Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study

被引:1
|
作者
Su, Shi [1 ,2 ]
Hu, Jiahao [1 ,2 ]
Ding, Ye [1 ,2 ]
Zhang, Junhao [1 ,2 ]
Lau, Vick [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
brain; magnetic resonance angiography; MRI; neck; noncontrast enhancement; time-of-flight; ultra-low-field; THIN SLAB ACQUISITION; MR-ANGIOGRAPHY; NOISE-RATIO; TOF-MRA; DISEASE; VOLUME;
D O I
10.1002/nbm.5213
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents. The preliminary feasibility of TOF MRA at 0.05 T was demonstrated for the first time despite the extremely low MR signal. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. image
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer
    Vesanen, Panu T.
    Nieminen, Jaakko O.
    Zevenhoven, Koos C. J.
    Dabek, Juhani
    Parkkonen, Lauri T.
    Zhdanov, Andrey V.
    Luomahaara, Juho
    Hassel, Juha
    Penttila, Jari
    Simola, Juha
    Ahonen, Antti I.
    Makela, Jyrki P.
    Ilmoniemi, Risto J.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (06) : 1795 - 1804
  • [42] Hypertension Correlates With Lenticulostriate Arteries Visualized by 7T Magnetic Resonance Angiography
    Kang, Chang-Ki
    Park, Chan-A
    Lee, Hyon
    Kim, Sang-Hoon
    Park, Cheol-Wan
    Kim, Young-Bo
    Cho, Zang-Hee
    HYPERTENSION, 2009, 54 (05) : 1050 - 1056
  • [43] Comparison of 1.5 and 3.0 T for Contrast-Enhanced Pulmonary Magnetic Resonance Angiography
    Londy, Frank Joseph
    Lowe, Suzan
    Stein, Paul D.
    Weg, John G.
    Eisner, Robert L.
    Leeper, Kenneth V.
    Woodard, Pamela K.
    Sostman, H. Dirk
    Jablonski, Kathleen A.
    Fowler, Sarah E.
    Hales, Charles A.
    Hull, Russell D.
    Gottschalk, Alexander
    Naidich, David P.
    Chenevert, Thomas L.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2012, 18 (02) : 134 - 139
  • [44] SQUID-sensor-based ultra-low-field MRI calibration with phantom images: Towards quantitative imaging
    Dabek, Juhani
    Vesanen, Panu T.
    Zevenhoven, Koos C. J.
    Nieminen, Jaakko O.
    Sepponen, Raimo
    Ilmoniemi, Risto J.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 22 - 31
  • [45] 3-T Magnetic Resonance Angiography in Primary Angiitis of the Central Nervous System
    Cosottini, Mirco
    Canovetti, Silvia
    Pesaresi, Ilaria
    Desideri, Ilaria
    Pizzanelli, Chiara
    Catarsi, Eleonora
    Puglioli, Michele
    Tavoni, Antonio
    Bonuccelli, Ubaldo
    Bartolozzi, Carlo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 493 - 498
  • [46] The assessment of lenticulostriate arteries originating from middle cerebral artery using ultra high-field magnetic resonance time-of-flight angiography
    Grochowski, Cezary
    Krukow, Pawel
    Jonak, Kamil
    Stepniewski, Andrzej
    Wawrzycki, Konrad
    Maciejewski, Ryszard
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 68 : 262 - 265
  • [47] Preliminary study of hemodynamics in human carotid bifurcation by computational fluid dynamics combined with magnetic resonance angiography
    Xue, Yunjing
    Gao, Peyi
    Lin, Yan
    Dai, Chengbo
    ACTA RADIOLOGICA, 2007, 48 (07) : 788 - 797
  • [48] Evaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T
    Manson, Eric Naab
    Mumuni, Abdul Nashirudeen
    Inkoom, Stephen
    Shirazu, Issahaku
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01)
  • [49] Numerical study of ultra-low field nuclear magnetic resonance relaxometry utilizing a single axis magnetometer for signal detection
    Vogel, Michael W.
    Vegh, Viktor
    Reutens, David C.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [50] Toward a magnetic resonance electrical impedance tomography in ultra-low field: A direct magnetic resonance imaging method by an external alternating current
    Lee, Seong-Joo
    Shim, Jeong Hyun
    Yu, Kwon Kyu
    Hwang, Seong-min
    Oh, Sangwon
    Hilschenz, Ingo
    Kim, Kiwoong
    APPLIED PHYSICS LETTERS, 2018, 112 (15)