Evolution of dose distribution for a 125I eye plaque using MCNPX and Plaque Simulator software

被引:0
|
作者
Poorbaygi, Hosein [1 ,2 ]
Sardari, Elham [2 ]
Aghamiri, Seyed Mahmoud Reza [2 ]
Sheibani, Shahab [1 ]
Arjmand, Mojtaba [3 ]
Moradi, Somayeh [1 ]
Ghassemi, Fariba [3 ]
机构
[1] Radiat Applicat Res Sch Nucl Sci & Technol, Tehran, Iran
[2] Shahid Beheshti Univ, Dept Radiat Med, Tehran, Iran
[3] Farabi Eye Hosp, Ocular Oncol Serv, Tehran, Iran
来源
PRECISION RADIATION ONCOLOGY | 2024年 / 8卷 / 02期
关键词
I-125; seed; dosimetry calculation; Eye plaque; Monte Carlo N-Particle eXtended (MCNPX); treatment planning system; TREATMENT PLANNING SYSTEM; OCULAR MELANOMA; UVEAL MELANOMA; BRACHYTHERAPY; DOSIMETRY; PD-103; ENUCLEATION; AAPM;
D O I
10.1002/pro6.1231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Eye plaque radiation therapy is the treatment of choice for small- and medium-sized choroidal melanomas. This study investigated the dose distribution around eye plaques containing I-125 seeds to treat ocular melanoma using Monte Carlo N-Particle eXtended (MCNPX) and Plaque Simulator (PS) software. Methods: Dosimetry evaluation and comparison of the resulting isodose curves for I-125 COMS plaques were performed using the MCNPX code. The isodose curves and dose distributions were calculated using PS treatment planning for a I-125 COMS plaque. Results: In the validation, the maximum relative difference between the results of this study and those reported in other literature was approximately 9%-10% for the COMS plaques. The dose distributions of MCNPX were lower than those of PS with a relative difference of approximately 27.7%-35.4%. The dose distribution may differ depending on the I-125 source spectra and seed design used in the two methods. In addition, the dose algorithm used in PS made a major contribution to the relative differences between the results. Conclusion: The PS did not provide accurate details of dose distribution near the surface of the plaque insert. The source parameters used in each program should be studied more carefully to determine the source of the differences in the estimated dose values.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [21] Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom
    Lesperance, Marielle
    Inglis-Whalen, M.
    Thomson, R. M.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [22] I-125 eye-plaque seed economics: To re-use or to not re-use? A single institutional cost savings analysis of re-using I-125 radioactive seeds for eye-Plaque brachytherapy
    Cappelli, Louis
    Emrich, Jacqueline
    Komarnicky-Kocher, Lydia
    Vinogradskiy, Yevgeniy
    Mourtada, Firas
    BRACHYTHERAPY, 2024, 23 (04) : 463 - 469
  • [23] Radiation complications and tumor control after 125I plaque brachytherapy for ocular melanoma
    Jensen, AW
    Petersen, IA
    Kline, RW
    Stafford, SL
    Schomberg, PJ
    Robertson, DM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01): : 101 - 108
  • [24] Measured, calculated, and egs_brachy I-125 dose distributions in a gold plaque for retinoblastoma treatment
    Trauernicht, Christoph J.
    van Eeden, Dete
    du Plessis, Frederik C. P.
    MEDICAL PHYSICS, 2022, 49 (09) : 6183 - 6194
  • [25] Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom
    Lesperance, Marielle
    Martinov, M.
    Thomson, R. M.
    MEDICAL PHYSICS, 2014, 41 (03)
  • [26] Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
    Taherparvar, Payvand
    Fardi, Zeinab
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 55 (02) : 86 - 95
  • [27] Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources
    Meigooni, Ali S.
    Luerman, Christine M.
    Sowards, Keith T.
    MEDICAL PHYSICS, 2009, 36 (04) : 1452 - 1458
  • [28] Novel application of 3D printing in brachytherapy using MED610 3D printed insert for I-125 ROPES eye plaque
    Sim, L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 863 - 870
  • [29] Long-term visual acuity outcomes in patients with uveal melanoma treated with 125I episcleral OSU-Nag plaque brachytherapy
    Wisely, C. Ellis
    Hadzialnnetovic, Mersiha
    Reem, Rachel E.
    Hade, Erinn M.
    Nag, Subir
    Davidorf, Frederick H.
    Martin, Douglas
    Cebulla, Colleen M.
    BRACHYTHERAPY, 2016, 15 (01) : 12 - 22
  • [30] Treatment plan optimization and robustness of 106Ru eye plaque brachytherapy using a novel software tool
    Heilemann, Gerd
    Fetty, Lukas
    Dulovits, Martin
    Blaickner, Matthias
    Nesvacil, Nicole
    Georg, Dietmar
    Dunavoelgyi, Roman
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 (01) : 119 - 124