Assessment by the Scheimpflug imaging system of corneal clarity and anterior segment properties in rosacea patients

被引:0
|
作者
Bozali, Erman [1 ]
Yeter, Duygu Yalinbas [1 ]
Tosun, Mustafa [2 ]
Apa, Anil Selim [3 ]
机构
[1] Cumhuriyet Univ, Dept Ophthalmol, Fac Med, Sivas, Turkiye
[2] Cumhuriyet Univ, Dept Dermatol, Fac Med, Sivas, Turkiye
[3] Minist Hlth Isparta City Hosp, Dept Cardiol, Isparta, Turkiye
关键词
Cornea; Corneal wavefront aberrations; Densitometry; Dry eye syndrome; Rosacea; OCULAR ROSACEA; DENSITOMETRY; CLASSIFICATION;
D O I
10.1016/j.abd.2023.07.005
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Objective: To evaluate the effects of rosacea on ocular surface changes such as alterations in dry eye parameters, corneal densitometry, and aberrations, in comparison with healthy controls. Methods: A total of 88 eyes of 44 patients diagnosed with rosacea and 88 eyes of 44 healthy controls were enrolled in this cross-sectional study. All participants underwent a comprehensive dermatologic and ophthalmic examination and Tear Break-Up Time (TBUT) and Schirmer-1 tests were performed. The rosacea subtype and Demodex count and OSDI scores of all participants were recorded. Corneal topographic, densitometric, and aberrometric measurements were obtained using the Scheimpflug imaging system. Results: The mean age of the 44 patients was 41.2 +/- 11.0 years of whom 31 (70.5%) were female. The mean TBUT and Schirmer-1 test values were significantly decreased and OSDI scores were significantly increased in the rosacea group compared to healthy controls (p < 0.01 for all). The most common subtype of rosacea was erythematotelangiectatic rosacea (70.4%). The severity grading of rosacea revealed that 18 (40.9%) patients had moderate erythema. The median (min-max) Demodex count was 14.0 (0-120) and the disease duration was 24.0 (5-360) months. The comparison of the corneal densitometry values revealed that the densitometry measurements in all concentric zones, especially in central and posterior zones were higher in rosacea patients. Corneal aberrometric values in the posterior surface were also lower in the rosacea group compared to healthy controls. The topographic anterior chamber values were significantly lower in the rosacea group.
引用
收藏
页码:513 / 519
页数:7
相关论文
共 50 条
  • [31] Anterior segment parameters in normal dogs using the Pentacam® HR Scheimpflug system
    Wolfel, Allison E.
    Pederson, Samantha L.
    Cleymaet, Allison M.
    Hess, Ann M.
    Freeman, Kate S.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (05) : 683 - 694
  • [32] Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry
    Soleimani, Mohammad
    Hashemi, Hassan
    Mehravaran, Shiva
    Khabazkhoob, Mohdi
    Emamian, Mohammad Hassan
    Shariati, Mohammad
    Fotouhi, Akbar
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (04) : 510 - 514
  • [33] Repeatability, Reproducibility, and Agreement Between Three Different Scheimpflug Systems in Measuring Corneal and Anterior Segment Biometry
    Hernandez-Camarena, Julio C.
    Chirinos-Saldana, Patricia
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    de la Mota, Angie
    Jimenez-Corona, Aida
    Graue-Hernandez, Enrique O.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (09) : 616 - U44
  • [34] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Wei Lou
    Wei Du
    Haiying Jin
    Ying Hu
    BMC Ophthalmology, 22
  • [35] Comparison of Scheimpflug and Anterior Segment Optical Coherence Tomography Imaging Parameters for Japanese Patients With Fuchs Endothelial Corneal Dystrophy With and Without TCF4 Repeat Expansions
    Maeno, Sayo
    Oie, Yoshinori
    Koto, Ryota
    Nishida, Nozomi
    Yamashita, Arisa
    Yoshioka, Michika
    Kai, Chifune
    Soma, Takeshi
    Koh, Shizuka
    Yoshihara, Masahito
    Kawasaki, Ryo
    Jhanji, Vishal
    Nakamori, Masayuki
    Tsujikawa, Motokazu
    Nishida, Kohji
    CORNEA, 2024, 43 (07) : 805 - 811
  • [36] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Lou, Wei
    Du, Wei
    Jin, Haiying
    Hu, Ying
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [37] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    Yu, A-Yong
    Shao, Hui
    Pan, Anpeng
    Wang, Qinmei
    Huang, Zixu
    Song, Benhao
    McAlinden, Colm
    Huang, Jinhai
    Chen, Sisi
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [38] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    A-Yong Yu
    Hui Shao
    Anpeng Pan
    Qinmei Wang
    Zixu Huang
    Benhao Song
    Colm McAlinden
    Jinhai Huang
    Sisi Chen
    BMC Ophthalmology, 20
  • [39] Anterior-segment imaging for assessment of glaucoma
    Ursea, Roxana
    Silverman, Ronald H.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (01) : 59 - 74
  • [40] Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism
    Muzyka-Wozniak, Maria
    Oleszko, Adam
    Grzybowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)