Effectiveness of Blood Glucose Time in Range to Reduce Risk of Blood Glucose Extrusion and Improve Blood Glucose Metrics in Type 1 Diabetic Patients

被引:0
|
作者
Oraibi, Omar [1 ]
Somaili, Mohammed [1 ]
Elmakki, Erwa [1 ]
Alqassimi, Sameer [1 ]
Madkhali, Mohammed Ali [1 ]
Mohrag, Mostafa [1 ]
Abusageah, Faisal [1 ]
Alhazmi, Mohammed [1 ]
Alfaifi, Samar [1 ]
Ageeli, Ruba [1 ]
Sumayli, Mohammed [1 ]
Arishi, Fatimah [1 ]
Alhazmi, Abdulaziz H. [2 ]
Hummadi, Abdulrahman [3 ]
机构
[1] Jazan Univ, Fac Med, Internal Med Dept, Jazan, Saudi Arabia
[2] Jazan Univ, Fac Med, Microbiol Dept, Jazan, Saudi Arabia
[3] Minist Hlth, Endocrine & Diabetic Ctr, Jazan, Saudi Arabia
关键词
Diabetes mellitus; CGM; A1C; glucose management indicator; hypoglycemia; hyperglycemia; GLYCEMIC CONTROL; COMPLICATIONS; PREVALENCE; THERAPY;
D O I
10.2174/0118715303263019231029163336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background With evolving diabetes technology, continuous glucose monitoring (CGM) and time in range have been advanced as critical measurements to assess complications. They have shown improvement in A1C levels and decreased episodes of blood glucose extrusion.Aims This study aimed to assess the awareness and utilization of blood glucose time in range and its effectiveness in reducing the risk of blood glucose extrusion and improving blood glucose metrics among patients with type 1 diabetes mellitus.Methods A retrospective study included 342 patients who met the inclusion criteria and were using the CGM, aiming for a TIR of 70% daily. Glycemic control was followed using TIR data, blood glucose extrusion frequency (including hyperglycemia and hypoglycemia events), active sensor time, average blood glucose, and glucose management indicator (GMI) levels.Results A total of 342 individuals participated in this study, the majority of whom were below 18 years of age (62.3%). The hypoglycemic frequency was significantly increased compared to the baseline, and most participants experienced hypoglycemia events (p = 0.0001). The incidences increased over time, with 90.9% and 93% having hypoglycemia at 60 and 90 days (p = 0.0001), respectively. The active scan and sensor time were not followed, which led to the blood glucose target not being achieved, with no improvement throughout the study. Consequently, no improvement occurred in glycemic control.Conclusion CGM technology has been promising and proven effective in improving glycemic. However, our study did not show these benefits as expected, which could be explained by the underutilization and improper use of the CGM.
引用
收藏
页码:1197 / 1203
页数:7
相关论文
共 50 条
  • [21] Distribution of Blood Glucose and the Correlation between Blood Glucose and Hemoglobin A1c Levels in Diabetic Outpatients
    Yamamoto-Honda, Ritsuko
    Kitazato, Hiroji
    Hashimoto, Shinji
    Takahashi, Yoshihiko
    Yoshida, Yoko
    Hasegawa, Chiyoko
    Akanuma, Yasuo
    Noda, Mitsuhiko
    ENDOCRINE JOURNAL, 2008, 55 (05) : 913 - 923
  • [22] Self monitoring of blood glucose in blind diabetic patients
    Windecker, R
    Heinemann, L
    Sawicki, PT
    DIABETIC MEDICINE, 1997, 14 (08) : 703 - 706
  • [23] An approach to control the blood glucose level in diabetic patients
    Ionescu, C.
    Zlate, S.
    De Keyser, R.
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 1, PROCEEDINGS, 2006, : 48 - +
  • [24] Updates on the self monitoring of blood glucose in diabetic patients
    Lippi, Giuseppe
    Montagnana, Martina
    BIOCHIMICA CLINICA, 2006, 30 (5-6) : 482 - 486
  • [25] Type-1 Fuzzy Controller for Blood Glucose Regulation in Type-1 Diabetic Patients
    Thakur, Priyanka
    Pillay, Yrithu T.
    Watkins, John
    Sawan, Edwin
    SOUTHEASTCON 2024, 2024, : 1205 - 1209
  • [26] BLOOD GLUCOSE MONITORING SYSTEMS' PERFORMANCE IN LOW BLOOD GLUCOSE RANGE AND ITS CLINICAL IMPLICATIONS
    Shaginian, R.
    Richardson, J.
    Pardo, S.
    Stuhr, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A142 - A142
  • [27] Effect of Blood Glucose Excursions on the Risk of Diabetic Retinopathy in Type 2 Diabetes
    Liu, Yu
    He, Yangfang
    DIABETES, 2011, 60 : A570 - A570
  • [28] GINGIVAL CREVICULAR BLOOD FOR ASSESSMENT OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS
    PARKER, RC
    RAPLEY, JW
    ISLEY, W
    SPENCER, P
    KILLOY, WJ
    JOURNAL OF PERIODONTOLOGY, 1993, 64 (07) : 666 - 672
  • [29] Comparison of Glucose Metrics by Capillary Blood Glucose and Continuous Glucose Monitoring among People with Type 2 Diabetes on Hemodialysis
    Galindo, Rodolfo J.
    Gerges, Amany Y. G.
    Moazzami, Bobak
    Peng, Limin
    Tuttle, Katherine R.
    Umpierrez, Guillermo
    DIABETES, 2023, 72
  • [30] Reduction of blood glucose variability in type 1 diabetic patients treated by pancreatic islet transplantation - Interest of continuous glucose monitoring
    Kessler, L
    Passemard, R
    Oberholzer, J
    Benhamou, PY
    Bucher, P
    Toso, C
    Meyer, P
    Penfornis, A
    Badet, L
    Wolf, P
    Colin, C
    Morel, P
    Pinget, M
    DIABETES CARE, 2002, 25 (12) : 2256 - 2262