Evolution of dose distribution for a 125I eye plaque using MCNPX and Plaque Simulator software

被引:0
|
作者
Poorbaygi, Hosein [1 ,2 ]
Sardari, Elham [2 ]
Aghamiri, Seyed Mahmoud Reza [2 ]
Sheibani, Shahab [1 ]
Arjmand, Mojtaba [3 ]
Moradi, Somayeh [1 ]
Ghassemi, Fariba [3 ]
机构
[1] Radiat Applicat Res Sch Nucl Sci & Technol, Tehran, Iran
[2] Shahid Beheshti Univ, Dept Radiat Med, Tehran, Iran
[3] Farabi Eye Hosp, Ocular Oncol Serv, Tehran, Iran
来源
PRECISION RADIATION ONCOLOGY | 2024年 / 8卷 / 02期
关键词
I-125; seed; dosimetry calculation; Eye plaque; Monte Carlo N-Particle eXtended (MCNPX); treatment planning system; TREATMENT PLANNING SYSTEM; OCULAR MELANOMA; UVEAL MELANOMA; BRACHYTHERAPY; DOSIMETRY; PD-103; ENUCLEATION; AAPM;
D O I
10.1002/pro6.1231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Eye plaque radiation therapy is the treatment of choice for small- and medium-sized choroidal melanomas. This study investigated the dose distribution around eye plaques containing I-125 seeds to treat ocular melanoma using Monte Carlo N-Particle eXtended (MCNPX) and Plaque Simulator (PS) software. Methods: Dosimetry evaluation and comparison of the resulting isodose curves for I-125 COMS plaques were performed using the MCNPX code. The isodose curves and dose distributions were calculated using PS treatment planning for a I-125 COMS plaque. Results: In the validation, the maximum relative difference between the results of this study and those reported in other literature was approximately 9%-10% for the COMS plaques. The dose distributions of MCNPX were lower than those of PS with a relative difference of approximately 27.7%-35.4%. The dose distribution may differ depending on the I-125 source spectra and seed design used in the two methods. In addition, the dose algorithm used in PS made a major contribution to the relative differences between the results. Conclusion: The PS did not provide accurate details of dose distribution near the surface of the plaque insert. The source parameters used in each program should be studied more carefully to determine the source of the differences in the estimated dose values.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [1] Monte Carlo dosimetry of the eye plaque design used at the St. Erik Eye Hospital for 125I brachytherapy
    Karlsson, Mattias
    Nilsson, Josef
    Lundell, Marie
    Tedgren, Asa Carlsson
    BRACHYTHERAPY, 2014, 13 (06) : 651 - 656
  • [2] Treatment planning considerations for 125I eye plaque brachytherapy
    Miguel, David
    Maria de Frutos, Jesus
    Lopez-Lora, Francisco
    Alonso, Pilar
    Diezhandino, Patricia
    Antonia Saornil, Maria
    Garcia, Ciro
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (03) : 280 - 284
  • [3] Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy
    Thomson, R. M.
    Taylor, R. E. P.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2008, 35 (12) : 5530 - 5543
  • [4] 125I plaque brachytherapy for anterior uveal melanomas
    L Lumbroso-Le Rouic
    M Charif Chefchaouni
    C Levy
    C Plancher
    R Dendale
    B Asselain
    S Solignac
    A Mazal
    L Desjardins
    Eye, 2004, 18 : 911 - 916
  • [5] 125I plaque brachytherapy for anterior uveal melanomas
    Lumbroso-Le Rouic, L
    Chefchaouni, MC
    Levy, C
    Plancher, C
    Dendale, R
    Asselain, B
    Solignac, S
    Mazal, A
    Desjardins, L
    EYE, 2004, 18 (09) : 911 - 916
  • [6] COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs
    Melhus, Christopher S.
    Rivard, Mark J.
    MEDICAL PHYSICS, 2008, 35 (07) : 3364 - 3371
  • [7] Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
    Zimmermann, Leonard W.
    Amoush, Ahmad
    Wilkinson, Douglas A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 226 - 239
  • [8] Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy with various seed models
    Thomson, R. M.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2010, 37 (01) : 368 - 376
  • [9] A comprehensive dosimetric comparison between 131Cs and 125I brachytherapy sources for COMS eye plaque implant
    Zhang, Hualin
    Martin, Douglas
    Chiu-Tsao, Sou-Tung
    Meigooni, Ali
    Thomadsen, Bruce R.
    BRACHYTHERAPY, 2010, 9 (04) : 362 - 372
  • [10] I-125 ROPES eye plaque dosimetry: Validation of a commercial 3D ophthalmic brachytherapy treatment planning system and independent dose calculation software with GafChromic® EBT3 films
    Poder, Joel
    Corde, Stephanie
    MEDICAL PHYSICS, 2013, 40 (12)