Comparability analysis of the HNT-1P Huvitz non contact tonometer for the measurement of intraocular pressure

被引:0
作者
Montoya, Alicia Carceles [1 ]
Lucas, Carlos Enrique Monera [1 ,2 ]
Jaimes, Claudia Patricia Tarazona [1 ,2 ]
Valero, Daniel Romero [1 ,2 ]
Martinez, Alejandro Moya [2 ,3 ]
Toldos, Jose Juan Martinez [1 ]
机构
[1] Gen Univ Hosp Elche, Ophthalmol Dept, C/Camino Almazara,11, Alicante 03203, Spain
[2] Miguel Hernandez Univ Elche, Alicante, Spain
[3] Gen Univ Hosp Elche, Biostat, FISABIO, Alicante, Spain
关键词
Glaucoma; non-contact tonometer; intraocular pressure; goldmann applanation tonometer; DYNAMIC CONTOUR TONOMETRY; REBOUND TONOMETRY; APPLANATION;
D O I
10.1177/11206721241263624
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the diagnostic validity of the HNT-1P non-contact tonometer (Huvitz) as a tool for accurately measuring intraocular pressure (IOP) in patients with healthy eyes, compared to the Goldmann applanation tonometer (GAT), which is the Gold Standard method for measurement of IOP. Methods Observational, descriptive, transversal study using 148 eyes of 74 healthy patients without a diagnosis of glaucoma or other ophthalmological diseases. Three measurements of IOP were taken in each eye, using three tonometers: HNT-1P, ICR100, and GAT. The median IOP (quartiles) and mean IOP (SD) its statistical significance were calculated, and comparisons were made between the mean and median IOP values found in three groups: GAT-HNT, GAT-ICR, and HNT-ICR. The difference in mean and median IOP was analyzed in each of the three study groups, and its statistical significance and concordance correlation coefficient (CCC) were calculated. Results The median IOP with HNT-1P was statistically significantly lower than the median IOP with GAT, (1.1 mmHg, p < 0.001). The median IOP with HNT-1P was also lower than the median IOP with ICR100. As an additional result, the median IOP with GAT was lower than the median IOP with ICR. The CCC was moderate for HNT-ICR (0.72) and low for GAT-HNT and GAT-ICR (0.43 and 0.38, respectively). Conclusions HNT-1P (Huvitz) provides statistically significantly lower IOP values than those obtained with GAT. HNT-1P could be used for screening of ocular hypertension in postoperative patients. The IOP measurement obtained with HNT-1P should be confirmed with GAT. HNT-1P yields lower IOP values than those obtained with ICR.
引用
收藏
页码:544 / 550
页数:7
相关论文
共 32 条
[31]   Non-Contact Intraocular Pressure Measurement Method using Relation between Deformed Cornea and Reflected Pneumatic Pressure [J].
Hyung Jin Kim ;
Young Ho Seo ;
Byeong Hee Kim .
International Journal of Precision Engineering and Manufacturing, 2018, 19 :737-744
[32]   Long Non-coding RNA MALAT1 Alleviates the Elevated Intraocular Pressure (Eiop)-induced Glaucoma Progression via Sponging miR-149-5p [J].
Wang, Linling ;
Gong, Jin ;
Wang, Junling ;
Dan, Jing ;
Wang, Ping .
CURRENT EYE RESEARCH, 2021, 46 (06) :903-911