Breathing mode assessment with thermography: a pilot study

被引:0
作者
Telson, Yasmim Carvalho [1 ]
Furlan, Renata Maria Moreira Moraes [2 ]
Ferreira, Rafael Augusto Magalhaes [3 ]
Porto, Matheus Pereira [3 ]
Motta, Andrea Rodrigues [2 ]
机构
[1] Univ Fed Minas Gerais UFMG, Fac Med, Programa Posgrad Ciencias Fonoaudiol, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais UFMG, Dept Fonoaudiol, Ave Prof Alfredo Balena,190,sala 251, BR-30130100 Belo Horizonte, MG, Brazil
[3] Univ Fed Minas Gerais UFMG, Dept Engn Mecan, Belo Horizonte, MG, Brazil
关键词
Thermography; Speech Language and Hearing Sciences; Respiration Mouth Breathing; Nose; Mouth; INFRARED THERMOGRAPHY;
D O I
10.1590/2317-1782/20232022323
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: To present a method for analyzing breathing modes with infrared thermography. Methods: This exploratory cross-sectional study used 38 thermal images of inspiration and expiration with nasal breathing and simulated mouth breathing in four nasal breathers without respiratory complaints. Three different data selection forms (line, rectangle, and ellipse) were used to extract the minimum, mean, and maximum temperatures of the regions of interest (nose and mouth) using the FLTR Tools (R) (R) software. Results: Among the three selection forms, there was greater temperature variability obtained with the line, revealing limitations in this measurement. There were no differences between the rectangle and ellipse values, showing that both selection forms present similar temperature extraction results. The comparison results between nose and mouth temperatures during inspiration and expiration indicated a statistically significant difference between all measurements, except for mean inspiration temperatures with the rectangle and ellipse. The breathing mode can be distinguished in both inspiration and expiration when using mean mouth temperatures with the rectangle and ellipse. Conclusion: Breathing modes should be assessed based on mean mouth temperatures during inspiration, using the ellipse.
引用
收藏
页数:10
相关论文
共 20 条
[1]  
Chrzanowski K., 2010, Testing Thermal Imagers
[2]  
Costa Mariana da, 2015, Rev. CEFAC, V17, P864, DOI [10.1590/1982-021620158614, 10.1590/1982-021620158614]
[3]  
Fei J, 2009, LECT NOTES COMPUT SC, V5762, P1084
[4]   Nasal airflow and thoracoabdominal motion in children using infrared thermographic video processing [J].
Goldman, Luis J. .
PEDIATRIC PULMONOLOGY, 2012, 47 (05) :476-486
[5]   New concept using Passive Infrared (PIR) technology for a contactless detection of breathing movement: a pilot study involving a cohort of 169 adult patients [J].
Hers, V. ;
Corbugy, D. ;
Joslet, I. ;
Hermant, P. ;
Demarteau, J. ;
Delhougne, B. ;
Vandermoten, G. ;
Hermanne, J. P. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (05) :521-529
[6]   Synergetic use of thermal and visible imaging techniques for contactless and unobtrusive breathing measurement [J].
Hu, Meng-Han ;
Zhai, Guang-Tao ;
Li, Duo ;
Fan, Ye-Zhao ;
Chen, Xiao-Hui ;
Yang, Xiao-Kang .
JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (03)
[7]   The Use of Infrared Thermal Imaging to Determine Functional Nasal Adequacy: A Pilot Study [J].
Jiang, Sydney ;
Chan, Jason ;
Stupak, Howard D. .
OTO OPEN, 2021, 5 (03)
[8]  
Kastl KG, 2009, RHINOLOGY, V47, P89
[9]   Development of a baby friendly non-contact method for measuring vital signs: first results of clinical measurements in an open incubator at a Neonatal Intensive Care Unit [J].
Klaessens, John H. G. M. ;
van den Born, Marlies ;
van der Veen, Albert ;
Sikkens-van de Kraats, Janine ;
van den Dungen, Frank A. M. ;
Verdaasdonk, Rudolf M. .
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII, 2014, 8935
[10]   Dynamic nasal infrared thermography in patients with nasal septal perforations [J].
Lindemann, Joerg ;
Wiesmiller, Kerstin ;
Keck, Tilman ;
Kastl, Konrad .
AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2009, 23 (05) :471-474