Comparability of Beckman Coulter Cardiac Troponin I Assays

被引:0
|
作者
Stanek, Caroline G. [1 ]
Lima, Jose [1 ]
Cao, Liyun [1 ]
机构
[1] Univ Alabama Birmingham, Dept Pathol, WP230H,619 South 19th St, Birmingham, AL 35249 USA
来源
ANNALS OF CLINICAL AND LABORATORY SCIENCE | 2024年 / 54卷 / 03期
关键词
HIGH-SENSITIVITY TROPONIN; SURGERY; IMPACT;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective. . Cardiac troponin I (cTnI) is one of the most sensitive and specific fi c biomarkers of myocardial injury. Th e rise and/or fall of cardiac troponins above the 99th percentile of the upper reference limit (URL) is required in the assessment of acute myocardial infarction. Methods. . We analyzed the variation between the Beckman Coulter contemporary cTnI AccuTnI+3 assay and high sensitivity cTnI (hs-cTnI) assay tested on DXI 800 using 424 patient specimens with troponin levels ranging from 0-16754 ng/L. We also analyzed the concordance of the same assay hs-cTnI on different ff erent Beckman Coulter instruments Access 2 and DXI 800 using 115 patient specimens with troponin levels ranging from 2-100466 ng/L. Results. . Th e between-method comparison of AccuTnI+3 and hs-cTnI on DXI 800 showed a good correlation with the slope of 1.003, correlation coefficient ffi cient (CC) of 0.9590, and bias of-40.65 (-5.16%). However, comparison of AccuTnI+3 and hs-cTnI in 103 patients with troponin less than 20 ng/L, the 99th percentile of the URL for male, showed the slope of 1.325, CC of 0.7462, and bias of 1.91 (21.53%). Th e within-method comparison of hs-cTnI on Access 2 and DXI 800 showed the slope was 1.130 with CC of 0.9915, and bias of 840.4 (10.6%). Further examination of the results revealed that hs-cTnI levels were more comparable at levels less than 200 ng/L, with a slope of 1.069, CC of 0.9951, and bias of 2.3 (6.2%). Conclusion. . Th ese data indicate that contemporary cTnI AccuTnI+3 results above the 99th percentile URL are comparable with hs-cTnI results if both are tested on DXI 800, and hs-cTnI results tested on Access 2 and DXI 800 are comparable at levels less than 200 ng/L. Th erefore, to use the Beckman Coulter cTnI assay properly, we suggest the laboratory report cardiac troponins with the assay and instrument names to reduce confusion during results comparison.
引用
收藏
页码:408 / 412
页数:5
相关论文
共 50 条
  • [1] CytogeneticsComparability of Beckman Coulter Access Cardiac Troponin I Assays
    Stanek, Caroline
    Martin, Deirdra
    Lima, Jose
    Cao, Liyun
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2023, 160 : S140 - S141
  • [2] CytogeneticsComparability of Beckman Coulter Access Cardiac Troponin I Assays
    Stanek, Caroline
    Martin, Deirdra
    Lima, Jose
    Cao, Liyun
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2023, 160 : S140 - S141
  • [3] Assessing matrix, interferences and comparability between the Abbott Diagnostics and the Beckman Coulter high-sensitivity cardiac troponin I assays
    Kavsak, Peter A.
    Malinowski, Paul
    Roy, Chantele
    Clark, Lorna
    Lamers, Shana
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (07) : 1176 - 1181
  • [4] A comparison between the different versions of the Beckman coulter cardiac troponin I assay
    Kavsak, P.
    Worster, A.
    Hill, S.
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : 1177 - 1177
  • [5] Comparison of the biosite triage MeterPlus and Abbott iSTAT cardiac troponin I analyzer to the Beckman Coulter DxI troponin I
    Tran, D. V.
    Cembrowski, G. S.
    Revers, C. W.
    Crawford, J. L.
    Zimmer, C. P.
    Simard, S. L.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A215 - A215
  • [6] Analytical and clinical comparison of the Dade Behring Stratus CS and Beckman Coulter Access 2 AccuTnI cardiac troponin I assays.
    Bodor, GS
    Jordan, D
    Grosz, K
    CLINICAL CHEMISTRY, 2002, 48 (06) : A89 - A90
  • [7] Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay
    Lippi, Giuseppe
    Ferrari, Anna
    Gandini, Giorgio
    Gelati, Matteo
    Lo Cascio, Claudia
    Salvagno, Gian Luca
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (01) : 157 - 161
  • [8] Development of a 2nd generation cardiac troponin I assay* for Beckman Coulter's Access® Immunoassay System.
    Roberts, S
    Page, M
    Smith, S
    Todtleben, J
    Asare, C
    Blocki, F
    Binger, D
    Buelt-Gephardt, M
    Chan, S
    CLINICAL CHEMISTRY, 2000, 46 (06) : A79 - A79
  • [9] Degradation of cardiac troponin I in serum complicates comparisons of cardiac troponin I assays
    Shi, QW
    Ling, MF
    Zhang, XC
    Zhang, MY
    Kadijevic, L
    Liu, SG
    Laurino, JP
    CLINICAL CHEMISTRY, 1999, 45 (07) : 1018 - 1025
  • [10] Analytical performance of Beckman Coulter's Access® AccuTnI™ (troponin I) in a multicenter evaluation.
    Uettwiller-Geiger, D
    Wu, AH
    Apple, FS
    Venge, P
    Jevans, AW
    Darte, C
    Roberts, S
    Yu, Y
    Olson, M
    CLINICAL CHEMISTRY, 2001, 47 (06) : A204 - A205