
    LUKOMSKAIA, IS
    GORODEZKY, VK
    BIOKHIMIYA, 1961, 26 (03): : 477 - &
  • [46] Blood glucose concentration control for type 1 diabetic patients: a multiple-model strategy
    Batmani, Yazdan
    Khodakaramzadeh, Shadi
    IET SYSTEMS BIOLOGY, 2020, 14 (01) : 24 - 30
  • [47] The effect of the insulin analog lispro on nighttime blood glucose control in type 1 diabetic patients
    Ahmed, ABE
    Home, PD
    DIABETES CARE, 1998, 21 (01) : 32 - 37
  • [48] Higher Order Sliding Mode Control for Blood Glucose Regulation of Type 1 Diabetic Patients
    Djouima, Mounir
    Azar, Ahmad Taher
    Drid, Said
    Mehdi, Driss
    INTERNATIONAL JOURNAL OF SYSTEM DYNAMICS APPLICATIONS, 2018, 7 (01) : 65 - 84
  • [49] What is the Optimal Blood Glucose Range to Improve Morbidity and Mortality in Surgical Patients? Reply
    Jeschke, Marc G.
    ANNALS OF SURGERY, 2011, 254 (04) : 672 - 673
  • [50] Alteration of insulin secretion and blood glucose course under glibenclamide by acarbose in type 2 diabetic patients: Additive blood glucose-lowering effect and reduced risk for hypoglycemia
    Rosak, C
    Haupt, E
    Walter, T
    Werner, J
    DIABETES, 2000, 49 : A348 - A348