Investigations of the UVC 222 NM air cleaning system in an air-conditioned room

被引:4
作者
Leow, Chee Huan [1 ]
Saw, Lip Huat [1 ]
Low, Foon Siang [1 ]
机构
[1] Univ Tunku Abdul Rahman, Lee Kong Chian Fac Engn & Sci, Kajang 43000, Selangor, Malaysia
关键词
UVGI; Disinfection; Airborne transmission; Indoor air quality;
D O I
10.1016/j.buildenv.2024.111990
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Far-Ultraviolet-C (far-UVC) 222 nm was introduced during the Covid-19 pandemic to disinfect the airborne pathogens, particularly SARS-CoV-2. Although far-UVC 222 nm has shown promising results in surface disinfection, its efficacy in air disinfection remains uncertain due to additional variables in air. This study investigated the efficacy of far-UVC 222 nm UVGI in air disinfection experimentally, using total plate count, and input the measured far-UVC intensity into the computational fluid dynamic model to predict infection risk using the Wells- Riley model. Experimental results indicated that after 1 h of far-UVC irradiation, an equivalent far-UVC dosage of 21.31 J/m2, 2 , airborne bacteria concentration was reduced by 44.4 %-74.1 %, while airborne fungal concentration showed a marginal reduction. In a recirculating air-conditioned room, a 20 W far-UVC fixture installation, referred to as Case 1, demonstrated the highest available dosage of 7.66 % difference compared to Case 2. The use of far-UVC in Case 1 can reduce the risk of infection for the influenza H1N1, SARS-CoV-2, and Mycobacterium tuberculosis by 54.48 %, 60.06 %, and 83.73 %, respectively. The study suggests installing far-UVC near the recirculating air-conditioner supply air jet and away from surrounding walls for optimum effectiveness. These results provide recommendations for alternatives to upper-room UVGI, offering a viable option for continuous room air and surface disinfection.
引用
收藏
页数:10
相关论文
共 50 条
[1]  
AIHA, 2005, Field Guide for the Determination of Biological Contaminants inEnvironmental Samples, Vsecond
[2]  
[Anonymous], 2004, ICNIRP Guidelines, On Limites of Exposure to Ultraviolet Radiation of Wavelengths Between 180 nm and 400 nm (Incoherent Optical Radiation)
[3]  
ASHRAE, 2021, ASHRAE Handbook- Fundamental
[4]  
ASHRAE, 2010, Indoor Air Quality Guide
[5]  
ASHRAE, 2022, ASHRAE Position Document on Building Decarbonization
[6]  
ASHRAE, 2020, HVAC SYSTEMS EQUIPME
[7]  
ASHRAE, 2022, Building readiness
[8]  
ASHRAE, 2019, ASHRAE HandbookHVAC ApplicationsSI Edition, p25.1
[9]  
Beggs C.B., 2010, Potential for airborne transmission of infection in the waiting areas of healthcare premises: stochastic analysis using a Monte Carlo model
[10]   Far-UVC light (222 nm) efficiently and safely inactivates airborne human coronaviruses [J].
Buonanno, Manuela ;
Welch, David ;
Shuryak, Igor ;
Brenner, David J. .
SCIENTIFIC REPORTS, 2020, 10 (01)